1 Products availableOur product range contains a wide range of Fire Damper, Motorized Fire Damper and Motorized Fire & Smoke Damper
Fire damper is a device installed in an air distribution system or an air transfer opening designed to close automatically upon detection of heat interrupting airflow and thereby restricting the passage of fire in the process. Fire dampers are installed in fire rated walls/barriers/partitions (sleeve required) where the HVAC ductwork penetrates ensuring that their integrity is maintained. The location and installation procedure of fire dampers should be in accordance with the widely accepted and recommended standard, NFPA 90A Standard for the installation of Air-Conditioning.
Airmasterfire damper is developed with the intention of maximizing occupants safety.
Construction:
Frame:High quality galvanized Iron Sheet of 1.6mm thickness.
Blades:Interlocking type blades roll formed from 1mm thick galvanized steel.
Blade Ramp:Formed from 1.6mm thick galvanized steel with a spring holder.
Springs:2nos. constant force stainless steel springs.
Fusible Links:UL listed fusible links which has fire rating of 165F / 212F.
Description:
Fusible Link:
Vertical: UL Listed 165F / 212F fusible link as standard.
Motorized fire damper
Fire damper is a device installed in an air distribution system or an air transfer opening designed to close automatically upon detection of heat interrupting airflow and thereby restricting the passage of fire in the process. Fire dampers are installed in fire rated walls/barriers/partitions (sleeve required) where the HVAC ductwork penetrates ensuring that their integrity is maintained. The location and installation procedure of fire dampers should be in accordance with the widely accepted and recommended standard, NFPA 90A Standard for the installation of Air-Conditioning.
Airmaster Motorized fire damperis developed with the intention of maximizing occupants safety.
Construction:
Frame:High quality galvanized Iron Sheet of 1.6mm thickness.
Blades:Single skin roll formed from high quality steel sheet of thickness 16 gauge.
Actuator:Fast acting , two positionHoneywell actuator
TRD:Belimo make TRD, 165F temperature rating.
Jamb Seal:Stainless Steel
Description:
Maximum Approved Sizes:
Motorized fire & smoke damper or Combination fire and smoke damper
Fire damper is a device installed in an air distribution system or an air transfer opening designed to close automatically upon detection of heat interrupting airflow and thereby restricting the passage of fire in the process. Fire dampers are installed in fire rated walls/barriers/partitions (sleeve required) where the HVAC ductwork penetrates ensuring that their integrity is maintained. The location and installation procedure of fire dampers should be in accordance with the widely accepted and recommended standard, NFPA 90A Standard for the installation of Air-Conditioning.
Airmaster Motorized fire and smoke damper / Combination fire and smoke damperis developed with the intention of maximizing occupants safety.
Construction:
Frame:High quality galvanized Iron Sheet of 1.6mm thickness.
Blades:Single skin roll formed from high quality steel sheet of thickness 16 gauge.
Actuator:Fast acting , two positionHoneywell actuator
TRD:Belimo make TRD, 165F temperature rating.
Gasket:UL Listed
Description:
Maximum Approved Sizes: