Post Buy Requirement
PS
Dubai, United Arab Emirates
Add Review

Other Products / Services #5764218

Ammeter Selector Switch

4 Position Ammeter Selector Switch
.
7 Position Voltmeter Selector Switch

View Complete Details

Panel Buzzer

Buzzer CBZ-10.Available in 12V, 24V, 110V and 220V.

Buzzer CBZ-20 .Available in 12V, 24V, 110V and 220V

Buzzer CBZ-30.Available in 12V, 24V, 110V and 220V

View Complete Details

Air Circuit Breaker

rame(A):1600N, 4000H1, 4000H2, 6300L In (A):630 6300

  • Ue(V):400/415, 690
  • Poles: 3P & 4P
  • Power demand meter function (A / A III / kW III / kVA III)
  • Type: Fixed type & Draw-out type
  • Certificates: CE, KEMA
  • Standards: I EC 60947-2
View Complete Details

Molded Case Circuit Breaker

Frame(A):1600N, 4000H1, 4000H2, 6300L In (A):630 6300
Basic Technical Data

  • Rated Insulation Voltage Ui: AC 800V (Frame 63AF: AC 690V)
  • Rated Impulse Withstand Voltage Uimp: 8KV (Frame 63AF: 6KV)
  • Rated Working Voltage Ue: AC 415V (Frame 63AF: AC 400)
  • Rated Working Frequency: 50Hz/60Hz
  • Utilization Category: A
  • Isolation Function: Applicable for all series
View Complete Details

Residual Current Protection Module

Standard:IEC 61008-1RCCB Type: AC, ASensitivity: 30, 100, 300mA
HDB6VR Residual current operated circuit breakers combine the following functions:

  • Protection for users against indirect contacts
  • Additional protection for users against direct contacts (30mA)
  • Protection for electrical installations against insulation faults (fire hazard, etc)
View Complete Details

AC Contactor

Standard: I EC 60947-4-1

Product Name Rated Current Main Current Coil Voltage Coil Frequency
HJX2 09 04 7

09:9A 12:12A95:95A

04:4NO+0NC 08:2NO+2NC B:24V X;440V 7:50/60Hz
View Complete Details

HLD11 Indicator Light

HLD 11 Series of indicator light provide:Pilot signal, anticipating signalsEmergency signals and other instructions incidents signal use
Technical Data

Rated Voltage(V) AC/DCt AC
Rated Current(MA)
Working Life (H)Brightness of the Iight(cd/m2) 3000240
Power Frequency withstand voltage)> 2500 VAC 1min

Before board protect degree

IP65 >>
View Complete Details

Panel Meter

HLD 11 Series of indicator light provide:Pilot signal, anticipating signalsEmergency signals and other instructions incidents signal use
Technical Data

Standard I EC 60051
Dielectric strength test Frequency 50/60Hz Voltage 2000V, Duration 1 m
Impact test Max acceleration 147m/s2
Response time 4s
Angular Deflection 90
temp -25 -+40
Humidity (25%-80%)RH
Evvironment No mildew, insects, salt mist, dew in the air, few sands and dusts are permitted.
Installation Shall be installed vertically
View Complete Details

Motor Circuit Breaker

Standard: I EC 60947-1, IEC 60947-2, I EC 60947-4-1

Product Name Frame Current Setting Current
HDP6 32 P16
32:32A P16:0.1-0. 16A 32:24-32AP means decimal point
View Complete Details

Modular Contactor

  • Automatic control on Equipment in buildings
  • Switch on or Switch off lighting or other equipments

Technical Information

Standard IEC 61095
Ambient Temperature -5C-40C
Rated Voltage Ue 230V AC
Rated Insulation Voltage Ui 500V AC
Operation Time >30000 times
Coil Volatge(Us) 220/23V AC
Type AC-7a AC-7B
Rated Current (le) 20A/25A/32A/40A/63A 7A/8.5A/12/A/15A/25A
Rated Power 4kW/5.4kW/6.5kW/8.4KW/13KW 1.2kW/1.5kW/1.9kW 2.4W/3.8kW
Operation Frequency 1200times/h 30time/h
Making & Breaking Capacity 1.5le 8le
View Complete Details

Electrical System Analyzer

  • Panel mounted electrical system analyzer (96 x 96 mm) which measures, calculates and displays the main electrical parameters in balanced and unbalanced three-phase systems
  • Slim line analyzer (only 50 mm deep)
  • Power demand meter function (A / A III / kW III / kVA III)
  • Current reading using external transformers ./5A (insulated inputs, according to type)
  • Option for measuring in Low and Medium Voltage systems
  • RS-485 communication (MODBUS RTU)
  • Compatible with the Power Studio / Scada system
  • 4 line backlit LED display
  • Allows selection of default page
  • Universal power supply available in "Plus" type & Medium Voltage Systems
  • RS-485 communication (MODBUS RTU)
View Complete Details

Power Factor Regulator Computer

The state-of-the-art regulators of the MAX Series have been designed to offer simple and efficient regulation features. The whole range of computer regulators is based on CIRCUTOR's FCP system (Fast Computerized Program), offering a set of unique performance features. Its main features are as follows:

