Led Panels

  • Power Supply control gear, DC device - driver
  • Power 36W/40W
  • Rated voltage 230VAC
  • LED type SMD
  • Luminous flux 36W – 2400lm 40w - 3200lm 40W – 3200lm
  • Colour temperature 4000-4300К/6000-6400k(model only 45w-595x595mm)
  • Protection against dust and moisture IP40
  • Dimensions 36W – 595x595mm 40w - 595x595mm 40W – 1195x295mm

Housing: aesthetic aluminum frame, no change of color over time
- Diffuser: even distribution of lights, without formation of lighter or darker spots
- Installation: built-in / pendant kit available
- Long life: 15000 hours



Application areas:


- Residential buildings
- Commercial buildings
- Administrative buildings
- Banks
- Hospitals
- Schools



Benefits:


- Completely replace traditional fluorescent lighting
- Safety, low voltage operation
- Installation options: suspended ceilings, artificial walls, pendant mounting
- Emit a very pleasant and even light with very low glare factor due to the diffusion lens
- Low power consumption
- Repeated switch-on/off does not affect the lifespan of the LED panel
- Instant light with maximum luminous flux
- Environmentally friendly - do not emit mercury and lead (RoHS Directive)
- No ultraviolet and infrared rays
- Resistant to shock and vibration

View Complete Details

Wall Washer STREAM

  • Color Temperature 5500K
  • Power 9W/18W/36W
  • Rated voltage 85V – 265V
  • Power supply low-voltage, direct-current device - driver
  • LED type High power
  • Luminous flux STREAM 9W – 720lm STREAM 18W – 1440lm STREAM 36W – 2880lm
  • Protection against dust and moisture IP65

Housing: aluminum body
- Colour of the housing: grey
- Resistance: -40C +65C
- Long life: 30000 hours


Application area:
- Sports halls
- Commercial areas
- Warehouses
- Production facilities
- Squares
- Fleets
- Parking lots



Benefits:
- Efficient replacement of traditional halogen and metal-halide floodlights
- Wide distribution of even and stable light
- Economic- low power consumption
- Repeated switch on/off does not effect the fixture lifespan
- Instant light at maximum luminous flux
- Environmentally friendly - no mercury and lead
- No ultraviolet and infrared rays
- Resistant to shock and vibration stable body
- Voltage supply fluctuations do not affect the normal operation of the floodlights

View Complete Details

HRC Fuse Links And Bases

  • Rated voltage 500V
  • Rated short circuit current from 16А to 630А
  • Dimensions NT00 / NT0 / NT1 / NT2 / NT3

Direct mounting to the load
- IP code: IP 00
- Porcelain/dielectric alloy
- Ambient temperature: - 5 to +55



Mounting:


- Via bolts to the mounting plate



Standards:


EN 60269-2
EN 60269-1
IEC269-2


View Complete Details

Cylindrical Fuse Links

  • Rated voltage 500V
  • Rated short circuit current from 1А to 63А
  • Ambient temperature -5° до +55°С
  • Dimensions 10х38 / 14х51
  • Class gG

Standard:
EN 60269-2;
IEC269-2
EN 60269-1


View Complete Details

Manual Change-Over Switch

  • Rated operating voltage not higher than 660V; 50/60Hz
  • Rated current 160-800А
  • Insulation voltage ≥1000V
  • Number of poles 3, 4
  • IP code IP>20

Mounting: to a flat surface using bolts



Advantages:
- Resistant to high voltages
- Option for moving the handle on the front panel of the board
- High mechanical endurance and wear resistance
- Not affected by the frequency variations
- Reliable and secure control
- Long life



Functions:
- For mounting in main electrical boards for breaking of the circuits
- Manual switching between two power supplies
- Switching ON of generators
- Used as main switch



Applications:
- Industry
- Administrative and public buildings
- Building construction



Standards:
N 60947- 1
EN 60947-3

View Complete Details

Automatic Switch EQ1

  • Rated Current 100-630А
  • Rated operating voltage 690V; 50/60Hz
  • IP code IP21
  • Surge voltage wear resistance ≥6 000V

Mounting: vertically on a flat surface using bolts



Advantages:
- Selection between device with integrated and separated controller
- Option for setting the change-over time between the two sources min 3s
- Option for automatic switch-over to the main power supply source after restoring its parameters
- High reliability, safety and long life



Functions:


- Provide continuous power supply and two electrical sources automatic switch in case of failure or deviation from the set parameters
- Control the status of the circuit parameters:
presence of the three phases
limits of the phase voltage
overload
short circuit at the output
- Switching to dual power change-over at power supply phase lack
- Breaking of electrical circuits and control of powerful consumers
- Main breaker in housing or industrial distributing installations supplied with a generator or with a second power supply source



Applications:


- Administrative and public buildings-hospitals, military sites, control rooms
- Industry-productions requiring continuity of the process
- Generators


Standards:
EN 60947-1
EN 60947-2
EN 60947-6-1

View Complete Details

Under Voltage Release













The device switches off and/or does not allow the switching on of the breaker to which it is mounted at

power breakdown or voltage decrease under certain limits




TECHNICAL DATA:



operating voltage: 230/400V 50Hz

electromagnetic coil 6VA for breakers up to 400A

electromagnetic coil 10VA for breakers 630-800A

available joining conductors

switches off at voltage decrease under 75% of the

operating




MOUNTING:



Mounted in a special jack after cover dismounting

Note: The breakers are offered with mounted

accessory








CONNECTING:



Connected with the operative system through the

provided conductors

View Complete Details

Terminal Plates For MCCB

Straight copper electro-tinned extensions enabling cable connection outside the switch terminals and providing

excellent contact with the switch terminal base. Terminal extensions with different cross section are available

depending on the switch rated power.


