Mega Med

United Arab Emirates

Automatic Four Channels Syringe Pump (MM-SIP004)


Automatic Four Channels Syringe Pump (MM-SIP004)

We are offering automatic four channels syringe pump.features:
four channels, sub-rate injection.four kinds of injection modes: rate mode, time mode, body weight mode, link mode.innovative design of outer appearance gives a strong sense of science and technology.double cpu makes the process of injection safer and more reliable.brand-new stm32 arm-cortex m3 plat-form, optimized circuit design, operation rate more faster and stable.the use of tft color lcd makes the screen display more remarkable.digital menu, easy operation; functions fully meet the clinical demand.ample and user-friendly indicator information; accurate and complete alarm information to ensure safe injection.aluminum alloy base, integrative pump device makes more smooth operation and easier installation and maintenance..



Specifications

Maximum injection rate1500ml/h (Different injectors have different maximum rate.)
Range of flow rate5ml injector: 0.1-100ml/h
10ml injector: 0.1-200ml/h
20ml injector: 0.1-400ml/h
30ml injector: 0.1-600ml/h
50ml injector: 0.1-1500ml/h
Injection increment0.1ml/h
Bolus rate5ml injector: 100ml/h
10ml injector: 200ml/h
20ml injector: 400ml/h
30ml injector: 400-600ml/h
50ml injector: 400-1500ml/h
Injection mode selection1. Rate mode 2. Time mode 3. Body Weight mode
Rate modeSpeed: 0.1-1500ml/h (maximum value depends on the injector specifications)
Time modeTime:1-2000 minutes
Accumulated injection volume: 0.1-999.9ml
Body Weight modeWeight: 0.1-300.0kg
Drug: 0.1-999.9(mg)
Volume: 0.1-999.9ml
Dose: 0.1-9999.9(restricted to unit, drug, solution, weight and injector specification).
Unit: mg/kg/h, ug/kg/min
KVO rateAdjustable range: 0.1ml/h-5.0ml/h (begin the KVO function under the occlusion situation) ; pressing STOP key to cancel the KVO function when it is unnecessary in use.
IP gradeIP21
Injection pressureThe maximum pressure is 0.3Mpa, Occlusion alarm pressure value is 40kPa-160kPa when pressure value is minimum, injection rate is 25ml/h, the longest alarm time is 10 minutes. When pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes.
Preset volume0.1ml-9999.9ml
Preset time0-99 hours, 0-59 minutes
Accumulated injection volume0.1ml-9999.9ml
Accuracy3%
Power supplyAC 100-220V,50/60Hz
BatteryRechargeable lithium polymer battery, 7.4 V, 1600mAh.
Maximum power consumption25VA, running more than 2 hours at the rate of 25ml/h after being fully charged.
Battery chargeWhen syringe pump is connected to AC power, the battery will automatically recharge. (about 8-14 hours to recharge fully.)
FusesT2AL250V-
Displayed informationFlow rate; accumulated injection volume; injector specification; battery capacity; bed No.; AC power indicator, operation indication, etc.
State indication informationStop, inject, bolus, KVO (stop flashing, the other indicators flash by turns.)
Alarm informationnear completion, Over, occlusion, low battery, abnormal 1 (communications failure), abnormal 2 (pump stuck), abnormal 3 (wrong parameter), volume limited alarm, no AC power
Maximum size of the outer shell288x130x122 mm ( lengthx width x height )
Maximum weight<3.0kg
ClassificationClassII, Type BF
Shell materialABS plastic
Operating conditionsEnvironment temperature 5-40, air pressure 80kPa -106kPa,relative humidity 80%
Storage conditionsEnvironment temperature -40-55, air pressure 50kPa -106kPa,relative humidity 95%
Applicable syringes5ml.10 ml.20 ml.30ml.50 ml syringes
Electrical safetyIn accordance with the stipulation of GB9706.1-1995
Applied standardsAccording to the stipulation of YZB/Yue 001-2008