We offer a complete product range of Led Panels, Wall Washer STREAM, Miniature Circuit Breakers, HRC Fuse Links and Bases and NT Isolating Switches

Led Panels

  • Power 36W/40W
  • Rated voltage 230VAC
  • Power supply control gear, DC device - driver
  • LED type SMD
  • Luminous flux 36W – 2400lm 40w - 3200lm 40W – 3200lm
  • Colour temperature 4000-4300К/6000-6400k(model only 45w-595x595mm)
  • Protection against dust and moisture IP40
  • Dimensions 36W – 595x595mm 40w - 595x595mm 40W – 1195x295mm

Housing: aesthetic aluminum frame, no change of color over time  - Diffuser: even distribution of lights, without formation of lighter or darker spots  - Installation: built-in / pendant kit available  - Long life: 15000 hours   Application areas: - Residential buildings  - Commercial buildings  - Administrative buildings  - Banks  - Hospitals  - Schools   Benefits: - Completely replace traditional fluorescent lighting  - Safety, low voltage operation  - Installation options: suspended ceilings, artificial walls, pendant mounting  - Emit a very pleasant and even light with very low glare factor due to the diffusion lens  - Low power consumption  - Repeated switch-on/off does not affect the lifespan of the LED panel  - Instant light with maximum luminous flux  - Environmentally friendly - do not emit mercury and lead (RoHS Directive)  - No ultraviolet and infrared rays  - Resistant to shock and vibration

View Complete Details

Wall Washer STREAM

  • Color Temperature 5500K
  • Power 9W/18W/36W
  • Rated voltage 85V – 265V
  • Power supply low-voltage, direct-current device - driver
  • LED type High power
  • Luminous flux STREAM 9W – 720lm STREAM 18W – 1440lm STREAM 36W – 2880lm
  • Protection against dust and moisture IP65

Housing: aluminum body - Colour of the housing: grey - Resistance: -40°C ÷ +65°C - Long life: 30000 hours   Application area: - Sports halls - Commercial areas - Warehouses - Production facilities - Squares - Fleets - Parking lots   Benefits: - Efficient replacement of traditional halogen and metal-halide floodlights - Wide distribution of even and stable light - Economic- low power consumption - Repeated switch on/off does not effect the fixture lifespan - Instant light at maximum luminous flux - Environmentally friendly - no mercury and lead - No ultraviolet and infrared rays - Resistant to shock and vibration stable body - Voltage supply fluctuations do not affect the normal operation of the floodlights

View Complete Details

Miniature Circuit Breakers

  • Rated operating voltage 230/400V; 50/60Hz
  • Rated current 2-63А
  • Breaking capacity: 4500 А
  • Poles 1, 2, 3
  • Tripping curve C С - the maximum current release breaks between 5 and 10 In; used to protect main power supply ca

Electrical wear resistance (number of cycles ):≥4000 - Mechanical wear resistance (number of cycles):≥20000 - Limitation class: 3 - IP code: IP>20 - Ambient temperature: -5 до +40°С±2°С   Mounting : Vertical on a DIN rail    Standards : EN60898-1

View Complete Details

HRC Fuse Links and Bases

  • Rated voltage 500V
  • Rated short circuit current from 16А to 630А
  • Dimensions NT00 / NT0 / NT1 / NT2 / NT3

Direct mounting to the load - IP code: IP 00 - Porcelain/dielectric alloy - Ambient temperature: - 5° to +55   Mounting: - Via bolts to the mounting plate   Standards: EN 60269-2 EN 60269-1 IEC269-2  

View Complete Details

NT Isolating Switches

  • Rated voltage 500V
  • Rated short circuit current acc to the mounted fuse links - Size of the fuse links: NT00 / NT1 / NT2 / NT3
  • Number of poles 3

 Vertical / Horizontal options - Surge voltage wear resistance: 8 kV - Mechanical wear resistance: 3000 cycles - IP code: IP 40 - Resistant to UV rays plastic - Ambient temperature: -5° до +55°С      Mounting: - Via bolts to the mounting plate - Directly to the power supply rails   Standards: EN 60947-1 EN 60947-3    

View Complete Details

Cylindrical Fuse Links

  • Rated voltage 500V
  • Rated short circuit current from 1А to 63А
  • Ambient temperature -5° до +55°С
  • Dimensions 10х38 / 14х51
  • Class gG

