Our Products
Bullet Poof Camps Characteristics:
Adopting container structure design, Riveting Bullet Proof steel plate in partition roof and wall, Providing emergency power and satellite emergency SOS device.
Be able to effectively protect personnel security of field construction staffs in the case of being attacked by stay bullet.
Our primary design requirement is to produce camps to deal with the ruggedness of its environment, having to withstand constant transportation in difficult off-road areas. All of our trailers are therefore designed to withstand this environment. Being designed around a rigid frame, which provides excellent support against torsional forces that these camps incur from being moved to off-road areas.
As with all our products we pride ourselves in providing excellent quality to our clients by paying attention to the detail of the fit-out and all details in the design stage. Our units are specifically designed for off-road use. Our windows are fixed, our doors are hinged in three places for stability and provided with wind break restrainers that do not break and all bolts are made of the hardwearing stainless steel and nylock type. All furniture is built-in and made from thicker than ordinary materials so that we can deliver a suitable product of high quality that will last.
The mixing tank has two connected agitating compartments. The mixed slurry in the first compartment will be mixed again in the second. The slurry in the second compartment will partly be sent downhole by a plunger pump, and partly back to high energy mixer to be mixed again.
The density of slurry is accurately controlled by a computer, which it is easy to operate; All job data are displayed in computer screen, and can be saved and downloaded. Real-time remote monitoring can be realized.
The system software is available both in English and Chinese, and measurement units can be changed from metric system to English system. The operators can perform simulation of mixing operation, thus training becomes convenient.
low pressure non-radioactive densitometer is used.
Fracturing instrument van is a major equipment of fracturing package, which can collect, show, and record the whole process of fracturing work. Several fracturing vans are controlled together. It can analyse and process fracturing working data. International standard couplings are used for data acquisition system with good interchangeability.
Operation control instrument and computer monitoring analysis are all centralized in van compartment with air-condition.It can be operated comfortably and safely.
Data collection and transmission control are all centralized so as to make several units work together.
Network control system is available.
GJC100-30(70-30)T trailer-mounted cementing units are fitted with 3ZB-450 triplex plunger pump and two deck engines to provide power for two cementing pumps respectively. The hydraulic system is powered by an independent engine installed in the front, thus operation will be more stable and reliable. The units are equipped with ACM-III automatic mixing system which will produce high quality slurry.
Max. working pressure, psi(MPa): 14147(97.5)
Max. working displacement, gpm(L/min): 792(3000)
LxWxH in.(mm): 480 x 105 x 154(12190x2650x3900)
Gross weight lb(kg): 61700(28000)
Model of chassis: THT9360TD semi-trailer
Deck engine: DDC6064-MK33x2(CAT engines will be used)
Power, hp(kW): 450(336)@2100r/min
Front engine: DDC6044-TK33
Power hp(kW): 275(205)@2100r/min
Hydromechanical transmission: ALLISON HD4700 OFS
Plunger pump assy: 3ZB-450x2
Max. input power of each pump hp(kW):600(447)
Plunger dia.: 4.5"(0114.3mm)+3"((D76.2mm) or 3.5"((D88.9mm)+4"(4)101.6mm)
Mixing system: ACM-III automatic mixing system or Injection type mixing system
The Drill collar slips are fallen into three models, that is, DSC-S, DSC-R, and DSC-L. The models can be used to handle drill collars with outer diameters from 3" OD to 14" OD
Model |
Unit |
TC-135 |
TC-170 |
TC-225 |
TC-315 |
TC-450 |
TC-585 |
Max. Hook Load |
kN |
1,350 |
1,700 |
2,250 |
3,150 |
4,500 |
5,850 |
lbs |
300,000 |
370,000 |
500,000 |
700,000 |
1,000,000 |
1,300,000 |
|
Wire line O.D. |
mm |
29 |
29 |
32 |
35 |
38 |
42 |
inch |
1 1/8 |
1 1/8 |
1 1/4 |
1 1/8 |
1 1/2 |
1 5/8 |
|
Sheave O.D. |
mm |
1,016 |
1,016 |
1,120 |
1,270 |
1524 |
1,524 |
inch |
40 |
40 |
44 |
50 |
60 |
60 |
|
Sheave No. |
No. |
5 |
6 |
6 |
7 |
6 |
8 |
Overall Dimensions |
L/ mm |
2,320 |
2,668 |
2,668 |
3,192 |
3410 |
3,625 |
inch |
91 21/62 |
105 3/76 |
105 3/76 |
125 2/3 |
134 1/4 |
142 43/60 |
|
W/mm |
2,076 |
2,460 |
2,710 |
2,783 |
2753 |
2,832 |
|
inch |
81 52/71 |
96 17/20 |
106 9/13 |
109 55/97 |
108 22/57 |
111 1/2 |
|
H/mm |
3 |
1,856 |
2,469 |
2,350 |
2420 |
2,580 |
|
inch |
70 1/2 |
70 1/2 |
70 1/2 |
70 1/2 |
70 1/2 |
70 1/2 |
|
Approx. Weight |
Kg |
2,670 |
4,540 |
6,500 |
8,500 |
11100 |
12,100 |
lbs |
5,933 |
10,089 |
14,444 |
18,889 |
24,667 |
26,889 |
The patented hose assemblies, specially designed for BOP control pipes, can normally work for five minutes when it is under the fire at a 1093? temperature, the pipe has no defects affecting the use. It can work normally for 20 minutes when it is under the fire at a 750? temperature, the pipe has no defects affecting the use. This product has passed the certification of ISO9000 Quality System.
Casing Slips can accommodate casing from 6 5/8" to 30" OD The multi-segment casing slips conform to API Spec 8A/8C, API monogram permitted to be stamped.
Trucking Mounted / Trailer Mounted / Skid Mounted
Coiled tubing operation technology now is popular in the oil & gas industry, with operation depth up to 9000m, and gradually become a trend of workover technology. At present, 12.7114.3 mm coil tubings are available.
The preliminary coiled tubing units are used for fluid transmission in well washing, base medium acidizing and nitrogen lift. Now the coiled tubing technologies are extended to drilling, workover, logging, perforation and stimulations. The trend will be for fracturing, shallow well drilling, etc.
LGC230 coiled tubing units, suitable for 1"2" tubing, are used for well flushing, sand flushing, wax removing, acidizing, nitrogen injecting and fishing operations. The unit consists of main coil tubing unit, auxiliary unit and downhole tools.
Faster operation, higher efficiency, save 50% of workover time. Quicker installation and movement.
Wider operation range. Besides conventional service, can be used for special downhole operations.
Operation controls are centralized, highly automatic.
Safe and reliable operation. The killing opration which can cause damage to oil reservoir will not be needed any more.
Skid Mounted Camps classified by their functions include: Accommodation camps, Project manager camp, Supervisor camps, Meeting rooms, Office rooms, Kitchens, Dining rooms, Freezer and Cold Storage house, Laundries, Shower rooms, Toilets, Gyms, Material and Tool houses, MCC house, Wellsite Duty rooms, Mud Lab rooms, Dog house and other functional camps used in living camps area and rig site working area.