Post Buy Requirement
EA
Dubai, United Arab Emirates
Add Review

Our Products

  1. Power Connectors 5 Products available
  2. Sheet Metal Electrical Enclosure 4 Products available
  3. Cables And Wire Accessories 5 Products available
  4. Others 43 Products available

Other Products / Services

Floodlight

Champ F2MV Mini HID Hazardous Area Floodlights




The Crouse-Hinds series Champ F2MV HID floodlight is a compact, easy-to-install floodlight for use in Class I, Division 2 and Zone 2 hazardous areas.


Manufactured with a Corro-free epoxy coated copper-free aluminum enclosure, stainless steel external hardware and impact-resistant glass, the F2MV is available with the following mogul base HID lamp types and wattages:



  • High pressure sodium (HPS) 50, 70, 100 and 150W

  • Metal halide (MH) 70, 100 and 175W


The F2MV is suitable for marine and wet locations.



Certifications and compliances

NEC and CEC



  • Class I, Division 2, Groups A, B, C, D

  • Class I, Zone 2, Group IIC

  • NEMA Type 4X


UL standards



  • UL844 Hazardous (Divisions Classified) Locations

  • UL2279 Hazardous (Zones Classified) Locations

  • UL1572 Ordinary and Wet Locations, Marine Outside Type


CSA standards



  • C22.2 No. 137

  • CAN/CSA-E79 Series


IEC standard



  • 60079-15




Design features








  • Small, compact size easy to install and maintain

  • 40C and 55C ambient suitability addresses high ambients common in industrial facilities

  • Low ambient capability to -40C perfect for colder climates

  • Heavy duty, copper-free aluminum enclosure with epoxy coating and stainless steel hardware provides a robust design with industrial grade construction and corrosion resistance

  • Continuous silicone gasketing ensures wet and marine locations integrity

  • Stainless steel tether chain and captive cover screws secure cover to housing ensures ease of maintenance

  • Trunnion (yoke) mount design standard construction provides the greatest mounting flexibility; can be mounted vertically (wall), horizontally (rooftop or floor) or any angle in between

  • Requires only two bolts to mount simplifies installation

  • Heat- and impact-resistant tempered glass lens provides exceptional stability

  • Shock-absorbing mogul base lamp socket cushions lamp; improves lamp life in harsh environments

  • 3-axis resonance withstand and UL844 vibration compliant stands up to the tough jobs

  • Precision formed aluminum reflector superior beam control, distribution and efficiency

  • NEMA 7x6 floodlight pattern with lamp orientation base down the ideal light distribution for industrial applications

  • Multi-tap ballasts offering a choice of 120, 208, 240 and 277V; 220V, 50 Hz; 240V, 50 Hz; tri-tap (120, 277 and 347V); and 480V ballasts are also available

  • For use with SFA6 slipfitter adapter and SWB6 wall mount bracket accessories further enhances mounting flexibility

  • Restricted breathing compliance cooler T-numbers for increased hazardous locations suitability









Standard materials








  • Enclosure (housing and lens cover) copper-free aluminum

  • Cover chain and external hardware stainless steel

  • Lens heat- and impact-resistant glass

  • Gaskets silicone rubber

  • Yoke copper-free aluminum

  • Reflector diffused aluminum lighting sheet






View Complete Details

CPMV Wall-Pack Luminaire

  • Housing Material Copper-free aluminum
  • Refractor Lens Material Borosilicate glass
  • Gasket Material Silicone
  • Reflector Material Aluminum light sheet
  • Wire Guard Material Stainless steel
  • External Hardware Material Stainless steel

The Champ-Pak Wall Pack Luminaire is ideal for low-profile mounting in hazardous and industrial environments. In fact, it is suitable for any area with adverse conditions such as dust, dirt, moisture, vibration, high-pressure hose downs, and high thermal ambients. Applications include:



  • Wall mounting or vertical surface mounting where minimal fixture depth is required













Conduit Entries Four 3/4" NPT entries, one on each side, top and bottom (3 plugged); two 1/2" NPT entries on bottom for feed through (1 plugged); consult factory for metric entries
Wattages

High pressure sodium mogul base 50, 70, 100, 150W; metal halide mogul base 70, 100, 150W; compact fluorescent 26, 32, 42, 52, 64, 84W; auxiliary fluorescent 26W; induction 55, 85W






FEATURES




  • Unique compact shallow-profile design mounts virtually anywhere

  • Side-hinged cover with two-screw closing for easy installation and maintenance

  • Gray Corro-free epoxy powder coated two-piece housing provides superior corrosion resistance

  • Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance

  • Glass refractor provides uniform light distribution to eliminate glare

  • Vertical lamp design provides even lamp heat distribution for cooler operation, providing expanded hazardous area suitability

  • Silicone gaskets make luminaire suitable for enclosure Type 4X, marine, and IP66 environments

  • Available in two different conduit entry configurations to permit flexible installation and mounting

  • Four 3/4" NPT hubs, one on each side

  • Two 1/2" NPT hubs on bottom for feed through applications


View Complete Details

Enclosed And Gasketed Incandescent Luminaire

  • Mounting Styles Flush Mount; Surface Mount; Pendant Mount
  • Hub Size 3/4
  • Maximum Wattage Lamp Glass globes: 150W, A23; Polycarbonate: 75W, A33
  • Housing Material Feraloy® iron alloy
  • Guard Material Copper-free aluminum
  • Globe Material Glass
  • Reflector Material Krydon® fiberglass-reinforced polyester
  • Plastic Polycarbonate Globe Optional

V Series Incandescent Luminaires are used:



  • Indoors or outdoors in industrial locations where enclosed and gasketed fixtures are required

  • In tunnels, building entrances and similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem

  • For flush or surface mounting on ceiling or wall, with or without a cast outlet box, pendant or in conduit systems


FEATURES




  • Designed to exclude dirt, moisture and corrosive vapors from the interior of the fixtures and the conduit system

  • Several body styles provide a wide variety of mountings, while all use the same globes, guards and optional accessories

  • Rugged and corrosion-resistant


View Complete Details

Spot Light

  • Wattages Incandescent - 300W, 400W; Quartz Halogen - 500W
  • Hub Size 1/2" NPT
  • Housing Material Cast copper-free aluminum
  • Yoke Material Cast copper-free aluminum
  • Lens Material Clear heat-resistant glass
  • Gasket Material Silicone
  • External Hardware Material Stainless steel

For use in:



  • Marine and watertight requirements

  • High vibration environments

  • Oil and gas exploration and production

  • Surface mining









Available Accessories Narrow Spot Lights Type (NSP*); Wide Floodlight Type (WFL*); SS Guard (G); Handle and Clamp (HDL); 12V Med Floodlight Type 300W (-12); 28V Med Floodlight Type 450W (-28**) *120V only. **10 hour lamp life.