Standard:  EN 60269-2;  IEC269-2  EN 60269-1  

View Complete Details

switch disconnectors

  • Rated voltage: 500V
  • Insulation voltage: >2500V
  • Rated short circuit current 100 кА

Direct mounting to the load - Two insulated points to the load - Number of poles: 1P/1P+N/2P/3P/3P + N - IP code: IP 44 - Section of the power supply conductors: up to 35mm2 - Ambient temperature: -5° up to +55°С   Mounting: - DIN rail   Standards:  - EN 60269-2 - IEC269-2

View Complete Details

Manual Change-Over Switch

  • Rated operating voltage not higher than 660V; 50/60Hz
  • Rated current 160-800А
  • Insulation voltage ≥1000V
  • Number of poles 3,4
  • IP code IP>20

Mounting :  to a flat surface using bolts   Advantages: - Resistant to high voltages - Option for moving the handle on the front panel of the board - High mechanical endurance and wear resistance - Not affected by the frequency variations - Reliable and secure control - Long life Functions: - For mounting in main electrical boards for breaking of the circuits - Manual switching between two power supplies - Switching ON of generators - Used as main switch Applications: - Industry - Administrative and public buildings - Building construction Standards:  ЕN 60947- 1 EN 60947-3

View Complete Details

Automatic Switch EQ1

  • Rated Current 100-630А
  • Rated operating voltage 690V; 50/60Hz
  • IP code IP21
  • Surge voltage wear resistance ≥6 000V

Mounting : vertically on a flat surface using bolts   Advantages: - Selection between device with integrated and separated controller - Option for setting the change-over time between the two sources – min 3s - Option for automatic switch-over to the main power supply source after restoring its parameters - High reliability, safety and long life Functions: - Provide continuous power supply and two electrical sources automatic switch in case of failure or deviation from the set parameters - Control the status of the circuit parameters:          presence of the three phases         limits of the phase voltage         overload         short circuit at the output - Switching to dual power change-over at power supply phase lack - Breaking of electrical circuits and control of powerful consumers - Main breaker in housing or industrial distributing installations supplied with a generator or with a second power supply source   Applications: - Administrative and public buildings-hospitals, military sites, control rooms - Industry-productions requiring continuity of the process - Generators            Standards:  EN 60947-1   EN 60947-2     EN 60947-6-1

View Complete Details

Under Voltage Release

The device switches off and/or does not allow the switching on of the breaker to which it is mounted at power breakdown or voltage decrease under certain limits   TECHNICAL DATA:   • operating voltage: 230/400V 50Hz • electromagnetic coil 6VA for breakers up to 400A • electromagnetic coil 10VA for breakers 630-800A • available joining conductors • switches off at voltage decrease under 75% of the operating   MOUNTING:   Mounted in a special jack after cover dismounting Note: The breakers are offered with mounted accessory   CONNECTING:   Connected with the operative system through the provided conductors

View Complete Details

Terminal plates for MCCB

Straight copper electro-tinned extensions enabling cable connection outside the switch terminals and providing excellent contact with the switch terminal base. Terminal extensions with different cross section are available depending on the switch rated power.   MOUNTING: Extensions are directly bolt mounted to the switch terminal base

View Complete Details

Remote control (manual)

The device switches off/on the breaker to which manual operative rotary mechanism is mounted • two operating positions of the executive mechanism fixed at 90°C   Mounting:   The base is mounted with bolts right on the cover (scheme 1 mounting), and the handle is mounted at the door of the distribution box, using an extension axis it is joined to the base

View Complete Details

residual current devices

  • Rated current 10-100 А
  • Rated operating voltage 230/400V; 50/60Hz
  • Rated residual current 30/100/300/500 mA
  • Number of poles 2/4
  • Surge voltage wear resistance ≥2 000V
  • Short circuit current wear resistance: 6000А
  • IP code IP>20
  • Ambient temperature -10°÷45ºС
  • Maximum altitude up to 2000m

