Post Buy Requirement
AL
United Arab Emirates
Add Review

Electrical Circuit Breaker #1199694

Metal Clad Switchgear

  • Air insulated Medium Voltage Metal clad switchgear, as per IEC 62271-200.  
  • Rated Voltage 12kV
  • Main Bus current Ratings (630/1250/3150)A
  • Functional units Incoming Feeder, outgoing Feeder, Bus Riser, Bus Section, Bus VT (Bus Earthing).
  • Short circuit withstand current up to 31.5KA.  
  • Short circuit duration tsc=3 sec  
  • Frequency 50 Hz
  • Power frequency withstand voltage( for 1 min ) 38 kV (rms)
  • Lightning impulse withstand voltage (1.2/50 μs)
  • Internal Arc Classification AFLR (31.5KA/1s)
  • Loss of Service continuity LSC2B-PM
12 KV metal clad switchgear , type alfa12

alfanaraLFa12 is an air-insulated Medium Voltage metal clad switchgear. It is designed, manufactured and type-tested in accordance with the latest IEC standards and GCC region specifications.
alfa12 is commonly used in control and protection of medium voltage power equipment and circuits in industrial, commercial and utility installations involving medium voltage distribution feeders.

View Complete Details

Air Insulated Switchgear

  • Frequency 50 Hz
  • Rated Voltage 12kV
  • Main Bus current Ratings (630/1250/3150)A
  • Functional units Incoming Feeder, outgoing Feeder, Bus Riser, Bus Section, Bus VT (Bus Earthing).
  • Short circuit withstand current up to 31.5KA.  
  • Short circuit duration tsc=3 sec  
  • Power frequency withstand voltage( for 1 min ) 38 kV (rms)
  • Lightning impulse withstand voltage (1.2/50 μs)
  • Internal Arc Classification AFLR (31.5KA/1s)
  • Loss of Service continuity LSC2B-PM

alfanaraLFa12 is an air-insulated Medium Voltage metal clad switchgear. It is designed, manufactured and type-tested in accordance with the latest IEC standards and GCC region specifications.
alfa12 is commonly used in control and protection of medium voltage power equipment and circuits in industrial, commercial and utility installations involving medium voltage distribution feeders.

  • Air insulated Medium Voltage Metal clad switchgear, as per IEC 62271-200.
View Complete Details

Metal Enclosed Switchgear

  • Short circuit withstand current 21 KA
  • Short circuit duration 1 sec
  • Power frequency Withstand voltage (1 min) 38/50 KV
  • Lightning Impulse withstand voltage Up 95/110/125 KV
  • Functional units Incoming /outgoing units , Transformer protection unit

lfanarME6 units are Modular Extensible Air insulated metal enclosed switchgear, designed for supplying sustainable energy, protecting electrical equipment in secondary distribution networks.ME6 is realized with standardized typical units. During the design stage of the units we took into consideration the functionality, the simplicity of operation and locking devices and a long period of service with limited maintenance.

  • Technical Specifications:
    • Modular Extensible Air insulated Ring Main Units
    • Rated voltage Ur = 17.5/24 KV
    • Rated thermal current (at 40 C) Ir= 630 A
    • Loss of service continuity category (LSC) LSC2A
    • Internal arc classified sides AFLR
    • Degree of protection IP41