FEATURES


  • Unique lamp suspension system design absorbs vibration to extend lamp life up to 50% longer than competitive brands

  • High temperature silicone gasket provides a watertight seal

  • Adjustable mounting allows 360 horizontal rotation, vertical positioning down 45 and up 90; 60 up with handle option

  • Medium flood with optional narrow or wide beam pattern; lamp included

  • Field replaceable lens and gasket

  • Protective guard available


View Complete Details

Marine Exterior Light

  • Voltage Rated to 250V
  • Mounting Type Recessed wall type
  • Lamp Type Incandescent 40W A-19 max.
  • Lampholder Material Medium base, porcelain
  • Housing Material Cast copper-free aluminum
  • Lens Material Tempered glass
  • Entries Standard units undrilled; up to 1" NPT four way available
  • Available Accessory Surface louver

For use in:



  • Marine and watertight requirements

  • Gangway/walkway steps


FEATURES


  • Low profile flush mount step light

  • 814 models include louver to reduce glare and direct light

  • High temperature silicone gasket provides a watertight seal


View Complete Details

Explosionproof Clock

  • Type Self-starting synchronous (3 watts)
  • Voltage 110VAC 60Hz
  • Hub Size 1
  • Style With sheet steel case, surface mount
  • Body and Cover Material Sheet steel
  • Motor Housing Material Copper-free aluminum

TCH Explosionproof Clocks are used:



  • In oil refinery control rooms, hospital operating rooms, chemical plants, grain handling and processing plants and other similar locations where specific hazardous atmospheres may exist


FEATURES




  • Sheet steel case may be used where environmental conditions are not severe; electric motor and connections are contained in corrosion-resistant enclosure; dials are 13" in diameter; reset knob protrudes from bottom of case

  • Disassembly for installation and maintenance is easily performed; the motor housing is factory sealed, with no external seals required


View Complete Details

Explosionproof Electric Heater

  • Nominal Wattages (kW) 3.0; 5.0; 7.5; 10.0; 15.0; 20.0; 25.0; 30.0; 35.0
  • Voltages 208; 240; 480; 600V
  • Number of Phases 1 or 3
  • Hertz 60 Hz
  • Fan Blade Material Aluminum
  • Core Material Steel with integral aluminum fins
  • Heat Transfer Fluid Long life formulated ethylene glycol and water
  • Cabinet Material 14-gauge steel, epoxy coated with 5 stage pre-treatment including iron phosphate

EXH Explosionproof Electric Heaters are used:



  • For standby heat to prevent process heat loss, or for personnel comfort during maintenance/repair operations

  • For rugged locations including: oil refineries, petrochemical plants, rigs, pumping stations, turbine compressors, pulp and paper mills, coal mines, grain elevators, etc.


FEATURES


  • Split fan guard for easy access to fan

  • Compact design makes handling during installation easy

  • Evacuated cores heat up quickly with even heat distribution

  • Larger models offer greater kilowatt range, providing more economical means to heat large areas

  • Permanently sealed cores improve reliability and make field servicing easier

  • Control box provides easy access for installation and maintenance


View Complete Details

Explosionproof Thermostat

  • Hub Size 3/4
  • Voltages 120/240 VAC (HRC with Honeywell Control); 480 VAC max. (HRC Bimetal)
  • Standard Materials Feraloy® iron alloy (HRC with Honeywell Control); Copper-free aluminum (HRC Bimetal)

HRC Thermostats are used:



  • For heavy duty line voltage to control fan coils, fans, motor starters, valves, contactors and circulator motors in heating and/or cooling systems


HRC Bimetal Thermostats are used:



  • To control heating only, cooling only or ventilation systems in demanding industrial environments


FEATURES



HRC Thermostat with Honeywell Control:



  • A heavy duty snap switch is mounted in the enclosure; the temperature sensitive element is mounted on the external surface of the cover and actuates the switch through a shaft and bearing mechanism

  • An external knob permits temperature setting within calibrated range; the knob is removable to prevent unauthorized adjustment; room ambient is indicated on thermometer at front


HRC Bimetal Thermostat:



  • Bimetal sensing element that is fast acting, reliable and unaffected by altitude

  • Compact, lightweight design makes it easy to install

  • No exposed copper or brass parts for excellent resistance to corrosion

  • Feed-through design for easy installation

  • Durable all aluminum exterior

  • Available for heating only or heating or cooling/ventilation applications


View Complete Details

Circuit Breaker Panelboard

  • Number of Poles 1 or 2
  • Voltages 120/240 VAC max.
  • Trip Ratings 15; 20; 30A
  • Main Lug Sizes 1/0 or 4/0
  • Body, Cover and Hinged Door Material Copper-free aluminum
  • Breaker Operating Handle Material Type 6/6 nylon
  • Interior Parts Material Sheet steel

D2PB Circuit Breaker Panelboards are designed specifically for use:



  • In Class I, Division 2, Groups C, D hazardous areas where flammable vapors or gases may be present due to accident or abnormal locations

  • In damp, wet or corrosive locations

  • Indoors or outdoors in Division 2 areas of petroleum refineries, chemical and petrochemical plants and other process industry facilities


FEATURES






  • Enclosures are of external flange design interior is completely accessible when cover is removed

  • Provided with concealed mounting made possible by having four clearance holes for lag screws or mounting bolts in the back of the enclosure, one in each corner

  • The interior sub-assembly, consisting of a mounting plate, main terminal blocks and circuit breakers, is removable as a complete unit

  • Ample gutter space is provided for ease of field wiring

  • Circuit breakers are contained in compact, individual factory sealed enclosures suitable for Class I, Division 2, Groups C, D hazardous areas

  • Gasketed main cover, which excludes dirt and moisture, is attached to the body with hex head bolts and is removed only when installing the panelboard or making wiring changes; in the center of the main cover is a gasketed hinged door, which provides access only to the circuit breaker operating handles, and is held closed by two quick release catches; the door can be locked by as many as three padlocks to prevent unauthorized operation

  • Tapped conduit openings are provided for main conduit and branch circuits; standard openings can be reduced or plugged to meet most installation requirements

  • Circuit breakers are arranged in two vertical rows and have the circuit numbers marked on the handles; the left row is numbered 1, 3, 5, 7, etc. and the right row 2, 4, 6, 8, etc.; identifying information may be typed on the circuit directory card attached to the inside of the hinged door



View Complete Details

Power Panelboards

  • Panel Sizes B; C; D; F
  • Enclosure Interrupt Rating 10 kAIC - Group B; 65 kAIC - Groups C, D
  • Circuit Breaker Enclosure Body and Cover Material Copper-free aluminum
  • Terminal Housing Material 316L stainless steel or copper-free aluminum
  • Gasket Material Neoprene (cast aluminum enclosure); foam-in-place (stainless steel enclosure)
  • Circuit Breaker Operator Material Size F - copper-free aluminum; all other sizes - non-metallic
  • Chassis Material Silver-plated copper
  • Breather Cap Material Delrin® non-metallic material

PowerPlus Panelboards provide premium factory sealed and value non-factory sealed solutions for the protection and distribution of lighting, power, and heat tracing circuits.


PowerPlus D2D Panelboards are used:



  • For branch power distribution and circuit protection to motors, valves, pumps, lighting, heat tracing, etc.