Mounting : vertical on a DIN rail Standards:  EN 61008-1  EN 61008-2  EN 60947-1  

View Complete Details

Contactors LP1

Technical characteristics: - Rated current: from 9A up to 225А - Rated operating voltage of the controlling coil: 12V DC to 230V DC - Rated operating voltage of the power circuit: up to 690V АС - Insulation voltage: 690V     - Surge voltage wear resistance : ≥8000V  - Electrical wear resistance (number of cycles): ≥ 1 000 000 - Mechanical wear resistance (number of cycles): ≥ 10 000 000 - Number of cycles per hour: 1200pcs up to 32А; 600pcs for 40-95А - Ambient temperature: -10°÷60ºС - Maximum altitude: 2000     Mounting:  on a DIN rail or using screws to flat surface in a vertical position with maximum incline of ±5°   Advantages: - Material: resistant to UV rays, self-extinguishing - High reliability of the current parameters - Suitable for using in highly contaminated operating environment - Secure separation of the power contacts - Easy mounting - Long life - Suitable for frequently switching ON/OFF consumers  Functions: - Switching ON/OFF of alternating current consumers in direct current controlling schemes  - Implementation of consumer control management                                                                             Applications: - Industry - Transport - Telecommunications   Standards:  EN 60947-1 EN 60947-4-1 LVD EMC

View Complete Details

Capacitor Switch Contactors

Technical Characteristics: -  Model: CJ19-43 -  Rated current: 32A/40A/65A/95A/115A/150A/170A - Operation class: AC6 - Insulation voltage: 690V - Rated operating voltage of the coil: 230/400V АC;50/60Hz - Surge voltage wear resistance: 8 000V - Electrical wear resistance ≥300 000 cycles - Mechanical wear resistance ≥1 000 000 cycles - Number of cycles per hour: up to 600 switchings - Number of contacts :3NO power contacts+1NO operative - Leking Power: up to 13W - Operating temperature: -10C÷+60C - Maximum altitude: 2000м   Mounting:   DIN rail or using screws to a flat surface in a vertical position with maximum incline of ±5°   Advantages: - Material: resistant to UV rays, self-extinguishing - High reliability of the current parameters - Secure separation of the power contacts - Secure part of the contactor against contact with the consumer - Manual switching on is not available Functions: - Switching on/off of capacitors for reactive energy compensation   - Developing of systems for compensation of reactive energy  - Lowering of peak transitional currents at switching on and switching off the capacitors    Applications: -  Industry - Administrative and public buildings   Standards: EN60947-1 EN60947-4-1 LVD EMC

View Complete Details

Module Contactors

  • Model K series
  • Rated current 20A/25A/40A/63A
  • Operation class АС 7a
  • Rated operating voltage of the controlling coil 230V АC; 50/60Hz
  • Rated operating voltage of the power circuit up to 690V АС
  • Number of power contacts 2-4
  • Insulation voltage 690V
  • Operating temperature -10C ÷ +60C
  • Maximum altitude 2000m

Mounting:  on a DIN rail/vertical position with maximum incline of ±5°   Advantages: •    High reliability of the current parameters •    Secure switching on or separation of the power contacts •    Compact sizes •    Low levels of operational noise •    Options for selection ot the type of power contacts •    Resistant to UV rays   Functions: •    Switching ON/OFF of electrical circuits under load •    Developing of systems for control of consumers  •    Operational element in control boards   Applications: •    Industry  •    Administrative and public buildings   Standards:   EN 61095  EMC LVD

View Complete Details

Reverse Contactors

  • Rated current 18A/25A/32A/40A/65A/95А
  • Operaton class АС3
  • Rated operating voltage of the controlling coil 230V АC; 50/60Hz
  • Rated operating voltage of the power circuit up to 690V АС
  • Insulation voltage 690V
  • Surge voltage wear resistance ≥8 000V

Number of contacts: 3 NO power contacts +1NO operating  (for contactors over 40А there is also auxiliary 1NC contact) - Electrical wear resistance (number of cycles):≥1 000 000 - Mechanical wear resistance (number of cycles):≥10 000 000 - Number of cycles per hour: up to 600 switchings - Ambient temperature : -10°÷60ºС - Maximum altitude: 2000m   Mounting:  on a DIN rail or using screws to flat surface in a vertical position with maximum incline of ±5°   Advantages: -  Material: resistant to UV rays, self-extinguishing - Switching ON of electrical motors in one direction of rotation and turning (reversing) of the rotation direction at outside command. - No option for simultaneous switching ON of the two contactors in the group due to mechanical interlock  - High reliability of the current parameters - Secure separation of the power contacts - Easy mounting  - Long life Functions:  - The contactor is used for reverse control of inductive motor with short circuited rotor.  - Developing of control systems   Applications:  -  Industry - Services   Standards: EN 60947-1 EN 60947-4-1 EMC LVD

