Ring Main Unit

igis : ring main unit (rmu)



igisring main unit (rmu) demonstrates a highly innovative and modern design that complements the latest production technology from germany. Igis guarantees highest accuracies and realizes almost 100% gas tightness. Manufactured with the latest filling and testing techniques, igis undoubtedly has a superior performance in the market of sf6 gas insulated ring main units. Igis is a state of the art medium voltage switchgear that not only guarantees high operational safety, but also has a reliable indication of switching positions. The panels are type tested as per iec standard 62271-200


while utilizing the most modern design for ring main units, the glx24 also features the use of the most advanced manufacturing technology world wide. With laser cutting and punching machines from trumf (germany), accuracy is guaranteed; the laser welding machine, also from trumpf, ensures 100% gas tightness, together with advanced filling and testing devices. Fuse holder and circuit breakers peruse the newest the newest in agp process. This makes the glx a world leader in technology.

glx24 has already successfully been type tested in institutes around the world, including kema. Designed for mv network up to 24 kv, power stations, all the important industries, the versatile design of the glx24, in both extendability and compact versions, ensures safe power supply for all.



major technical highlights of rmu



the rmu's tested at short circuit current of 21.5ka-3s & 25ka- 1s, to have better strength against short circuit forces. Microprocessor based laser welding is used for stainless steel gas tank, which is superior to robotic/manual tig welding. This ensures complete leak-tight gas tank for the entire product life of 20 years, ensuring a leakage rate of 0.02% per annam only & being lowest in the market. A state of the art design , which ensures insulation agility worth a partial discharge value less than 4 pf.



application



  • mv network up to 24 kv

  • power stations and industries

  • indoor and outdoor versions

















standard features



























modular compact design fully extensible and flexible
common or single gas tank solution designed for up to 24 kv
easily applicable to outdoor areas extreme compact dimensions: 350 mm x 800 mm x 1380 mm
itp fuse holder itp circuit breaker
top and bottom cable entry designed for intelligent network
environment friendly

View Complete Details

Medium Voltage Switchgear























The Product range includes the following:

TRUMP 1 : Indoor Metal Clad Vacuum Switchgear (3.3kV/6.6kV/11kV)
TRUMP 1 : Outdoor Metal Clad Vacuum Switchgear Kiosk (3.3kV/6.6kV/11kV)
SPARK 1 : Outdoor Porcelain Clad Vacuum Switchgear (3.3kV/6.6kV/11kV)
SPARK 3 : Outdoor Porcelain Clad Vacuum Switchgear (22kV/33kV)

Application

TRUMP 1 - Control & protection of underground cables, transformers, motors and capacitor banks

SPARK 1 & 3 - Control & protection of overhead lines, transformers, motors and capacitor banks


Standard Features























Floor mounting, free standing & simple installation type Extensible on both sides(br>
Fully enclosed design suitable for IP4X and IP5X Compact design and minimal maintenance
Fully compartmentalized design (separate chambers for breaker, bus bar, cable & CT and instruments & relays) Horizontal draw out and horizontal isolation design
Various interlocks and automatic metallic independent safety shutters Suitable for installation in open hot & humid atmosphere
Designed & type tested conforming to standards IS 13118 & IEC 62271-100

View Complete Details

Power System Recorder Type




















TESLA LITEis an economical user-friendly multi-timeframe power system recorder that provides multifunctional recording and event logging with advanced communications. This easy to use multi-time frame recording system records 12AC currents, 6 voltage channels and 38 digital (status) channels and stores 250 recordings in on board memory.

The TESLA LITE records data simultaneously in three time domains: High speed transient fault (seconds), Low speed dynamic swing (minutes)and continuous trend (10 Second to 1 hour intervals). a wide variety of triggers are available to initiate recording

The intuitive TESLA control panel user interface software configures the recorder, retrieves and manages records and displays real time measured values. Control Panel also includes Record graph, a graphical record display and analysis software tool.

These features make TESLA LITE a cost effective independent and complete recording solution for small substations.

Application



  • Complete power system recording for custom applications in smaller substations

  • User- Configurable trend recording

  • Data compression for fast file transfer.


Standard Features












Economical yet complete power system recording for custom applications in smaller substations Easy to use intuitive software
Simultaneous transient fault, dynamic swing and trend recording and event logging Fault location derived from single and calculated currents

View Complete Details

Multi-timeframe Power System Recorder Type























TESLA 4000is an intelligent, state of the art, user-friendly multi-timeframe dynamic power system recorder with advanced Phasor Measurement Unit (PMU) and Continuous Disturbance Recording (CDR) capabilities.

TESLA 4000 is an easy-to-use and cost effective, state of the art, multi-time frame (simultaneous) power system monitoring recorder. The integrated Phasor Measurement Unit (PMU) functionality streams synchrophasor data for wide area monitoring.

The TESLA creates records simultaneously in three time domains - fault (fast), dynamic swing (slow) and trend records and also creates event logs.

The CDR creates continuous records without triggers which together with the fault, swing and trend records provides wide area visibility of system performance. The CDR also creates redundancy in PMU data.With these powerful recording and communication capabilities, the TESLA recording systems provides the most versatile and complete monitoring of power system health.