  • To accommodate up to 100A branch loads (only 3 circuits), balance up to 50A


FEATURES


  • Corrosion-resistant Type 4X breather and drain

  • High quality silver-plated copper bus system

  • OSHA compliant lockout/tagout capability

  • Spring-loaded, quick-release, captive stainless steel cover bolts

  • Optional hinged stainless steel ice/dust shield

  • Integrated steel lifting eye mounted on top side of each panel

  • Manufactured with an external flange design to allow for a wide unobstructed cover opening

  • Superior self-aligning breaker operators designed for both field and factory installation

  • Factory sealed and fully wired for maximum available circuits

  • All terminal blocks come fully wired with each contact numbered for easy connecting of branch entries

  • Heavy gauge 316L stainless steel terminal housings supplied with three removable gland plates

  • High-integrity gasket provides a watertight seal


View Complete Details

Explosionproof Lighting And Heat Tracing Panelboards

  • Panel Sizes B; C; D; X
  • Enclosure Interrupt Rating 10 kAIC - Group B; 65 kAIC - Groups C, D
  • Circuit Breaker Enclosure Body and Cover Material Copper-free aluminum
  • Terminal Housing Material 316L stainless steel or copper-free aluminum
  • Gasket Material Neoprene (cast aluminum enclosure); foam-in-place (stainless steel enclosure)
  • Circuit Breaker Operator Material Non-metallic
  • Chassis Material Silver-plated copper
  • Breather Cap Material Delrin® non-metallic material

PowerPlus Panelboards provide premium factory sealed and value non-factory sealed solutions for the protection and distribution of lighting, power, and heat tracing circuits.


PowerPlus EPL Panelboards are used:



  • For branch power distribution and circuit protection to motors, valves, pumps, lighting, heat tracing, etc.

  • To accommodate up to 100A branch loads (only 3 circuits), balance up to 50A


FEATURES


  • Corrosion-resistant Type 4X breather and drain

  • High quality silver-plated copper bus system

  • OSHA compliant lockout/tagout capability

  • Spring-loaded, quick-release, captive stainless steel cover bolts

  • Optional hinged stainless steel ice/dust shield

  • Integrated steel lifting eye mounted on top side of each panel

  • Manufactured with an external flange design to allow for a wide unobstructed cover opening

  • Superior self-aligning breaker operators designed for both field and factory installation

  • Factory sealed and fully wired for maximum available circuits

  • All terminal blocks come fully wired with each contact numbered for easy connecting of branch entries

  • Heavy gauge 316L stainless steel terminal housings supplied with three removable gland plates

  • High-integrity gasket provides a watertight seal

  • Available with GFI and/or EPD breakers


View Complete Details

Environmental Seal For Conduit

  • Conduit Sizes 1/2" to 6"
  • Conduit Types EMT; IMC; RSC
  • Temperature Range -40ºF to +250ºF (environmental seal); -67ºF to +400ºF (fire seal)
  • Fire Stop Rating 1 hour

Eaton's Crouse-Hinds series Link-Sealis the quick, economical way to seal around conduit in concrete walls, floors and casings. Link-Seal is a modular mechanical seal used for any type of penetration.



FEATURES


  • Saves time and money Link-Seal installs in up to 75% less time than competition products

  • Positive hydrostatic sealing properly installed, Link-Seal is rated at 20 psig (40 feet of head), which exceeds the performance requirements of most applications

  • Environment seals Link-Seal environmental seal is designed for long life and use as a permanent seal; seal elements are specially compounded to resist aging, ozone, sunlight, water and a wide range of chemicals

  • Fire seals for fire protection in floor and wall penetrations, Link-Seal is Factory Mutual approved

  • Resistance to high and low temperatures Link-Seal environmental seal is manufactured from special compounds that resist temperatures from -40F to +250F; Link-Seal fire seal is manufactured from a silicone material that resists temperatures from -67F to +400F

  • Corrosion protection where installation against galvanic corrosion (or electrolysis) is required, Link-Seal provides complete separation pipe and casing; metal-to-metal contact is eliminated

  • Compensates for misalignment Link-Seal allows for some angular and off center conduit conditions and still seals effectively

  • Absorbs shock, sound and vibration this inherent benefit of Link-Seal helps reduce conduit failure due to fatigue and threaded connections


View Complete Details

Cable Sealing Device

  • Cable Diameters 0.250" to 4.5"
  • Block Openings 1 to 11
  • Frame Spaces 6 to 30
  • Accessories Plugs; reducers; closure cover kits; anchors

The Thru-Wall Barrier is designed:



  • To provide a seal for cable/conduit penetrations through masonry, concrete, or steel; to restrict the entrance of contaminants through cable/conduit penetrations into clean areas

  • For use with most types of power, instrument, and control cables as well as conduits


  • FEATURES


    • Few parts required to seal a wide range of diameters of cables or conduits

    • Easy and fast installation, using factory assembled components

    • High degree of flexibility with interchangeable sealing block assemblies and a selection of different sizes of frames

    • One-piece cast malleable iron or steel mounting frame can be cast into concrete during wall construction, grouted in masonry surfaces, or welded into steel bulkheads at any time

    • Retrofit frame allows for easy installation of frame where cables/conduit are already installed

    • Cast keyways in mounting frame align and position sealing block assemblies

    • Specially formulated elastomeric material between cast malleable iron pressure plates protects cable from mechanical damage; provides high pull-out resistance and positive cable separation; expands during fire to seal any voids left by burned cable insulation

    • Interchangeable sealing block assemblies fit all Thru-Wall Barrier mounting frames

    • Assemblies are offered for all cable/conduit outside diameters from 0.250" to 4.500" (6.4 mm to 114.3 mm); cables with diameters less than 0.250" can be accommodated consult factory




View Complete Details

Non-armoured Barrier Gland

  • Protection Type Explosionproof
  • Gland Type Non-armoured barrier
  • Cable Type Non-armoured, marine shipboard, tray and Type P cable (does not terminate the armour)
  • Sizes 3/8" to 4" (NPT); M16 to M110 (Metric)
  • Environmental Rating NEMA 4X; IP66/IP68
  • Standard Material Nickel-plated brass
  • Optional Materials 316L stainless steel; bronze; aluminum

For use with non-armored, marine shipboard, Type P and tray cable, ADE-1FC non-armored barrier glands are installed:



  • To provide a flameproof and weatherproof seal on the outer sheath of the cable

  • To provide an explosionproof compound seal


Please note this product has been revised to comply with IEC 60079-0: 2011 Ed.6.