View Complete Details

Time Delay Contact Block

  • Model LT02-Dxx
  • Operation class АС 3
  • Insulation voltage 690V
  • Number of contacts NO+NC
  • Time interval options 0.1-3s/0.1-30s/10-180s

Advantages: - Material: resistant to UV rays, self-extinguishing - Simultaneous switching with the other parts of the contact system of the contactor - Easy mounting - Long life Functions: - Increasing the number of the operative contacts of LT 1 K/D series contactors and star/delta starters. - Provide the time needed for the acceleration of the motor  Applications: - Industry  - Building construction - Administrative and public buildings   Standards:   EN60947-4-1 LVD EMC

View Complete Details

Frequency Inverters

  • Rated operating voltage 230/400V АС; 50 Hz
  • Tolerance of the operating voltage ±10%
  • Maximum output power 0.75-15.0 kW
  • Unbalance of phases < 3%
  • Frequency fluctuation < 5%
  • Output frequency 0 - 400 Hz
  • Output voltage from 0 to Uвх. max
  • Overload capacity constant: up to 110% momentary: up to 150% - Accuracy of the output frequncy adjustment: 0.1

 Output discrete control signal 24V  - Output analogue control signal: 0-10V  - Sliding compensation: from 0 to 20%  - Ambient temperature : -10°÷60ºС  - Maximum altitude: 2000m     Mounting:  - to a flat surface using screws  - mounting position – vertical with maximum incline up to ± 5º. When more than one inverter is mounted in a board it is recommendable to mount them next to each other, and when this is not possible, proper cooling of devices should be provided.   Advantages: -  DC - brake in static mode  - Dynamic breaking with external breaking resistor – used in inert electric motor load   - Output voltage setting option   - Option for activation of output safety functions  - Rotation speed increase – automatic and manual   - Adjustment of the V/F control curve – linear or quadratic   - Omission of resonance frequencies  - JOG function   - ‘counter’ function    - Automatic restart option in case of power supply failure   - 15- speed degrees control option   - Selection of control from the control panel; external or COM terminal   - Frequency control from the control panel, external potentiometer by current or by voltage   - Input signals on clockwise or counter-clockwise rotation, multi-step control, restart, etc.  - Function extending option: by including of additional modules   Functions:  Control of three phase inductive motors with a short circuited rotor    Applications:  Industry-conveyors, packing and lifting machines, mixers, pumps, compressors   Standards:   - EN 60898-1    - EN 60947-2  - LVD  - EMC

View Complete Details

Capacitor Batteries

  • Model HY 111
  • Capacity range 5-25kVAr
  • Operating voltage 450V, 690V
  • Insulation voltage 690V
  • Operating temperature -40°C ÷ +65°C
  • Capacity tolerance ±5%
  • Rated frequency: 50-60HZ
  • Level of discharge per minute 50V
  • Maximum altitude 2000m

Mounting:  via screws with sizes M12 and М16 to flat horizontal surface   Advantages: -  Used for correction of the power factor - Compensation of reactive energy - Reliable work - High overload resistance - Long life   Functions: -  Systems with high levels of harmonic distortion - Compensation of the reactive energy         Applications: -  Public buildings - Industry - Wind turbines   Standard: EN 60831-1 EN 60831-2

View Complete Details

Capacity Factor Regulator

  • Rated operating voltage 230/400V
  • Operating frequency 46-65HZ
  • Insulation voltage 690V
  • Measurement range 0-9999 kV
  • Operating temperature -10 ÷ +55 °С
  • Humidity 30-60%
  • Sensitivity 20mА
  • Maximum altitude 2500m

Mounting:  on the front panel of a board after an opening is cut   Advantages: -  Indication and setting parameters like power factor - Real time showing of many system parameters - Options for selection of manual and automatic operating mode   - Indication of overvoltage or lack of voltage - LED indication of displayed parameters and outputs in operation  - High level of security of data - Easy programming - Secure control of the outputs Functions: - Control of capacitors systems with 12/16 controlling outputs   Applications: - Industry  - Administrative and public buildings

View Complete Details

Quarz time switch with power reserve

  • Rated voltage: 230-240V AC 50/60Hz
  • Time range 24 hours
  • Min. programmable interval 15 minutes
  • Time adjustment manual
  • Battery power reserve 70 hours
  • Time deviation ± 1s (at 20°C)

