Post Your Requirement Menu

Welcome User

Our Products

  1. Emergency Lights 1 Products / Services available
  2. Fiber Optic Cables 1 Products / Services available
  3. Thermocouple Cables 1 Products / Services available
  4. Electrical Cables & Wires 3 Products / Services available
  5. Wires 1 Products / Services available
  6. Telecommunication Equipment & System 1 Products / Services available
  7. Solar System Components 1 Products / Services available
  8. Conduit Pipe 1 Products / Services available
  9. Cables and Wire Accessories 1 Products / Services available
  10. Other Products 3 Products available

Solar System Components

Leading Manufacturer, Supplier & Retailer of Solar Cable.

Solar Cable

  • Sheath colour Black, Red
  • Operating temperature: -40 C / 90 C on the conductor
  • Overload temperature 120 C on the conductor
  • Expected lifetime >25 years
  • Rated voltage 1800 V DC
  • Max. temp in case of short circuit 250 C on the conductor (max. duration 5 seconds)
  • Min. bending radius 4 x outer diameter of the cable
  • Min. installation temperature -25 C
  • Max. laying stress during installation 50N/mm2

SINGLE CORE CABLES, FOR PHOTOVOLTAIC AND SOLAR SYSTEM USE, ELASTOMERIC COMPOUND INSULATED AND SHEATHED.


FLAME RETARDANT, HALOGENFREE AND LOW SMOKE FLEXIBLE CABLES FOR FIXED LAYING, LIFETIME TESTING 20.000 h/120C



1- Flexible tin plated copper class 5 EN 60228


2- LSOH Rubber compound



STANDARDS:

  • TV-Rheinland

  • 2 Pfg 1169/08.2007

  • IEC 60216-1

  • IEC 60216-2


APPROVALS:


MARKINGS:

ICC-SOLAR PV1-F size mm2 TV R 60030595 YEAR



APPLICATIONS:

  1. Cable suitable for the interconnection of the various elements of photovoltaic systems

  2. Suitable for fixed installation outside and inside without protection or inside pipes, ducts or similar closed systems.

  3. High resistance against ozone, U.V. rays, oils, moisture and weather inclemencies.

  4. Suitable for use at an ambient temperature up to 90 C (120 C overload) and tested according to: TUV- Rheinland 2 Pfg 1169/08.2007 Standard.

  5. The estimated lifetime of these cables is at least 25 years.

Size Max Ø of copper wires Insulation Thickness Sheath Thickness Outer diameter Max conductive resistance at 20° C Indicative cable weight
mm² mm mm mm mm ohms/km kg/km
1X4 0,31 0,7 0,8 5,5 5,09 62
1X6 0,31 0,7 0,9 6,3 3,39 85
1X10 0,41 0,7 1,0 7,5 1,95 135
1X16 0,41 0,7 1,0 8,5 1,24 200
View Complete Details

Tell Us What are you looking for? Will call you back

Contact Us

Misterlight Electrical Trading LLC

  • Misterlight Electrical Trading LLC (Misterlight Electrical Trading LLC)
  • P.O. Box: 55331, Deira, Dubai – U.A.E, Deira, United Arab Emirates
  • Share us via