FEATURES


  • Standard material is nickel-plated brass for superior corrosion resistance

  • Provides a flameproof and weatherproof seal on outer sheath of cable

  • Provides explosionproof compound seal (denoted by red back nut) on conductors

  • Deluge boot provides enhanced protection from water ingress

  • TSC compound suitable for use in operating temperatures -60C to +80C (UL marine -25C to +40C)

  • Available with metric or NPT threads


View Complete Details

IEC Conduit Outlet Box

  • Material Light alloy
  • Shapes T and X
  • Hub Sizes 1/2" to 2"
  • Depths Shallow (C30) and deep (C31)
  • Cover Threads 16 pitch
  • IP Rating IP67

Designed for use in IEC electrical systems, C30 and C31 conduit outlet boxes are installed within hazardous areas to:



  • Provide protection against exterior explosion where acetylene, hydrogen and hazardous gases are present

  • Protect conductors in threaded rigid conduit

  • Act as pull and splice boxes

  • Interconnect lengths of conduit

  • Change conduit direction

  • Provide access to conductors for maintenance and future system changes


FEATURES


  • Taper threaded hubs to provide ground continuity

  • Smooth integral hub bushing to protect conductor insulation when pulling

  • Threaded cover openings

  • Surface covers furnished with boxes

  • Neoprene o-ring gasket and green ground screw are both standard

  • Cover threads are 16 pitch


View Complete Details

Cable Outlet Box

  • Shape 5 threaded hubs with 3 close-up plugs
  • Hub Sizes 1/2"; 3/4"; 1"
  • Material Copper-free aluminum
  • Cover Opening Diameter 5"
  • Cover Threads 16 pitch

GRUE outlet boxes are intended for use within hazardous areas to:



  • Terminate cable connectors

  • Interconnect lengths of conduit

  • Protect conductors in threaded rigid conduit

  • Act as pull and splice boxes

  • Change conduit direction

  • Provide access to conductors for maintenance and future system changes


FEATURES


  • Five threaded hub locations; includes three close-up plugs

  • Tapered threaded hubs to provide ground continuity

  • Internal green ground screw

  • Smooth, rounded integral bushing in each hub protects conductor installation

  • External threaded body and jar style cover provides additional wiring room

  • Cover threads are 16 pitch

  • Cast ears on cover to permit easy removal and tightening

  • Elevated mounting feet, enabling hubs to accept cable connector termination and removal when surface mounted

  • No stand-offs required for mounting feet when installing larger potted barrier glands

  • Neoprene o-ring standard to meet NEMA 4 requirements

  • Copper-free aluminum body and cover provide resistance to corrosive atmospheres

  • Surface cover furnished with box

  • Sealing cover available with 3/4" hub


View Complete Details

ET Elbow And Tee

  • Size 1/2" to 2" (SLB); 1/2" to 4" (LBH); 1/2" to 1-1/2" (LBY); 1/2" to 1" (ET)
  • Material Feraloy iron alloy or copper-free aluminum
  • NEMA Rating 7ABCD, 9EFG

LBH conduit outlet bodies, and SLB and LBY elbows are installed in hazardous areas to:



  • Act as pull outlets

  • Make 90 bends in conduit system, allowing straight pull in either direction

  • Provide access to conductors for maintenance and future system changes


ET short radius tees:



  • Allow single conduit stub up to outlet and device boxes located above or below main conduit runs; eliminates separate feed and return conduits


FEATURES

LBH bodies:



  • Cover openings on an angle, permitting conductors to be pulled straight through hubs from either direction

  • Domed covers to permit easy conductor bends (relieves strain on insulation)

  • Taper threaded hubs with integral bushings


SLB elbows have:



  • Compact overall size and short hubs

  • Taper tapped hubs and integral bushing for standard threaded conduit

  • Covers and gaskets furnished


LBY elbows have:



  • Maximum volume for bends within a compact overall size

  • Screw-on cover for ease of installation and removal

  • Cover opening on an angle, permitting conductors to be pulled straight through either hub

  • Taper threaded hubs and integral bushing for rigid threaded conduit


ET short radius tees have:



  • Compact size and small radius of bend for use in concealed or open conduit systems

  • Particularly suited for use in shallow floors or partitions

  • Taper threaded hubs and integral bushing for rigid threaded conduit


View Complete Details

STL Thread Lubricant

  • Sizes 1-3/4 oz. tube or 8 oz. can (STL); 4 oz. tube (HTL)
  • Temperature Ranges -20ºF to +300ºF (STL); -70ºF to +1800ºF (HTL)

STL thread lubricant is used between any screw thread and its tapped opening, on any rotating shaft threaded or plain, and to inhibit corrosion on any metal-to-metal joint of apparatus and control enclosures.

HTL high temperature lubricant is used on lighting fixture threaded joints and on threaded joints of the enclosures of any heat-producing apparatus or control.


FEATURES



STL is lithium based, anti-galling, and:



  • Is especially effective between parts made of dissimilar metals

  • Is effective and stable from -20F to +300F

  • Maintains grounding continuity; should not be used on exposed current-carrying parts

  • Has excellent adhesion qualities; a liberal application on threaded joints maintains raintightness and inhibits corrosion


HTL is a high temperature, anti-seize, conductive thread lubricant:



  • Effective and stable from -70F to +1800F

  • Prevents seizure, galling, rust, galvanic action

  • Maintains grounding continuity;should not be used on exposed current-carrying parts

  • Effective between parts made of dissimilar metals



View Complete Details

Multi-Gang Device Box

  • Trade Sizes 1/2" to 1"
  • Box Depth 1-11/16" (FS); 2-1/2" (FD)
  • Materials Feraloy iron alloy or copper-free aluminum

Cast device boxes are installed in conduit and cable systems to:



  • Accommodate wiring devices

  • Act as pull boxes for conductors in a conduit system

  • Provide openings to make splices and taps in conductors

  • Provide access to conductors for maintenance and future system changes


FEATURES


  • Available in shallow (FS) or deep (FD) configurations

  • Available in two- and three-gang tandem bodies


View Complete Details

Commercial & Military Aviation Ground Power

Eaton's aviation solutions include Burton and Titan Ground Power plugs, cable assemblies and receptacles. Innovations include glass-filled epoxy carriers and floating contacts (depicted to the left) that extend the service lives of GPU cables and aircraft receptacles by reducing the forces required for mating and demating. Additional Titan Ground Power features include:



  • Adapter contacts were fully functional after applying 2500 pounds of force to the adapter body during reliability testing.

  • Field-replaceable adapters are less than 50% of the cost of aircraft power cable refurbishments.

  • Configuration options include AS7974 qualified cable assemblies.


Over 800 Aviation Ground Power Cables and Receptacles

  • Commercial and military 400Hz, 28VDC, and 270VDC aircraft power cable and receptacle compliances include: AN2551, AN2552, AN3114, AN3430, AS7974, MS3506, MS21379, MS25018, MS25019, MS90328, MS90347, MS90362, MIL-C-81790, and MIL-STD-810F.

  • Aircraft power receptacle configurations include: replaceable pin, airframe mounted, and GPU cart mounted.

  • Aviation ground power cable configurations include: banded, single jacketed, Command Plus, six around one, single point refueling, extension, Y-adapter, jet starting, and single point refueling.

  • Ground power plug and adapter configuraions include: molded, field replaceable, cable saver, plugs with integral switches and indicators, circular, and B1B cable assemblies.

View Complete Details

Micro-Mini AC Dual Key Cordsets

  • Number of Contacts 2-6
  • Voltage Rating 300 VAC
  • Amperage Rating Up to 4A
  • Environmental Rating NEMA 1, 3, 4, 6P, 13; IEC IP68
  • Materials Body: PVC; Coupler: epoxy coated zinc, nylon, or stainless steel
  • Agency Approvals UL Recognized File #E169897

Micro-Mini AC Dual Key products have been specifically designed for low amperage AC control systems and are ideally suited for use in harsh and abusive manufacturing environments.