  The mechanic relay for time is supposed to be used for managing chains with maximum capacity of 3500W.After the setting , the timer executes the functions we required in 24 hours regime. The minimum period for setting is 15 minutes as it is executed within 96 pcs segments which the timing of the work and rest of the consummator is being set.The timer is accomplished with a battery which assures the work by 70 hours after power failure.   Consumption: 2.5VA • Contact: 1NO • Contact capacity: • 16A/250V (COSФ=1) • 4A/250V (COSФ=0.6) • Electrical endurance: 10⁵ times • Mechanical endurance: 10⁷ times • Section of the conductor: rigid conductors up to 6mm²   MOUNTING: • DIN-rail  

View Complete Details

Digital Counter/Timer

  • Display LCD
  • Power supply voltage 230V; 50Hz
  • Counting range 0 - 999
  • Timer range 0.01 - 99h99m
  • Speed as counter 30/500 cps
  • Reset: outside impulse

Battery for programme storing: up to 10 years - Power consumption: - Mechanical wear resistance: 10 7  cycles - Operating temperature: -5 - +40°С - Humidity: 35 - 85%RH - Commutation capacity: relay output with active load: up to 3A - Weight: 120g   Mounting: - on the front panel - size of the opening 45х45   Standard:  EN 61010-1

View Complete Details

MES Current Transformer

  • Maximum operating voltage 720V, 50 Hz
  • Acceptable deviation of the operating current 1.2 х In
  • Input current 50 - 1200А
  • Output current
  • Surge voltage wear resistance 4000V, 50Hz (1 min)
  • Operating temperature -5 - + 65°С
  • Humidity 35 - 85%RH
  • Precision class: 0.5

View Complete Details

DIN-Rail Electricity Meters

  • Direct power consumption measurement up to 5(45)А, 50/60Hz

Technical characteristics: - Direct power consumption measurement: up to 5(45)А, 50/60Hz - Automatic temperature compensation - LED indicator for phase voltage  - Indication for wrong cable connection - Indication for wrong measurement  - Precision class: 1  - Number of tariffs: 1 - Meter constant: 1000 (imp/kWh)      

View Complete Details

Voltmeter/Amperemeter EKDP

  • Operating Temperature -5 - + 50°С
  • Power supply voltage 100-240V, 50Hz
  • Consumption < 5VА
  • Surge voltage wear resistance 4000V, 50Hz (1 min)
  • Humidity 35 - 85%RH
  • Accuracy 0.5% from the whole scale
  • Display LCD

Adjusted to measure:     direct current (AD, DV) values     alternating current (AA, VA) values - Input signal:     Operating as voltmeter : 2-700V (the range is adjusted from inside)     Operatind as amperemeter: 5-2000А (the range is adjusted from inside) Note: At current range over 5A a current measurement transformer should be used Mounting: - DIN rail Standard: EN 61010-1

View Complete Details

Limit Switch CSA

  • Dielectric Strength 1000V AC
  • Insulation Resistance 100mΩ
  • Electrical wear resistance (number of cycles): 500 000 at active load
  • Mechanical wear resistance (number of cycles) 1 000 000
  • Activation speed 5mm/s to 0.5m/s
  • Rated voltage 230V
  • Rated current up to 10А
  • IP code IP65
  • Ceble input cable gland PG11
  • Section of the power supply conductor to 2mm2
  • Fastening strength of terminals 6-8kgf/cm
  • Standards EN 60947-1; EN 60947-5-1

View Complete Details

Proximity Sensor

  • Activation distance 2-10mm
  • Output load 100-300 mA
  • Insulation resistance ≥ 50MΩ
  • Precision of repetition 0.01
  • Ambient temperature -25˚С до +70˚С
  • Activation speed 5mm/s
  • Rated voltage 6~36VDC; 90~230VAC
  • IP code IP 67

View Complete Details

Capacitive Sensors

  • Insulation resistance ≥ 50 МW
  • Activation distance 2-10 mm
  • Output load 100-300 mA
  • Precision of repetition 0.01
  • Ambient temperature -25˚С to +70˚С
  • Activation speed 5mm/s
  • Rated voltage 6~36VDC; 90~230VAC
  • IP code IP 54

View Complete Details

Photoelectrical Sensors

  • Insulation resistance ≥ 50
  • Start distance 9mm-10m
  • Output load 200 mA
  • Precision of repetition 0.01
  • Ambient temperature -25˚С до +70˚С
  • Activation speed 5mm/s
  • Rated voltage 6~36VDC; 90~230VAC
  • IP code IP 67
  • Activation distance from 2 to 7

