Post Your Requirement Menu

Welcome User

Our Products

  1. Brackets 1 Products / Services available
  2. Fuses, Circuit Breakers & Components 1 Products / Services available
  3. Electrical Conductor 1 Products / Services available
  4. Air Conditioners 2 Products / Services available
  5. Laces, Interlinings & Other Accessories 1 Products / Services available
  6. Relays 1 Products / Services available
  7. Coupling 1 Products / Services available
  8. Electric Motor Parts 1 Products / Services available
  9. Earthing Equipment 1 Products / Services available
  10. Switchboards 1 Products / Services available
  11. Cabinets & Enclosures 3 Products / Services available
  12. Sockets 1 Products / Services available
  13. Pipe Tees 1 Products / Services available
  14. Level Switches 1 Products / Services available
  15. Adaptors, Plugs and Sockets 1 Products / Services available
  16. Potentiometer 1 Products / Services available
  17. Insulated Cable 1 Products / Services available
  18. Push Button Switches 1 Products / Services available
  19. Cables and Wire Accessories 3 Products / Services available
  20. Heat Exchangers 1 Products / Services available
  21. Wire Making Machines 1 Products / Services available
  22. Storage Drums, Tanks & Containers 1 Products / Services available
  23. Cable Tray 1 Products / Services available
  24. Storage Tanks 1 Products / Services available
  25. Hardware Fittings and Accessories 1 Products / Services available
  26. Safety Equipments 1 Products / Services available
  27. Fasteners 1 Products / Services available
  28. Electrical Cables & Wires 1 Products / Services available
  29. Power Cables 1 Products / Services available
  30. Pipe Clamps 1 Products / Services available
  31. Flexible Conduits 1 Products / Services available
  32. Kitchen Rack 1 Products / Services available
  33. Decorative Lights, Lamps & Lamp Shades 1 Products / Services available
  34. Power Contactors 1 Products / Services available
  35. Bushings 3 Products / Services available
  36. Voltmeter 1 Products / Services available
  37. Nuts Bolts and Fasteners 1 Products / Services available
  38. Lighting Pole 1 Products / Services available
  39. Buttons 1 Products / Services available
  40. Light Fitting 3 Products / Services available
  41. Electrical Switches 1 Products / Services available
  42. Lamps 1 Products / Services available
  43. Distribution Box 1 Products / Services available
  44. Torchlight 1 Products / Services available
  45. Cupboard 1 Products / Services available
  46. Street, Flood & Commercial Lights 2 Products / Services available
  47. Transformers 1 Products / Services available
  48. Plastic Pipe Fittings 1 Products / Services available
  49. Home Appliance Repair 1 Products / Services available
  50. Reading Lights 1 Products / Services available
  51. Modular Switches 1 Products / Services available
  52. Clamps 4 Products / Services available
  53. Conduit Pipe 1 Products / Services available
  54. Other Products 18 Products available

Other Products / Services

We are leaders in the market for providing best range of Explosion-proof Caution Spotlight Fittings, STRONG WORKING LIGHTS, Air Rod Bases & Saddles, AIR RODS and air termination system

Explosion-proof Caution Spotlight Fittings

Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Class 1, Zone 1 and Zone 2 Class 1, Division 1, Groups A, B, C, D Ultra-bright LED lamp, low power consumption and long service life. Lamp colour: red, blue, yellow, green. Enclosure in copper-free aluminium, powder coated surface, yellow (RAL1021).

View Complete Details

STRONG WORKING LIGHTS

Strong Working Lights Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Class I, Zone 1 and Zone 2 Class I, Division 2, Groups A, B, C, D Safe and reliable: the product has good explosion-proof performance and can safely and reliably work in various hazardous areas. Efficient and energy-saving: special gas discharging lamp; high luminous efficiency, luminous flux is 5 times of that of a halogen lamp with the same power, illumination is 3 times that of a 100W halogen bulb, service life is 5-10 times of that of a normal halogen lamp, and for the same brightness the power consumption is 15% of that of a normal halogen lamp, good anti-shock effect, small heating value, safer and more reliable. Waterproof and damage-proof: the light is totally sealed and can work normally in wet environments, a special alloy enclosure ensures the light can resist strong shock and impact Economic and environmental friendly: the memory-free battery can be charged and laid aside for a year, the reserve of electricity is not less than 80% full after two years, it is not less than 50% low-voltage discharging protection circuit is set; reliably protects the battery and prolongs the service life Convenient and durable: a unique lamp cap, the lighting angle can be adjusted at random and there are wheels at the bottom to easily to move the lamp Other: normally a floodlight is provided; however a spotlight is available on request  