Application



  • To provide early warning for unstable conditions in power system



  • Improve system planning through real-time state estimation



  • Major load centers, generation facilities and transmission interfaces



  • Easy-to-use settings and analysis software



  • PMU per IEEE C37.118-2005 standard



  • Advanced communication protocols



  • SCADA support with DNP3 and Modbus



  • CDR meets NERC PRC-002 DME standards



  • Remote input modules save on costly wiring runs



  • Lossless data compression for fast file transfer



  • Non-volatile on board flash memory


Standard Features




















IEC 61850 station bus communication with optical ports Wide area swing recording enables system performance analysis
Meets NERC continuous disturbance recording standards with non-volatile on boards flash memory No mechanical moving parts- flash drive eliminates most common mode of failure in recorders. Each Flash drive holds 1000 recorders.
IEEE C37.118 -2005 SynchroPhasor standard Remote input modules up to 1200 meters (4000 feet) away save on costly CT and PT wiring runs.
Smallest footprint among recorders allows easy retrofit and installation Settings and adjustments done outside the box after initial installation avoids outages

View Complete Details

Vacuum Circuit Breaker




















iCBseries comprises embedded pole type vacuum circuit breakers for medium voltage and indoor use. They are suitable for three phase AC operations for 12kV, 17.5kV, 24kV and 36kV and are used for the protection of the electrical equipment in various industries, mining, and especially for medium voltage distribution sub stations, together with suitable air-insulated cubicles.

The iCB used German Technology and is available in complete series for medium voltage and for all commonly used rated currents, from 630A to 4000A, and for rated breaking current up to 40kA.

Application



  • Suitable for 3-phase AC operations for 12kV, 17.5kV, 24kV and 36kV

  • Medium voltage distribution sub stations


Standard Features
















Embedded pole technology protects the circuit breaker from shock and mechanical stress, pollution and condensation The epoxy resin embedding creates a full insulation for the internal electrical circuits
Lifetime of over 30, 000 mechanical operations Functions as a recloser
Integrated design and attractive features Comes in different versions to cater to a multitude of customers

View Complete Details

Medium Voltage Vacuum Contactor




















ERL in technical collaboration with Joslyn Clark, U.S.A offer a range of rugged Medium Voltage Vacuum Contactors for heavy industrial applications. Unlike conventional devices, these vacuum contactors enclose the power contacts within a vacuum chamber.



APPLICATIONS



  • MV Motor Starter & Control

  • Transformer & Capacitor Switching

  • Pumping

  • Induction Heating

  • Soft Starters

  • Transfer Switches

  • Hazardous area equipment

  • Crane Control

  • Conveyors


Standard Features



































Front Accessible Modular design, low maintenance
Self - adjusting power contacts Fully phase insulated
Gangable design Wear indicator
1 Million electrical contact operations Reversible terminal design
Field changeable interrupters Field changeable control pack
Mechanically interlocked Impervious to harsh environments
Enclosed arc in vacuum chamber Compact size and light weight
Simplified Modular Construction

View Complete Details

Numerical Auto Reclose Relay




















The relay is suitable up to four shots. It consists of four cards viz.front fascia, power supply status input & output card and Micro controller card are housed in a compact 3N Non draw-out case.

Micro controller does the sequence control and timing function. The DIP Switches on the relay front fascia select different operating functions and time setting.There is a watchdog timer in the relay which continuously monitors the program, put off ^POWER ON^ LED indication if the watch dog timer elapses.

To start an auto re close cycle, the initiating contact from the protective relay must be closed without chatter for at least 12 milliseconds.

Inputs:
Two optically isolated inputs are provided. One is used to take the three phase protection operated contact inputs to initiate the auto rec lose relay.

The another input is used to block the re close functions if the external blocking input is initiated.

Reclose Timer:
The relay has four re-close timers. The relay selects the respective timer sequentially depending upon the number of re-close selection and the re-close initiation.

Reclaim Timer:
There is the common reclaim timer. It operates in series with the re-close timers. The over all reclaim time delay from the relay initiation to relay reset is therefore reclaim timer setting plus re-close time. For every initiation the reclaim time counting are resets automatically.

Lockout Function:
When the number of shots switch is in OFF mode the protection operated contact input initiation condition it will energize the lockout relay and lockout LED indication and it blocks the re-close function.

When the external blocking input is initiated, the re-close function is blocked and it energize external blocking LED, Lockout LED and Lockout relay.

As the relay allows the maximum of four re-close depending upon the number of shots selection, the number of shots is less than the number of initiation within the reclaim time it will energize the lockout relay and its LED indication


Standard Features



























Compact design Self-monitoring facility
Status indication LEDs Sealable front cover to prevent unauthorised access
Micro-controller based Automatic tripped breaker reclosure
Suitable for 3-phase reclosing 9 output contacts
4 status inputs Non-drawout case (140X104mm cutout)
Dip switches for parameter setting

View Complete Details

Remote Terminal Unit

  • Protect Feature Remote Terminal Unit (RTU)
  • Brand Name ERL
  • Port Bangalore Idia
  • Contact Load Low Power
  • Theory Solid State Relay
View Complete Details

Intelligent Solid Insulated Switchgear




















The Intelligent Solid Insulated Switchgear establishes a new benchmark for safety, reliability and compactness for the medium voltage switchgear. Solid Insulation Technology eliminates the need for dangerous polluting gases in switchgear applications at the same time makes the product more compact.

Application



  • Incoming and outgoing feeders

  • Bus risers and sectionalizers

  • Metering panels

  • Tie panels

  • Variety of switchgear panels in single and double bus bar variants


Standard Features




















Compact and space saving Standardized dimensions across all ratings
Environment friendly no Greenhouse gases Epoxy insulated active parts
Independently earthed compartments Each phase is independently metal-clad
Fire, explosion and water proof Totally maintenance free

View Complete Details

Test Plug

  • Protect Feature Relay Test Plug
  • Place of Origin India
  • Lead Time 8 weeks
  • Usage Protective

We are the main supplier of this product.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. Abhijit Dasgupta (ERL Marketing International)
  • No.1K – 08/02, PO Box 50669,Hamriyah Free Zone, Sharjah – UAE.
  • Share us via