View Complete Details

Power Supply Unit DRP

  • Power 25-240W
  • Input voltage 80~230V AC
  • Output voltage 5-24V AC
  • Tolerance 1,2%
  • Overload 120~120% of the rated power
  • Input 2 screw terminals
  • Output 4 screw terminals
  • IP code IP44

Power indicator  

View Complete Details

Float Switch DHC

  • Number of poles (levels) 1-3
  • Operating voltage 230V
  • Output load 4-6А

 Control of pumps with power up to 1 кW  

View Complete Details

Buttons and LED Indicators

  • Insulation voltage 660V; 50/60Hz
  • Surge volatge wear resistance 6000V
  • Rated current 6А (230V АС); 0.3А( 230V DC)
  • IP code IP20
  • Short circuit protection breaker 10А gG outside of the circuit
  • Mechanical wear resistance 1х106 commutation cycles
  • Operating temperature -20 - +70°С
  • Humidity 35 - 85%RH
  • Connecting wires torque 0.15 Nm
  • Section of the conductor 1х0.5; 1х0.75; 1х1; 1х1.5; 1х2.5mm2

Mounting: - To a flat metal or plastic surface with thickness: max 4m - Size of the opening: Ø22.5mm   Standards: EN 60947-1 EN 60947-5-1

View Complete Details

DIN-Rail Buttons and LEDs

  • Insulation voltage 660V; 50/60Hz
  • Surge voltage wear resistance 6000V
  • Rated current up to 10А (230V АС)
  • Short circuit protection breaker 10А gG outside of the circuit
  • Rated consumed current <20mA
  • Life (indicators) >2000h
  • Mechanical wear resistance 1х106 commutation cycles
  • Mechanical pressure strength At closing: 20N At opening: 8N
  • Operating temperature -20 - +70°С
  • Humidity 35 - 85%RH
  • Connecting wires torgue 0.15 Nm
  • Section of the conductor 1х0.5; 1х0.75; 1х1; 1х1.5; 1х2.5mm2

 Resistant to UV rays plastic Mounting: - DIN rail Standard: EN 60947-1 EN 60 947-5-1

View Complete Details

Hoist Control Devices

  • Power supply voltage 230V; 50/60Hz
  • Power consumption < 5VA
  • Electrical wear resistance 1х105 cycles
  • Operating temperature -10°С - +40°С
  • Humidity 35 - 85%RH
  • Number of buttons from 2 to 9

Type of buttons:one-speed and two-speed - Number of contacts: according to the number of the buttons - Commutation capacity: up to 6А - Resistant to UV rays plastic - IP code: IP65 - Weight: according to the number of contacts Mounting: - Directly to the control cable of the crane    

View Complete Details

Warning Lights and Towers

  • Rated voltage 12/230V, 50/60 Hz;
  • Insulation voltage 660V, 50/60 Hz;
  • Impulse voltage withstand 6000V
  • Rated power 6-28W
  • Short circuit protection 1A gG external fuse
  • Operating temperature -20°C - +70°C
  • Humidity 35-85% RH
  • Plastic cover UV resistant polycarbonate

Warning lights are offered individually in yellow, green and red colours, and the  warning towers – in a combination of up to 5 colours: green, yellow, red, blue and  white.

View Complete Details

Sirens and Alarms

  • Power supply voltage 12;24;110;230V
  • Power 60-160W
  • Sound level up to 120dB
  • Operating temperature -20°С ~ +70°С
  • Humidity 35–85%
  • Mounting wall/ceiling mounting

View Complete Details

Industrial Plugs and Sockets

  • Rated Voltage 500V
  • Rated Current 16-125А
  • Surge voltage wear resistance 8kV
  • Mechanical wear resistance 3000cycles
  • IP code IP44
  • Ambient temperature -5°С - +55°С
  • Altitude up to 2000m
  • Number of poles 3 / 4 / 5
  • Mounting flush / surface / movable / fixed

Advantages: - Made of special high quality plastic with alloys against aging at sun light  exposing and for in-creasing the mechanical strength - They provide reliable connection and high level of protection against electrical  current   Applications: - Industrial buildings - Electrical boards - Generators - Electrical motors   Standards: EN 60309-1; EN 60309-2    