View Complete Details

Air Rod Bases & Saddles

Air Rod Bases & Saddles The role of an air termination system is to capture the lightning discharge current and dissipate it harmlessly to earth via the down conductor and earth termination system. Therefore it is important to use a correctly designed air termination system. IEC/BS EN 62305-3 advocates the following, in any combination, for the design of the air termination: Air rods (or finials) whether they are free standing masts or linked with conductors to form a mesh on the roof Catenary (or suspended) conductors, whether they are supported by free standing masts or linked with conductors to form a mesh on the roof Meshed conductor network that may lie in direct contact with the roof or be suspended above it (in the event that it is of paramount importance that the roof is not exposed to a direct lightning discharge) The standard makes it quite clear that all types of air termination systems that are used shall meet the positioning requirements laid down in the body of the standard. It highlights that the air termination components should be installed on corners, exposed points and edges of the structure. The three basic methods recommended for determining the position of the air termination systems are: The rolling sphere method The protective angle method The mesh method

View Complete Details

AIR RODS

The role of an air termination system is to capture the lightning discharge current and dissipate it harmlessly to earth via the down conductor and earth termination system. Therefore it is important to use a correctly designed air termination system. IEC/BS EN 62305-3 advocates the following, in any combination, for the design of the air termination: Air rods (or finials) whether they are free standing masts or linked with conductors to form a mesh on the roof Catenary (or suspended) conductors, whether they are supported by free standing masts or linked with conductors to form a mesh on the roof Meshed conductor network that may lie in direct contact with the roof or be suspended above it (in the event that it is of paramount importance that the roof is not exposed to a direct lightning discharge) The standard makes it quite clear that all types of air termination systems that are used shall meet the positioning requirements laid down in the body of the standard. It highlights that the air termination components should be installed on corners, exposed points and edges of the structure. The three basic methods recommended for determining the position of the air termination systems are: The rolling sphere method The protective angle method The mesh method

View Complete Details

air termination system

The role of an air termination system is to capture the lightning discharge current and dissipate it harmlessly to earth via the down conductor and earth termination system. Therefore it is important to use a correctly designed air termination system. IEC/BS EN 62305-3 advocates the following, in any combination, for the design of the air termination: Air rods (or finials) whether they are free standing masts or linked with conductors to form a mesh on the roof Catenary (or suspended) conductors, whether they are supported by free standing masts or linked with conductors to form a mesh on the roof Meshed conductor network that may lie in direct contact with the roof or be suspended above it (in the event that it is of paramount importance that the roof is not exposed to a direct lightning discharge) The standard makes it quite clear that all types of air termination systems that are used shall meet the positioning requirements laid down in the body of the standard. It highlights that the air termination components should be installed on corners, exposed points and edges of the structure. The three basic methods recommended for determining the position of the air termination systems are: The rolling sphere method The protective angle method The mesh method

View Complete Details

ANTI-VANDAL CONDUCTOR GUARD

By far the largest and most important component of any structural lightning protection or earthing system is the actual conductor. Selection of the correct conductor type for the installation is highly important, and is likely to be the initial consideration of a lightning protection or earthing system designer. A comprehensive range of copper and aluminium conductors is available in each of the main world standard formats, i.e. flat tape, solid circular and stranded. Additionally each format is available in a variety of conductor sizes, to meet differing lightning protection and earthing requirements. Specification will depend on whether the application is for an above ground structural lightning protection system, or a below ground earthing installation.Conductors for structural lightning protection systems Lightning protection conductors are available in copper and aluminium, and are supplied bare or with PVC coating (see below). For most installations, copper is specified due to its high conductivity and anti-corrosive properties. The following sizes are suitable for the majority of above ground lightning protection systems: Flat tape conductor 25 x 3 mm bare tape, or 25 x 3mm PVC covered tape Solid circular conductor 8 mm diameter bare or PVC covered solid circular conductor Stranded conductor 70 mm² bare or PVC covered stranded conductor