View Complete Details

ECC Plugs & Receptacles

  • Material Synthetic rubber
  • Number of Contacts 3-12
  • Voltage Rating 600 VAC
  • Amperage Rating Up to 20A
  • Environmental Rating Water-tight

ECC products are a rugged combination of molded-to-cable male plugs and terminal back female receptacles. The receptacle is designed for convenient mounting on standard FS or FD wiring boxes. The plug is furnished molded to various lengths of either cross-link polyethylene or poly vinyl-chloride, 600 volt cable. The ECC connector has found widespread use in applications where operating conditions are demanding, and the utmost in reliability is required due to the high cost of downtime.

View Complete Details

High Voltage Cable Coupling Systems

  • Electrical Ratings 25kV; 700 amp; three-phase
  • AC Withstand 50kV for 1 minute; 40kV for 6 hours
  • Short Circuit 25kA for 0.3 seconds (3 tests, 2 10-minute intervals)
  • Basic Impulse Level 125kV B.I.L.
  • Earth Through Fault 8kA for 0.2 seconds (3 tests, 2 10-minute intervals)
  • Heat Rise 700 amps after 100 cycle contact pre-conditions at 45k over ambient and no more than 10k over the conductor
  • Housing, Adapter and Covers Material Aluminum
  • Contacts and Wire Stems Material Silver-plated copper


Macey 25kV coupling systems are used to supply power to draglines, longwall machines, cranes and other types of equipment.


FEATURES


  • No special installation tools needed

  • Smaller footprint and reduced weight versus the competition

  • Intermatable with other manufacturers' couplers

  • Accommodates a wide range of cable types with entrance fittings, including fiber optic

  • Retained bolting system

  • Low insertion force/high current design

  • Total air displacement no potting of rear body termination point

  • Slip-on stress cone termination module with compression type wire stems eliminates heat or cold shrinking (tyco) sleeves

  • Fully shielded phase compartment eliminates phase to phase faults

  • Louvered contact banding for: higher current capacity; lower contact pressure; improved short circuit performance

  • No altitude de-rating required

  • Slip-on stress cone termination module eliminates strain on contact restraining clip

  • Lockout/tagout feature

  • Four week lead time on standard configuration


View Complete Details

Explosionproof Circuit Breakers

  • Enclosure Sizes Size 1 (15A-100A); size 2 (125A-200A); size 3 (225A-500A)
  • Electrical Rating 3 poles, 600 VAC
  • Breaker Trip Ranges 15A-500A, thermal magnetic (standard); electronic (optional)
  • Materials Body/cover – copper-free aluminum; clamp – anodized copper-free aluminum; external hardware – stainless steel; internal parts – galvanized steel
  • Temperature Range -25°C to 40°C (standard); -50°C to 40°C (optional); -25°C to 60°C (optional)
  • Enclosure AIC Rating 10kAIC at 600V (standard); 65kAIC at 480V and 35kAIC at 600V (optional)
The world's only clamped enclosure for hazardous areas.

One of the biggest challenges with enclosures located in hazardous areas is accessibility. To access internal components for preventative maintenance or troubleshooting, up to 70 bolts have to be loosened and then retightened, leading to extended periods of downtime and safety risks due to improperly torqued or missing bolts.


The clamped EBMX enclosure utilizes patented clamping technology to reduce downtime, increase safety and lower maintenance costs.


Applications:



  • Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining

  • For service entrance, feeder or branch circuit protection for lighting, heating, appliance and motor circuits


FEATURES


  • Patented clamped enclosure design reduces opportunity for missing, stripped or broken bolts

  • Simple clamp actuation for user-friendly access to enter enclosure

  • 65kAIC at 480V enclosure rating for high interrupting capacity applications

  • -50C to +60C temperature range for extreme environments

  • Thermal magnetic and electronic break trip option for short circuit and overcurrent protection

  • Side operated handle provides visual confirmation of proper operator alignment while cover is open and can be padlocked in either "ON" or "OFF" positions for OSHA compliance

  • Neoprene cover gasket provides NEMA 4X protection for hose down applications

  • Maximum wiring room compliance with National Electrical Code requirements allows for easy and safe installation

  • Rugged, corrosion-resistant, cast copper-free aluminum construction provides NEMA 4X protection

  • Semi-clamshell enclosure design, with an external flanged ground joint between body and cover, provides increased access to interior components

  • Minimum enclosure-to-enclosure spacing with little interference between the opened cover and adjacent enclosure

  • Pre-drilled mounting plate for simple breaker installation

  • Detachable tap-on mounting feet

  • Steel brackets supplied standard for lifting during installation

  • Bodies have top and bottom drilled and tapped entries for power and control conduits; removable reducers are supplied standard to accommodate smaller size conduits; all conduit entries are plugged


View Complete Details

Explosionproof Combination Motor Starters

  • Enclosure Sizes Size 2 (NEMA size 0-2); size 3 (NEMA size 3 and 4)
  • Electrical Rating 3 poles, 600 VAC
  • Breaker Trip Ranges 15A-200A, thermal magnetic (standard); electronic (optional)
  • NEMA Starter Sizes NEMA size 1, 2, 3, 4
  • Overload Relays Bi-metallic/thermal (standard); electronic/solid state (optional)
  • Enclosure AIC Rating 10kAIC at 600V (standard); 65kAIC at 480V and 35kAIC at 600V (optional)
  • Materials Body/cover – copper-free aluminum; clamp – anodized copper-free aluminum; external hardware – stainless steel; internal parts – galvanized steel
  • Temperature Range -25°C to 40°C (standard); -50°C to 40°C (optional); -25°C to 60°C (optional)
The world's only clamped enclosure for hazardous areas.

One of the biggest challenges with enclosures located in hazardous areas is accessibility. To access internal components for preventative maintenance or troubleshooting, up to 70 bolts have to be loosened and then retightened, leading to extended periods of downtime and safety risks due to improperly torqued or missing bolts.


The clamped EBMX enclosure utilizes patented clamping technology to reduce downtime, increase safety and lower maintenance costs.


Applications:



  • Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining

  • Across-the-line starting, stopping, speed changing and reversing of polyphased AC induction motors


FEATURES


  • Clamped enclosure significantly reduces time to enter enclosure and reduces opportunity for missing, stripped or broken bolts

  • 65kAIC at 480V enclosure rating for high interrupting capacity applications

  • -50C to +60C temperature range for extreme environments

  • Magnetic, thermal magnetic and electronic break trip options for short circuit and overcurrent protection

  • Bi-metallic and electronic/solid state overload protection options

  • Up to six cover operators for a variety of applications

  • Side operated breaker handle provides visual confirmation of proper operator alignment while cover is open and can be padlocked in either "ON" or "OFF" positions for OSHA compliance

  • Neoprene cover gasket provides NEMA 4X protection for hose down applications

  • Maximum wiring room compliance with National Electrical Code requirements allows for easy and safe installation*

  • Rugged, corrosion-resistant, cast copper-free aluminum construction provides NEMA 4X protection

  • Semi-clamshell enclosure design, with an external flanged ground joint between body and cover, provides increased access to interior components

  • Minimum enclosure-to-enclosure spacing with little interference between the opened cover and adjacent enclosure

  • Pre-drilled mounting plate for simple starter and breaker installation

  • Detachable tap-on mounting feet

  • Steel brackets supplied standard for lifting during installation

  • Bodies have top and bottom drilled and tapped entries for power and control conduits; removable reducers are supplied standard to accommodate smaller size conduits; all conduit entries are plugged


*Standard factory wiring included between the starter and breaker consult factory for any additional wiring requirements.


