Our Products
HVAC Contactor Supplier Dubai
Enclosure: Open
Power Poles: 2
Amp Rating: FLA 40 RES 50
Coil Voltage: 220VAC 50/60Hz
Resin Pack Split Type Air Conditioner Fan Motor DC Motor With Electric Motor Construction
YFK-07903004-TS07
220V-240V
50HZ
25W
Product details
Key Words Resin Pack Split Type Air Conditioner Fan Motor DC Motor
Application split INDOOR air conditioner use motor
Output 25-570w for Resin Pack Split Type Air Conditioner Fan Motor DC Motor
Protection Thermally Protected
Shaft plate with ni-coating
Protection Grade IP40
ZL-U03AB-EM Universal Air Conditioner PCB Board with AC Remote Control System
We bring high quality Air Conditioner PCB in Dubai that is procured from the most trusted and certified vendors of the market. These are fabricated using supreme quality raw material and advanced technologies in compliance with set standards. Owing to features, such as effective performance, compact design, rust resistance, durability and rigid construction, these are appropriately used in various industries. Moreover, our clients can avail these in various specifications at market leading prices.
The thermostat honeywell T6861 Super modern appearance design, suitable for office, hotel and residential building Horizontal and vertical model available for variant application Slim design, direct installation on 86 size box Stylish and elegant blue/green backlight with blue/ green colour ring 2-pipe/4-pipe integrated into one unit with easy configuration Big LCD display with English and icons Easy to install and set-up Time on/off function Selectable room temperature or setpoint display |
Specification:
The continuous or discontinuous spiral groove on inner surface of copper tube can increase contract area., change the flow type of refrigerant in the tube. The outer surface of copper tube can also be processed with corrugate spiral groove to expand range of use. It is suitable forheat exchangein home air conditioner or dry evaporator in central conditioner.
O.Din (mm) | BWT(mm) | Number of fins | FIN HEIGHT(mm) | Helix Angle | Weight(kg/m) |
(7.0) | 0.330 | 60 | 0.203 | 12 | 0.0781 |
5/16(7.94) | 0.305 | 60 | 0.203 | 18 | 0.0804 |
3/8(9.52) | 0.305 | 60 | 0.203 | 18 | 0.967 |
3/8(9.52) | 0.330 | 60 | 0.203 | 18 | 0.0989 |
3/8(9.52) | 0.356 | 60 | 0.203 | 18 | 0.1027 |
3/8(9.52) | 0.381 | 60 | 0.203 | 18 | 0.1205 |
3/8(9.52) | 0.406 | 60 | 0.203 | 18 | 0.1176 |
1/2(12.7) | 0.381 | 60 | 0.254 | 18 | 0.1622 |
1/2(12.7) | 0.406 | 60 | 0.254 | 18 | 0.1711 |
1/2(12.7) | 0.432 | 60 | 0.254 | 18 | 0.1792 |
1/2(12.7) | 0.456 | 60 | 0.254 | 18 | 0.1887 |
1/2(12.7) | 0.483 | 60 | 0.254 | 18 | 0.2064 |
5/8(15.88) | 0.498 | 75 | 0.305 | 23 | 0.2695 |
5/8(15.88) | 0.510 | 75 | 0.305 | 23 | 0.2695 |
5/8(15.88) | 0.510 | 75 | 0.305 | 25 | 0.3049 |
5/8(15.88) | 0.584 | 75 | 0.305 | 25 | 0.3240 |
5/8(15.88) | 0.635 | 60 | 0.305 | 27 | 0.3503 |
5/8(15.88) | 0.715 | 60 | 0.305 | 27 | 0.3726 |
The Copper Pair Coil with insulation coatcan be used in all plants for air conditioning and refrigeration and it is suitable for the use of refrigerating gas consistent with copper like R407 and R410A.
The in-line production control by defector and the continuous control of the external diameter and wall thickness guarantee the maximum safety of thecopper tubes. The tubes are supplied clean, internally decreased and capped.
Copper Pair Coil, used for connect indoor unit and outdoor unit of air conditioner.There are many different dimension as follows:
3m long
1/4 and 3/8 with flairs andpipe insulation;
3mlong
1/4 and 1/2 with flairs and pipe insulation;
5mlong
1/4 and 3/8 with flairs and pipe insulation;
5m long
1/4 and 1/2 with flairs and pipe insulation;
8mlong
1/4 and 3/8 with flairs and pipe insulation.
8mlong
1/4 and 1/2 with flairs and pipe insulation
15mlong
1/4 and 1/4 with flairs and pipe insulation.
15mlong
1/4 and 3/8 with flairs and pipe insulation
15mlong
1/4 and 1/4 with flairs and pipe insulation.
15mlong
1/4 and 1/2 with flairs and pipe insulation
15mlong
1/4 and 3/8 with flairs and pipe insulation.
15mlong
1/4 and 5/8 with flairs and pipe insulation
20mlong
1/4 and 1/4 with flairs and pipe insulation.
20mlong
1/4 and 3/8 with flairs and pipe insulation
20mlong
1/4 and 1/4 with flairs and pipe insulation.
20mlong
1/4 and 1/2 with flairs and pipe insulation
20mlong
1/4 and 3/8 with flairs and pipe insulation.
20mlong
1/4 and 5/8 with flairs and pipe insulation
Alloy: Copper Cu DHP 99, 90 min.
Internal surface smooth and mirror-like
Physical state: annealed
Excellent resistance to corrosion
Suitable for the new R407C and R410A gas
Air conditioning and refrigeration plants
Plants with heat pumps
Expanded polyethylene (PE) insulation
in-line extruded on the copper pipe
Produced according to the L 10/91 prescriptions
Fire resistance: self extinguishing Class 1
Marking: by laser at every meter
Extruded and closed cell synthetic rubber with external protection.
DENSITY(KG/M3):70-90
THERMAL CONDUCTIVITY-20040
W/(M/K)0.0310.0340.038
Working temperature from-50until +110(Flat surfaces +85)
Reaction to fire: self-extinguishing GB 8624B1 (OXYGEN INDEX>34%),
non-flammable
Vapour resistance:4500
The Refrigeration Copper Pipe Insulatedcan be used in all plants for air conditioning and refrigeration and it is suitable for the use of refrigerating gas consistent with copper like R407 and R410A.
The in-line production control by defectomat and the continuous control of the external diameter and wall thickness guarantee the maximum safety of the copper tubes. The tubes are supplied clean, internally degreased and capped.
Alloy: Copper Cu DHP 99, 90 min.
Internal surface smooth and mirror-like
Physical state: annealed
Excellent resistance to corrosion
Suitable for the new R407C and R410A gas
Air conditioning and refrigeration plants
Plants with heat pumps
Expanded polyethylene (PE) insulation
in-line extruded on the copper pipe
Produced according to the L 10/91 prescriptions
Colour: WHITE*
Insulation thickness: approx. 7 9 mm
Fire resistance: self extinguishing Class 1
Marking: by laser at every meter
Odourless and non-toxic CFC free
Thermal conductivity at 40C =