View Complete Details

BIMETALLIC CABLE CONDUCTOR

Bimetallic Cable  Conductor By far the largest and most important component of any structural lightning protection or earthing system is the actual conductor. Selection of the correct conductor type for the installation is highly important, and is likely to be the initial consideration of a lightning protection or earthing system designer. A comprehensive range of copper and aluminium conductors is available in each of the main world standard formats, i.e. flat tape, solid circular and stranded. Additionally each format is available in a variety of conductor sizes, to meet differing lightning protection and earthing requirements. Specification will depend on whether the application is for an above ground structural lightning protection system, or a below ground earthing installation.Conductors for structural lightning protection systems Lightning protection conductors are available in copper and aluminium, and are supplied bare or with PVC coating (see below). For most installations, copper is specified due to its high conductivity and anti-corrosive properties. The following sizes are suitable for the majority of above ground lightning protection systems: Flat tape conductor 25 x 3 mm bare tape, or 25 x 3mm PVC covered tape Solid circular conductor 8 mm diameter bare or PVC covered solid circular conductor Stranded conductor 70 mm² bare or PVC covered stranded conductor

View Complete Details

HARD DRAWN BAR

Hard Drawn Bar By far the largest and most important component of any structural lightning protection or earthing system is the actual conductor. Selection of the correct conductor type for the installation is highly important, and is likely to be the initial consideration of a lightning protection or earthing system designer. A comprehensive range of copper and aluminium conductors is available in each of the main world standard formats, i.e. flat tape, solid circular and stranded. Additionally each format is available in a variety of conductor sizes, to meet differing lightning protection and earthing requirements. Specification will depend on whether the application is for an above ground structural lightning protection system, or a below ground earthing installation.Conductors for structural lightning protection systems Lightning protection conductors are available in copper and aluminium, and are supplied bare or with PVC coating (see below). For most installations, copper is specified due to its high conductivity and anti-corrosive properties. The following sizes are suitable for the majority of above ground lightning protection systems: Flat tape conductor 25 x 3 mm bare tape, or 25 x 3mm PVC covered tape Solid circular conductor 8 mm diameter bare or PVC covered solid circular conductor Stranded conductor 70 mm² bare or PVC covered stranded conductor

View Complete Details

LEAD COVERED CONDUCTOR

Lead Covered Conductor By far the largest and most important component of any structural lightning protection or earthing system is the actual conductor. Selection of the correct conductor type for the installation is highly important, and is likely to be the initial consideration of a lightning protection or earthing system designer. A comprehensive range of copper and aluminium conductors is available in each of the main world standard formats, i.e. flat tape, solid circular and stranded. Additionally each format is available in a variety of conductor sizes, to meet differing lightning protection and earthing requirements. Specification will depend on whether the application is for an above ground structural lightning protection system, or a below ground earthing installation.Conductors for structural lightning protection systems Lightning protection conductors are available in copper and aluminium, and are supplied bare or with PVC coating (see below). For most installations, copper is specified due to its high conductivity and anti-corrosive properties. The following sizes are suitable for the majority of above ground lightning protection systems: Flat tape conductor 25 x 3 mm bare tape, or 25 x 3mm PVC covered tape Solid circular conductor 8 mm diameter bare or PVC covered solid circular conductor Stranded conductor 70 mm² bare or PVC covered stranded conductor

View Complete Details

PVC COVERED CONDUCTOR

PVC Covered Conductor By far the largest and most important component of any structural lightning protection or earthing system is the actual conductor. Selection of the correct conductor type for the installation is highly important, and is likely to be the initial consideration of a lightning protection or earthing system designer. A comprehensive range of copper and aluminium conductors is available in each of the main world standard formats, i.e. flat tape, solid circular and stranded. Additionally each format is available in a variety of conductor sizes, to meet differing lightning protection and earthing requirements. Specification will depend on whether the application is for an above ground structural lightning protection system, or a below ground earthing installation.Conductors for structural lightning protection systems Lightning protection conductors are available in copper and aluminium, and are supplied bare or with PVC coating (see below). For most installations, copper is specified due to its high conductivity and anti-corrosive properties. The following sizes are suitable for the majority of above ground lightning protection systems: Flat tape conductor 25 x 3 mm bare tape, or 25 x 3mm PVC covered tape Solid circular conductor 8 mm diameter bare or PVC covered solid circular conductor Stranded conductor 70 mm² bare or PVC covered stranded conductor