View Complete Details

Explosionproof Conveyor Belt Alignment Switches

  • Contact Arrangement 2 normally open or 2 normally closed
  • Electrical Ratings 15A, 600VAC max.
  • Enclosure Material Feraloy® iron alloy
  • Bearing and Operating Arm Material Stainless steel with plastic end caps
  • External Corro-free™ Epoxy Powder Coat Optional

AFA/AFAX Conveyor Belt Alignment Switches are used:



  • As emergency or normal "STOP" switch for conveyor belts whenever they become misaligned or run off their tracks due to excessive speed, uneven load, leveling, breakage and/or other problems



  • In steel mills, mining, ore, and coal handling operations, automotive and assembly lines, warehouses, loading docks, and grain loading and handling


FEATURES




  • Furnished with precision switches that provide normally open and normally closed contacts (switches have a snap action mechanism)

  • Housing consists of a center section which can be mounted either vertically or horizontally, and a switch housing with an attached switch operating arm

  • Enclosure has three 1" conduit hubs; cast mounting lugs on 1 1/2" center permit attachment to the web of a standard 3" angle iron

  • Operating arm has 3 1/2" long stainless steel protective roller; approximately 3/4" lateral movement of operating arm actuates switch

  • Spring loaded operating arm will automatically return switch to normal position when belt interference is removed

  • A severe conveyor belt run-off can rotate the operating arm counter-clockwise up to 85 degrees without damage to the switch mechanism

  • Installation of AFA or AFAX unit on either side of a conveyor belt allows approximately 1" or a pre-determined allowable belt misalignment before switch is actuated; a typical installation would include a pair of AFA or AFAX units at each end of the conveyor belt where belt returns



View Complete Details

AFU Addressability Control Switch

  • Description Single end left; single end right; double end
  • Maximum Weight of Unsupported Line or Cable without Actuating Switch 15 or 25 lbs.
  • Total Operating Force Required 25 or 50 lbs.
  • Electrical Ratings 15A, 600 VAC max.
  • Enclosure Material Feraloy iron alloy or copper-free aluminum
  • Plunger Material Stainless steel
  • Loop Material Bronze or copper-free aluminum
  • Indicating Arm Material Steel

AFU Conveyor Belt Switches are used:



  • To provide instant digital monitoring capability to identify emergency situations during conveyor operations

  • As emergency or normal "STOP" switch for conveyor lines, cranes, unloaders, and bulk handling systems

  • In steel mills, mining, ore and coal handling operations, automotive and assembly lines, warehouses and loading docks

  • In the control circuit of magnetic motor starters to shut down motor-driven conveyors or other machinery when switch is actuated


FEATURES


  • Furnished with one or two end units, each containing 2-NO and 2-NC contact arrangements

  • Precision switches provide maintained contact (switches have a snap action mechanism)

  • Multiple conduit hubs (AFU: two 1"); cast mounting lugs on 1-1/2" centers permit attachment to the web of a standard 3" angle iron

  • In installation, the actuating line or cable is connected from a fixed point to the loop on the end unit; a pull on the line of the required operating force and with a total movement of 1/2" actuates the plunger, opens the switch and trips the red painted indicating arm forward, which locks the plunger in the actuated (switch open) position; returning the indicating arm to its normal position resets the mechanism; a typical installation would include single end switch units at each end of the conveyor with double end switch units between

  • Depending on the size and length of line, supports at properly spaced intervals may be necessary to ensure that the line or cable weight alone will not actuate switch

  • Provides instant digital monitoring capability to identify emergency situations during conveyor operations


View Complete Details

Attachable Pendant Pushbutton Station

  • Styles 2-button; 4-button; 6-button; 8-button
  • Cable Diameters .31-.75; .50-.75; .59-.81; .59-.92
  • Body and Cover Material Steel reinforced neoprene
  • Strain Relief and Reinforcement Plate Material Stainless steel
  • Exterior Hardware Material Stainless steel

D2X Attachable Pendant Pushbutton Stations are used:



  • For safe multi-function motor circuit control of: hoists, cranes, machine tools, electromagnets

  • For control applications requiring 2 to 8 functions


FEATURES


  • Safety cushioned neoprene encapsulation protects internal switches and connectors from impact damage and provides extra protection for personnel

  • Stress relief for your cable is built-in; a separate cable grip is not needed

  • Uses Eaton's Crouse-Hinds series ESWP factory sealed contacts suitable for use in Class I, Division 2, Groups B, C, D

  • Switches are rated for 10 amps 600 VAC (NEMA A600)

  • Indicator plates meet OSHA requirements for clear identification of functions; a full set of plates is included with each station

  • Jam-resistant operator buttons are raised flexible diaphragms an integral part of the molded one-piece cover

  • Compact design

  • Safety yellow finish


View Complete Details

DSD-TS Timer

  • Horsepower 1 HP or 2 HP
  • Max. Voltage 120 VAC (for 1 HP); 250 VAC (for 2 HP)
  • Time Configuration Minutes or hours
  • Material Aluminum



  • Provides automatic shut-off for fans, heaters, pumps, lights and other energy-consuming loads in Class I and Class II hazardous areas

  • For use with Eaton's Crouse-Hinds series EDS/EDSC back boxes (single- and two-gang) and EDSCM modular control device bodies (up to nine-gang maximum)


FEATURES


  • Spring wound, mechanical timer switch

  • Copper-free aluminum covers


View Complete Details

Explosionproof Ground Fault Control Station

  • Number of Breakers 1 or 2
  • Number of Poles 1 or 2
  • Milliamp Trip 5 or 30
  • Electrical Ratings GFI, EPD Breakers - 120VAC (single pole); 120/240VAC (two pole) (10, 000 AIC)
  • Body and Cover Material Copper-free aluminum
  • Threaded Barrel, Guard, Collar, and Toggle Operator Material Copper-free aluminum
  • Pushbutton Material Type 6/6 nylon
  • Operating Shaft Material Stainless steel

EGF Explosionproof Ground Fault Control Stations are used:



  • For the additional safety of personnel, and for equipment protection in remote areas


FEATURES


  • Copper-free aluminum construction offers lightweight, corrosion resistance and a long, maintenance-free service life

  • 1 1/4" through feed conduit hubs with 1 1/4"1" reducers for ease of installation

  • Compact, internally flanged enclosure requires minimum installation area

  • Steel mounting feet with electroplate finish for fast, secure, and corrosion-resistant mounting

  • Accepts #14#10 copper wire sizes for application flexibility

  • Push-to-test button and pilot light (with 10, 000 hour incandescent lamp) for easy and constant operational monitoring of unit

  • Cast aluminum circuit breaker operating handle for durability during use

  • EPD breakers for protection of heat tracing circuits


View Complete Details

Explosionproof Static Grounding Indicator

  • Power Consumption 9.8 VA
  • Voltage 120 VAC supply
  • Control Relay Interlocking Contact 15A at 277 VAC; 10A at 600 VAC
  • Switching Impedance Provides 2k ohms or less
  • Enclosure Material Copper-free aluminum with interior and exterior epoxy powder coat
  • Clamp Material Stainless steel
  • Clamp Grip Material Polyvinylchloride dipped
  • Gasket Material Neoprene
Ensuring safe product transfer with automated pump control and static ground verification system.