  • Shows by display: cos , voltage, current, THD(I) and, besides, records in memory maximum values for voltage and current provides the "phase selection" function, that allows the user choosing the power line phase where the measuring current transformer (C.T.) has been placed in allows viewing in display the variation of cos , line current and THD(I), when manually connecting or disconnecting capacitor steps.
  • Indication by display or through relay output of following alarm conditions: Compensation failure,
  • Over-compensation, Over-voltage, Over-current, C.T. not connected or open, Line current below measurable value.
View Complete Details

Small, Compact Thermostat

KTO 011:Thermostat (normally closed); contact breaker for regulating heaters.
KTS 011:Thermostat (normally open); contact maker for regulating of filter fans and heat exchangers or for switching signal devised when temperature limit has been exceeded.

Features

  • Large setting range
  • Small size
  • Simple to mount
  • High switching performance
View Complete Details

Mechanical Hygrostat

The Electromechanica thermostat MFR 012 is designed to control enclosure heaters so that the dew point is raised when a critical relative humidity of 65% is exceeded. In this way condensation and corrosion is effectively prevented,

Features

  • Adjustable relative humidity
  • Change-over contact
  • High switching capacity
  • Easily accessible terminals
  • Clip fixing
View Complete Details

Roof Filter Fan

Roof filter fans and roof exhaust filters are used in enclosures from which warm air must be diverted due to increased heat development. The ready-to-connect and low-noise roof filter fan is used to expel warm air from within the enclosure. Alternatively, the roof exhaust filter provides passive ventilation. The RFP 018 series comes in two versions, one utilizes four small axial fans, improving reliability and maintaining continous operations even if one of the fans should fail, the second uses a larger single high capacity fan.

Features

  • Very low noise
  • Minimal mounting depth
  • High air volume
  • High reliability
  • Time-saving installation
View Complete Details

Semiconductor Heater

The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured.

Features

  • Dynamic heating up
  • Energy saving
  • Wide voltage range
  • Temperature limiting
  • Clip Fixing
View Complete Details

Filter Fan

Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating..
Features

  • Very low noise
  • Minimal depth in enclosure
  • Functional design
  • Time-saving installation
View Complete Details

Busbar Mounting Fuse Base Systems

3-pole, 60mm system, combination base for 5 and 10mm thick busbars and double-t-section latching mechanism when sliding onto busbar opened box terminal 1.5-25mm2

Features

  • 400V/63A
  • 50 kA short-circuit withstand capability
  • Power dissipation at nominal current-5.9W
  • Silicon free and halogen free
  • W x H x D - 36x 200x43
View Complete Details

Busbar Insulators

  • All Dimensions are in MM
  • Insert: Brass/Steel (Zinc Passivated)
  • Material : DMC (Dough Moulding Compound) (UL 94 V-0)
Height mm Insert PowermatCodeNo Rt Diamm Rb Diamm Hb Diamm Nominal Voltage( AC/DC)
25 M6 C625 (M6) 19 25 10 400/500
30 M6 C630 (M6) 25 30 10 600/750
30 M8 C830 (M8) 25 30 10 600/750
40 M8 C840 (M8) 33 40 15 1000/1200
40 M10 C1040(M10) 33 40 15 1000/1200
50 M10 C1050(M10) 40 50 20 1200/1500
50 M12 C1250(M12) 40 50 20 1200/1500
60 M10 C1060(M10) 42 50 20 1500/1800
60 M12 C1260(M12) 42 50 20 1500/1800
70 M10 C1070(M10) 41 50 25 2000/2400
70 M12 C1270(M12) 41 50 25 2000/2400
View Complete Details

Power Supply

  • Din rail mountable
  • Overload and short circuit protection
  • Industrial housing
  • Available in 5A, 10A, 20A with 12V and 24VDC
View Complete Details

Busbar Insulator

Properties Unit Value
Density g/cm 1.35
Tensile strength N/mm 180
Elongation at break % 3

Tensile modulus of elasticity

N/mm 11500
Impact strength charpy +23c KJ/m > 70
Impact strength charpy -40c KJ/m > 70

Other datas

Melting temperature C 214
Max operating temp permanent C 160
Tensile strength C 200
Elongation at break C 215

Tensile modulus of elasticity

% 1.9-2.4

Electrical data

Surface resistance Ohm 10
Di-electric strength Ohmcm 1015
Di-electric loss factor tan --- 0.024
Creepage factor --- 450

View Complete Details

Digital Measuring Instruments

  • Digital Ammeter
  • Digital Voltmeter
  • Digital Energy Meter
  • Digital Multi Function Meter
View Complete Details

Copper Brass Products

Cable Gland BW & CWAvailable Sizes20S, 20L TO 75S, 75L

Copper LugsAvailable Sizes2.5Sqmm x M5 to 630Sqmm x 21D

Copper BushAvailable sizes6x15, 6x20, 8x10, 8x15, 8x20

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Proliance Switchgear Solutions LLC (Proliance Switchgear Solutions LLC)
  • A Division of Al-Basma Group KSA Po.Box.84687 Dubai, United Arab Emirates
  • Share us via