View Complete Details

TINNED CONDUCTOR

Tinned Conductor By far the largest and most important component of any structural lightning protection or earthing system is the actual conductor. Selection of the correct conductor type for the installation is highly important, and is likely to be the initial consideration of a lightning protection or earthing system designer. A comprehensive range of copper and aluminium conductors is available in each of the main world standard formats, i.e. flat tape, solid circular and stranded. Additionally each format is available in a variety of conductor sizes, to meet differing lightning protection and earthing requirements. Specification will depend on whether the application is for an above ground structural lightning protection system, or a below ground earthing installation.Conductors for structural lightning protection systems Lightning protection conductors are available in copper and aluminium, and are supplied bare or with PVC coating (see below). For most installations, copper is specified due to its high conductivity and anti-corrosive properties. The following sizes are suitable for the majority of above ground lightning protection systems: Flat tape conductor 25 x 3 mm bare tape, or 25 x 3mm PVC covered tape Solid circular conductor 8 mm diameter bare or PVC covered solid circular conductor Stranded conductor 70 mm² bare or PVC covered stranded conductor

View Complete Details

Overhead Line Conductors

Overhead Line Conductors Aswathy has capability to provide complete range of overhead line conductors in Aluminium, Aluminium Alloy and Copper. The standard range includes sizes up to 1000mm² as per BS, IEC, DIN, ASTM,  or any other international standard and customer’s specifications for all voltage applications. We can also provide conductors with XLPE or PVC covering. The standard types of conductors in our present manufacturing range are as follows: AAC All Aluminium Conductors AAAC All Aluminium Alloy Conductor ACSR Aluminium Conductor Steel Reinforced HDBC Hard Drawn Bare Copper conductor SDBC Soft Drawn Bare copper Conductor AAC + XLPE All Aluminium Conductor with XLPE insulation AAC + PVC All Aluminium conductors with PVE insulation

View Complete Details

Perforated Profiles

Perforated Profiles We offer a range of standard perforated profiles suitable for welding during construction. These can then be treated and coated together with the main structure..

View Complete Details

Circuit Breaker Modules

Circuit Breaker Modules Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Class I, Zone 1 and Zone 2 Class I, Division 2, Groups A, B, C, D Product of flame-proof structure; the cavity is of engineering plastic embedded with high strength metal frame structure; with strong corrosion-proof capacity and reliable performance. Built-in Schneider iC65 series MCB, special operation mechanism internally designed, reliable overall operation.  

View Complete Details

Weatherproof Control Unit Systems

Control Unit Systems Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Class I, Zone 1 and Zone 2 Class l, Division 1, Groups A, B, C, D Copper-free aluminium, powder coated surface, GRP Enclosures Individual unit can be combined into larger units.   Weatherproof  Control Unit Systems Enclosure is made of pressed engineering plastics with an attractive appearance Anti-aging, deformation-free, impact resistant and corrosion resistant etc. The product has strong acid and strong alkali resistance, anti-salt, anti-seawater and chloride corrosion resistance. Built-in components: button, indicator, etc. The brand of inner components shall be recommended by Manufacturer. Note: no more than 3 units can be installed, such as, one button, two buttons, three buttons, one button and one light, one button and one switch, two buttons and one light, etc. If more than 3 units are required a control station should be used.

View Complete Details

Motor Switches

Motor Switches Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Class I, Zone 1 and Zone 2 Class I, Division 1, Groups A, B, C, D Classified as IIC according to gas atmosphere. Copper-free aluminium enclosure, powder coated surface. Built-in MCB (miniature circuit breaker), MCCB (moulded case circuit breaker). Earth leakage protection device is optional.  

View Complete Details

Cathodic Protection System

CATHODIC PROTECTION SYSTEM   Protects infrastructure asset such as an above ground storage tank, buried pipeline, reinforcing steel in concrete structure, heat exchanger, marine pile, sheet pile wall or other metallic structure from corrosion.   Site Survey, Investigation, Engineering Design Anodes (Impressed Current, Sacrificial) Zinc, Aluminium and Magnesium Transformers & Rectifiers Control Boxes – Bonding Station & Test Stations Remote Monitoring Systems Special Cables for Cathodic Protection Insulating Joints. Anode JB, Cathode JB Cathodic Protection Rectifier Electrical Heat Tracing Systems & Accessories

View Complete Details

Cable Glands Armored Compound Barrier

Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Class I, Zone 1 and Zone 2 Class I, Division 1, Groups A, B, C, D Ex d, Ex e structure; available in stainless steel, nickel plated brass or galvanized carbon steel. With sealing ring and sealing compound; suitable for armored cable.

View Complete Details

Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. Aneeshkumar M. Pillai
  • Executive Suite Z 2 – 15, SAIF Zone, Post Box 121477 SHARJAH, UNITED ARAB EMIRATES, Sharjha, United Arab Emirates