Provides producers, handlers and manufacturers of combustible materials a safe product transfer solution with low maintenance, simple installation and reliable operational benefits at a competitive price.



FEATURES


  • Static ground verification system provides ground path for static build-up to ensure safe product transfer

  • Integrated control relay allows for safe control of electrically operated pumps or valves, and for energizing remote indicators

  • Stainless steel clamp for grounding connection provides industrial durability, corrosion resistance and increased product lifetime

  • Interior and exterior epoxy powdered paint finish provides superior corrosion resistance inside and out

  • LED pilot lights provide long-lasting visual identification of status of ground connection

  • ECD Type 4X drain protects interior equipment from environmental moisture and condensation, rain water and hose down applications

  • NEMA 4X compact, hose-tight and corrosion-resistant enclosure offers years of service in harsh industrial environments

  • 25 ft. safety fluorescent yellow cord is easily identifiable to ensure safety and reduce tripping hazard

  • Neoprene cover gasket provides a watertight seal to meet UL Type 4 (NEMA 4) requirements

  • Stainless steel hinges are corrosion-resistant while providing safe and easy access to interior of enclosure

  • Waterguard desiccant packet absorbs and removes water/moisture and protects the enclosed equipment when not energized

  • Adjustable mounting feet provide ease of mounting during installation


View Complete Details

Explosionproof Custom Built Control Panel

  • Enclosure Material Copper-free aluminum
  • Hinge Material Stainless steel
  • Number of Device Openings 9; 16; 36; 24; 54; 81; 52; 78; 117
  • NPT Conduit Sizes 1/2"; 3/4"; 1"; 1 1/4"; 1 1/2"; 2"; 2 1/2"; 3"; 3 1/2"; 4"; 5"; 6"
  • Metric Openings M16; M20; M25; M32; M40; M50; M63
  • Available Options ATEX certification; breather and drain; external epoxy finish; internal and external epoxy finish
Globally CertifiedIndividually Customized.

An explosionproof enclosure built to customer-specific needs, allowing for the grouping of control devices for process control in minimum space requirements. Available in a variety of sizes with an unlimited combination of devices, windows and markings, these panels are designed to maximize the efficiency of each unique process.



FEATURES


  • Neoprene cover gasketbetween body and coverprovides NEMA 4, IP66 watertight seal

  • Tap-in mounting feet offer a simple and secure way to mount enclosure, and are replaceable if broken or lost

  • Captive, quick release stainless steel triple lead cover bolts make it easier to get in and out of the enclosure

  • Optional GUB explosionproof glass window is available when you need to see inside

  • Internal and external ground terminations simplify grounding requirements

  • EMP Seriesthe most complete line of devices in the industry (pilot lights, pushbuttons, selector switches, potentiometers)

  • Optional individual device markings to clearly indicate the function of each device (may be added in the field)

  • Optional engraved nameplates

  • Copper-free aluminum construction available with Corro-free epoxy powder coat for additional protection in corrosive atmospheres

  • NPT or metric entries available

  • Internal mounting plate standard

  • Stainless steel hinges


View Complete Details

Explosionproof Barrel Assemblies

  • Assembly Types Short; standard; long
  • Pilot Light Colors Available Red; green; amber; clear; blue

EMP and EMPS Explosionproof Barrel Assemblies for Control Stations:



  • Are primarily for use with hazardous area boxes to assemble special control stations

  • Certain barrel assemblies are the same as those used in complete EMP units and may be utilized as replacements


FEATURES


  • Certain barrel assemblies are the same as those used in complete EMP units and may be utilized as replacements

  • The remainder are primarily for use with hazardous area boxes to assemble special control stations


View Complete Details

IEC AFT Conveyor Belt Ripped/Torn Switche

  • Material Copper-free aluminum
  • Electrical Ratings 10A at 600 VAC; 5A at 250 VDC
  • Mounting 2 x M10 bolts
  • Cable Entry 3 x M20
  • Ambient Temperature -20°C to 70°C

IEC AFT Conveyor Belt Ripped/Torn Switches are used:



  • As an emergency stop switch for torn or ripped conveyor belts in conveyor lines, cranes, unloaders and bulk handling systems

  • In steel mills, mining, ore and coal handling operations, automotive and assembly lines, warehouses and loading docks


FEATURES


  • Switches are positioned on both sides of the conveyor and connected to provide protection for torn or ripped belts

  • Installed near high risk loading points where belt tears typically occur every 300 meters

  • Maintained action utilizes normally open and normally closed contacts to shut down conveyor belt and signal alarm

  • Heavy duty cast enclosure provides protection in harsh and rugged environments


View Complete Details

Limberoller Return Idlers & Bracket


  • Consist of a solid steel shaft completely encapsulated in rubber for a virtually impervious sheath

  • For high impact of heavy duty

  • 3-1/2" diameter


FEATURES


  • Return Idlers LR-106 and LR-307 Series feature sold shaft return idlers with double row ball bearings

  • LR-106 and LR-307 are for high impact of heavy duty

  • LR-107 Series sold shaft return idlers with double row ball bearings

  • Solid steel shaft completely encapsulated in rubber for a virtually impervious sheath

  • Steel hanger and training return brackets for use with LR-106, LR-107, and LR-307 Series

  • Synthetic rubber top mount brackets are for use with LR-106 and LR-107 Series

  • Return idlers feature bearing housings that are slotted so that they will fit in specially designed hanger and support brackets

  • Limberoller return brackets feature hanger, top mount and training styles


View Complete Details

Motor Plug

  • Amperages 30; 60; 100A
  • Styles Style 1 or Style 2
  • Configurations Style 1: 2W 2P, 3W 3P, 4W 4P; Style 2: 2W 3P, 3W 4P
  • Cable Diameters 0.39 to 1.20; 0.50 to 1.45; 0.875 to 1.70
  • Voltage 600VAC/250VDC, 50-400 Hz
  • Mounting Plate Material Feraloy® iron alloy
  • Protective Sleeve Material Copper-free aluminum
  • Back Box Material Copper-free aluminum

ArktiteAPQ Series 30-100A Motor Plugs are used:



  • On portable electric equipment


FEATURES


  • Eliminates problem of storing and protecting a long length of portable cord and plug on portable device

  • Connection to fixed receptacle used as power source is made with cord sets which may be hung on wall, out of the way

  • Cord sets are made up using an APR receptacle at one end and an APJ plug at the other

  • Cord sets may be used singly or connected together to provide longer lengths when needed

  • With spare cord sets on hand, portable equipment may be kept in service while normal cord replacement is being made

  • Where design of portable equipment permits, APQ motor plugs can be attached directly to a sheet metal panel or cabinet

  • May be mounted on AR and AJ back boxes for conduit connection


View Complete Details

Subsea Penetrator

Eaton's subsea penetrators are designed for applications that require maximum pressure protection and minimal maintenance over long-term deployments. An extensive array of solutions includes Burton subsea products and penetrators that were formerly promoted under the Electro-Oceanic name:



  • Standard products available with 2 to 12 conductors ranging from 1/0AWG to 18AWG.