View Complete Details

Plastic Distribution Boxes

  • Maximum insulation voltage 690V; 50Hz
  • Door colour Transparent
  • Mounting type Surface;Flush
  • Modules (№) 6; 9; 12; 16; 24; 36
  • IP code IP40
  • Row Single row for 6, 9, 12 and 16 modules

The distribution boxes are designed for mounting in newly built buildings or buildings in reconstruction. They are a module box with mounted protective devices of the given flats electrical current circuit circles. They are supplied with transparent door for each row opening upwards to 90°. They are made of white self-extinguishing plastic, resistant to heat and high temperature with IP code: IP 40. The mounted device in the box is protected from direct contact to the current leading parts. They are offered with DIN-rail for device mounting and terminal strips for the neutral and earthing conductor joining. Mounted directly on the walls with screws.   Double rows for 16; 24 and 36 modules • Material: ABS for body and PC for door • Fire resistance: 360°C/30s   Documents corresponding to the product: Standard EN 60670-24    

View Complete Details

Plastic distribution boards

  • Resistance chemical agents, weak acids, alkali, oils, salts, etc.
  • Rated Voltage up to 690V
  • Maximum Current up to 800A
  • Thermal Deformation over 240°C
  • Operating Temperature -35°C + 65°C
  • Material ABS
  • IP code IP65
  • Colour RAL7035 grey

Plastic distribution boards of various sizes. Intended for extension or distribution of cable lines. They can also be used as meter boxes. They are resistant to chemical agents, thermal and UV rays.    Recyclable • adjustable mounting plate position   MOUNTING: • Vertically on flat surface

View Complete Details

Power Cables

  • fixed installation -30°C to +50°C
  • Temperature of laying min. -5°C
  • Max. operating temperature +70°C
  • Short circuit temperature +160°C

• (short circuit duration up to 5 sec.) • Nominal voltage Uo/U- 0.6/1 kV • Test voltage: AC-4 kV/50 Hz Construction: • Solid or stranded Cu wires cl. 1 or cl. 2 acc. to DIN VDE 0295 • Insulation: PVC compound • Inner sheath: filling compound • Outer sheath: PVC compound • Outer sheath colour: black • re - round solid • rm - round multi-core • sm - sector multi-core • se - sector solid conductor Applications: Power cable for construction of underground distribution grids and installations of industrial and public projects, where mechanical damages are not to be expected. Suitable for transmission and distribution of electric power at nominal voltage u0/u 0, 6/1 kV. Standarts : DIN VDE 0293-308 - Colour coded acc DIN VDE 0276 part 603 or HD 186 DIN VDE 0295 - Wire class acc

View Complete Details

Flexible cables with PVC

  • Ambient temperature -40°C to+50°C
  • Max. operating temperature +70°C
  • Nominal voltage Uo/U 300/300 V
  • Test voltage 2000 V

Construction: Flexible Cu-wires, cl. 6 acc. to IEC 60228 Flat conductor acc. to BDS IEC 60227-5 Insulation: PVC compound Insulation colour: white or black-red   Applications: Designed for connection of electrical appliances to the electrical grid, for connection of mobile users, devices and appliances.   Standarts : Flat conductor acc. to BDS IEC 60227-5 Flexible Cu-wires, cl. 6 acc. to IEC 60228  

View Complete Details

Installation conductors

  • Ambient temperature -30°C to+50°C
  • Temperature of laying min. -5°C
  • Max. operating temperature +70°C
  • Nominal voltage Uo/U H05V-U 300/500 V - H07V-U 450/750 V
  • Test voltage H05V-U 2000 V - H07V-U 2500 V

Construction: • Solid Cu wires cl. 1 acc. to DIN VDE 0295, IEC 60228 • Insulation: PVC compound • Insulation colour: - yellow-green: available cross sections from 0.5 to 10 (mm²) - white: available cross sections from 0.5 to 4 (mm²) - black: available cross sections from 0.5 to 10 (mm²) - blue: available cross sections from 0.5 to 10 (mm²) - brown: available cross sections from 0.5 to 10 (mm²) - red: available cross sections from 0.5 to 10 (mm²)   Applications: For fixed installation in lighting networks, electric power installations, wiring of electrical switchboards, machines and equipment.   Standarts : Conductor acc. to HD 21.3 S3, DIN VDE 0281 part 3 Solid Cu wires cl. 1 acc. to DIN VDE 0295, IEC 60228