  • Straight and right-angle body configurations available with straight and National Pipe Threads (NPT).

  • Custom penetrators, wiring harnesses, and cable assemblies.


View Complete Details

WLGF Wet Location Covers For Device Box

  • Amperages 15 or 20A
  • Configuration 2P 3W
  • Voltages 125V or 250V
  • Face Plate and Cover Material Die cast copper-free aluminum
  • Cover Hinge Spring Material Stainless steel
  • Cover Screws Material Corrosion-resistant metal
  • Gasket Material WLRS/WLRD - ethylene propylene rubber (EPDM); WLGF - neoprene
  • Standard Finish Copper-free aluminum
WLRS, WLRD and WLGF Wet Location Covers for Device Boxes

WLRS, WLRD and WLGF covers are suitable for use in wet and damp locations (WLGF suitable only when cover is closed).


Use WLRS, WLRD and WLGF:



  • Wherever portable equipment is required

  • In areas where electrical requirements do not exceed medium duty ratings

  • To mount FS and FD single-gang or multi-gang boxes having individual cover openings

  • To mount on most flush device boxes


FEATURES


  • Self-closing spring door assures protection of wiring device at all times, in wet and damp locations

  • One piece EPDM gasket provides environmental protection of wiring device at all times

  • Specially formulated elastomeric gasketing material offers excellent resistance to ozone, weather and temperature extremes of -50F to 260F

  • Die cast, copper-free aluminum construction with aluminum lacquer finish provides maximum corrosion resistance

  • Positive ground path ensured for all exposed metal parts


View Complete Details

Vibrating Horn Signal

  • Type Double projector or single projector
  • Minimum Audibility Rating (dB) at 10' AC - 87 decibels
  • Nominal Voltage 120AC 50/60 Hz
  • Voltage Range ± 10%, -20%
  • Nominal Wattage 18 VA on 120VAC
  • Standard Materials Copper-free aluminum and die cast zinc
  • Standard Finish Gray hammertone enamel

WH Vibrating Horn Signals are used:



  • For code or call signals, or as a general alarm in a signal system that might involve hours of continuous operation

  • In non-hazardous atmospheres of industrial areas such as warehouses, yards, exteriors of buildings, and in-plant areas

  • Mounted on walls or other flat surfaces with projectors aimed in a desired direction

View Complete Details

Status Indicator Light

  • Body Material Alloy (SM87); Corrosion-free GRP (XB11 and XB12)
  • Entries Up to 1 x 1/2" NPT
  • Max. No. of Ways 4 (SM87); 5 (XB11 and XB12)

SM87, XB11 and XB12 Status Lights are the most rugged and reliable status lights for harsh and hazardous applications.


The SM87 SL range is manufactured in marine grade alloy and the XB12 SL in corrosion-free GRP to provide a wide range of status lights to suit your requirements. Applications include:



  • Process status

  • Messaging

  • Alert or emergency condition indication


FEATURES


  • 4-wire monitored connection for supervisory circuits*

  • Marine grade alloy or GRP

  • Pre-wired to customers requirements


View Complete Details

Steady-On Beacon

  • Weight 6.2 lb./2.8 kg.
  • Body Material Glass reinforced polyester
  • Lens Material Glass
  • Cover Screw and Backstrap Material 316 stainless steel
  • Terminals 6 x 14AWG
  • Entries 2 x 1/2" NPT
  • Labels Duty/tag label optional
  • Incandescent 10W incandescent fitted as standard

FB11 UL Steady-On Beacons are UL Listed for Type 3R, 4X and marine installations. Typical industrial and commercial applications include food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, offshore oil rigs, water and filtration plants and chemical plants.


FEATURES


  • Units are UL Listed for Type 3R, 4X and marine installations

  • The steady-on beacons are available for pendant, wall, stanchion and ceiling mounts, and come in six different globe colors

  • Typical industrial and commercial applications include food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, off-shore oil rigs, water and filtration plants and chemical plants

  • The diode polarized steady-on beacon is used in electrically supervised circuitry for life-safety or security applications


View Complete Details

Fire Alarm Emergency Call Point

  • Housing Material Stainless steel or alloy (SM87); Corrosion-free GRP (PB and BG)
  • Entries Up to 4 x 1/2" or 3/4" NPT or up to 4 x 20mm or 25mm (SM87); Up to 4 x 1/2" NPT, M20 (PB and BG)

Fire Alarm or Emergency Call Points have been designed for use in hazardous locations and harsh environmental conditions. They offer:



  • A compact design, activation choices such as pushbutton or break glass, housing color choices and comprehensive worldwide certifications

  • Flexibility - all units accept metric cable or NPT conduit entries

  • Each unit can be custom designed


FEATURES


  • In-line and end-of-line resistors fitted for use in fire activation circuits

  • Optional LED to indicate operation

  • Plastic break glass element availableeasy activation yet safe to touch

  • Corrosion resistant GRPideal for marine applications

  • Retained stainless steel cover screwswont corrode and never lose screws

  • Optional lift flap for protection


View Complete Details

Heat Detector

  • Body Material 316 stainless steel
  • Enclosure Material Exd - LM25 marine grade alloy; Exia/Exem/UL - GRP (anti-static)
  • Cover Screw Material Stainless steel
  • Terminals 6 x 4mm2 (BK6)
  • Entries 2 x M20 ISO (ATEX/Exd/Exe/Exi versions); 2 x 1/2" NPT via adapters (UL version)
  • Weights Exd - 2 kg.; Exia/Exam/UL - 1.1 kg.
  • Labels Optional stainless steel tag and duty labels

HD1 Heat Detectors have been designed for use in hazardous environments. These units are suitable for fire alarm and/or suppression systems in offshore and onshore applications including paint spray booths, flammable material stores, turbine rooms, extract ductwork and other hazardous areas throughout the oil and gas, petrochemical and process industries.



FEATURES


  • Designed for use in hazardous environments

  • Suitable for fire alarm and/or suppression systems in offshore and onshore applications including paint spray booths, flammable material stores, turbine rooms, extract ductwork and other hazardous areas throughout the oil and gas, petrochemical and process industries

  • Comprising a Fenwal rate-compensated detector with all-stainless steel external construction, mounted to either a type SM87 marine grade alloy enclosure (Exd version) or JB10 corrosion-free GRP enclosure (Exia, Exem/UL versions)

  • The contact in the detector CLOSES at alarm temperature


View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Eaton (Eaton)
  • Middle East (Dubai) uae
  • Share us via