View Complete Details

Cables with rubber insulation

  • Conductor Material Copper (Cu) wires, class 5
  • Nominal voltage Uo/U 300V/500V
  • Ambient temperature from -30°C to +60°C
  • Conductors insulation Rubber EPR
  • Outer steath material Rubber EPR

Applications: For connection of electrical appliances and consumers with low and middle mechanical stress to Alternating Current (AC). It has wide use in household, office, for cable reels, for connecting of mobile consumers and etc.     Standarts :   DIN VDE 0295; IEC 60228- according to construction DIN VDE 0293-308 and HD 186- according to colour coating DIN VDE 0482-332-1-2; IEC60332-1- according to flame retardant

View Complete Details

Communication Cables

  • Ambient temperature -30°C to +50°C
  • Temperature of laying min. 0°C
  • Characteristic Impedance 100 Ω ± 15 Ω
  • Loop resisistance ≤ 192 0/ km
  • Unbalance of loop resistance ≤ 3%
  • Insulation resistance ≥ 150 MΩ x km
  • Operating capacity ≤ 55,8 nF/km
  • Cable diameter 5 mm

Construction : •  Solid  CCA  -wires - 24 AWG; 0, 51 mm, acc. to IEC 60228 • Insulation: PE compound • Cable bundle: 4 stranded pairs • Outer sheath: PVC compound or LSOH compound • Outer sheath colour: for PVC-grey   Applications: Cable, stranded by pairs, used for transmission of digital signals with high speed of transmission, with spectrumof the frequency being used up to 100 MHz for cat. 5 and up to 125 MHz for cat. 5e. Suitable for setting computer systems for data transmission, measuring and control systems with proper resistance to electromagnetic influences   Standarts : LAN cable acc. to ISO/IEC-11801/1995, IEC-1156/1995 ANSI/TIA/EIA - 568-A-5 Solid  CCA  -wires - 24 AWG; 0, 51 mm, acc. to IEC 60228

View Complete Details

Terminals without insulation GT

Technical Characteristics : Model:  GTL - Material: copper and aluminium alloy without galvanic coating - For conductors with sections from 16 to 240mm2 Model:  GTY - Material: copper alloy with galvanic tin coating  - For conductors with sections from 4 to 240mm2 Mounting:  by mechanical pressing using crimping pliers   Advantages: - Provide reliable connection even in the presence of vibrations - Protection against electrochemical corrosion - Long life - High quality Functions: - Connecting of copper and aluminium conductors   Applications : - Low voltage electricity distribution networks    Standard : EN 61238-1

View Complete Details

Isolated Cable Terminals

Technical Characteristics:   - Material: brass alloy with galvanic tin coating and insulated with polyvinylchloride - Colours: offered in three main colours: red, blue and yellow, as each colour corresponds to different section of multicore conductor   - For multicore cables with sections to 25 mm2 for the cable terminals type „Е“ and 6 mm2 for all the others   Mounting: by mechanical pressing using crimping pliers via mechanical pressing of the terminal and the cable.    Advantages: - The insulation of the terminals protects from direct contact with conductive parts and adjoining connections  - Easy and quick mounting - High quality and reliability - Wide range of application - Variety of options of terminals, as for each type, it is necessary to select the suitable pliers for pressing  Functions: - Connecting of multicore conductors without welding  - Mounting of multicore conductors in terminals and of switches,  thermoregulators, circuit breakers and other electrical devices   Applications: - Automotive industry - Mechanical engineering - Electricity distribution networks   Standards: EN 61 238-1

View Complete Details

Plastic Cable Trunking

Technical characteristics: - Material: non-flammable plastic - Length of the cable trunking: 2 m   - Sizes of the cable trunkings:      width: from 12mm to 100mm     height: from 10mm to 60mm   - Sizes of floor type cable trunkings:      50х12 / 75х20 / 90х20mm   - Sizes of step type cable trunkings:      width: from 25mm to 100mm     height: from 25mm to 60mm

View Complete Details

cable support systems

Technical data: Material- shock resistant technopolymer on PVC base Self-extinguishing V0 degree to UL94 Glow wire test: up to 960°C Standard- EN 61386-1; EN61386-21 RAL- 7035  

View Complete Details

Steel Cable Trays

  • width from 50mm to 300mm
  • height 40mm
  • depth 0,7 / 0,8mm

Length of the metal grate: 2, 5 m   Mounting : - horizontally or vertically to a flat surface  - hanging installation  

View Complete Details

Tell Us What are you looking for? Will call you back