MOUNTING:

Extensions are directly bolt mounted to the switch terminal base
View Complete Details

Remote Control (manual)

The device switches off/on the breaker to whichmanual operative rotary mechanism is mounted

two operating positions of the executive mechanismfixed at 90C



Mounting:


The base is mounted with bolts right on the cover (scheme 1 mounting), and the handle is mounted at

the door of the distribution box, using an extension axis it is joined to the base

View Complete Details

Contactors LP1

Technical characteristics:


- Rated current: from 9A up to 225
- Rated operating voltage of the controlling coil: 12V DC to 230V DC
- Rated operating voltage of the power circuit: up to 690V
- Insulation voltage: 690V
- Surge voltage wear resistance : 8000V
- Electrical wear resistance (number of cycles): 1 000 000
- Mechanical wear resistance (number of cycles): 10 000 000
- Number of cycles per hour: 1200pcs up to 32; 600pcs for 40-95
- Ambient temperature: -1060
- Maximum altitude: 2000



Mounting:on a DIN rail or using screws to flat surface in a vertical position with maximum incline of 5



Advantages:
- Material: resistant to UV rays, self-extinguishing
- High reliability of the current parameters
- Suitable for using in highly contaminated operating environment
- Secure separation of the power contacts
- Easy mounting
- Long life
- Suitable for frequently switching ON/OFF consumers



Functions:
- Switching ON/OFF of alternating current consumers in direct current controlling schemes
- Implementation of consumer control management


Applications:
- Industry
- Transport
- Telecommunications



Standards:
EN 60947-1
EN 60947-4-1
LVD
EMC

View Complete Details

Capacitor Switch Contactors

Technical Characteristics:


- Model: CJ19-43


- Rated current: 32A/40A/65A/95A/115A/150A/170A
- Operation class: AC6
- Insulation voltage: 690V
- Rated operating voltage of the coil: 230/400V C;50/60Hz
- Surge voltage wear resistance:8 000V
- Electrical wear resistance 300 000 cycles
- Mechanical wear resistance 1 000 000 cycles
- Number of cycles per hour: up to 600 switchings
- Number of contacts :3NO power contacts+1NO operative
- Leking Power: up to 13W
- Operating temperature: -10C+60C
- Maximum altitude: 2000



Mounting:
DIN rail or using screws to a flat surface in a vertical position with maximum incline of 5



Advantages:
- Material: resistant to UV rays, self-extinguishing
- High reliability of the current parameters
- Secure separation of the power contacts
- Secure part of the contactor against contact with the consumer
- Manual switching on is not available



Functions:
- Switching on/off of capacitors for reactive energy compensation
- Developing of systems for compensation of reactive energy
- Lowering of peak transitional currents at switching on and switching off the capacitors



Applications:


- Industry
- Administrative and public buildings



Standards:
EN60947-1
EN60947-4-1
LVD
EMC

View Complete Details

Module Contactors

  • Model Number K series
  • Operating Temperature -10C ÷ +60C
  • Rated current 20A/25A/40A/63A
  • Operation class АС 7a
  • Rated operating voltage of the controlling coil 230V АC; 50/60Hz
  • Rated operating voltage of the power circuit up to 690V АС
  • Number of power contacts 2-4
  • Insulation voltage 690V
  • Maximum altitude 2000m

Mounting:on a DIN rail/vertical position with maximum incline of 5



Advantages:


High reliability of the current parameters
Secure switching on or separation of the power contacts
Compact sizes
Low levels of operational noise
Options for selection ot the type of power contacts
Resistant to UV rays



Functions:


Switching ON/OFF of electrical circuits under load
Developing of systems for control of consumers
Operational element in control boards



Applications:


Industry
Administrative and public buildings



Standards:
EN 61095
EMC
LVD

View Complete Details

Reverse Contactors

  • Rated current 18A/25A/32A/40A/65A/95А
  • Operaton class АС3
  • Rated operating voltage of the controlling coil 230V АC; 50/60Hz
  • Rated operating voltage of the power circuit up to 690V АС
  • Insulation voltage 690V
  • Surge voltage wear resistance ≥8 000V

Number of contacts: 3 NO power contacts +1NO operating
(for contactors over 40 there is also auxiliary 1NC contact)
- Electrical wear resistance (number of cycles):1 000 000
- Mechanical wear resistance (number of cycles):10 000 000
- Number of cycles per hour: up to 600 switchings
- Ambient temperature : -1060
- Maximum altitude: 2000m



Mounting:on a DIN rail or using screws to flat surface in a vertical position with maximum incline of 5



Advantages:


- Material: resistant to UV rays, self-extinguishing
- Switching ON of electrical motors in one direction of rotation and turning (reversing) of the rotation direction at outside command.
- No option for simultaneous switching ON of the two contactors in the group due to mechanical interlock
- High reliability of the current parameters
- Secure separation of the power contacts
- Easy mounting
- Long life



Functions:
- The contactor is used for reverse control of inductive motor with short circuited rotor.
- Developing of control systems



Applications:


- Industry
- Services



Standards:
EN 60947-1
EN 60947-4-1
EMC
LVD

View Complete Details

Frequency Inverters

  • Rated operating voltage 230/400V АС; 50 Hz
  • Tolerance of the operating voltage ±10%
  • Maximum output power 0.75-15.0 kW
  • Unbalance of phases < 3%
  • Frequency fluctuation < 5%
  • Output frequency 0 - 400 Hz
  • Output voltage from 0 to Uвх. max
  • Overload capacity constant: up to 110% momentary: up to 150% - Accuracy of the output frequncy adjustment: 0.1

Output discrete control signal 24V


- Output analogue control signal: 0-10V


- Sliding compensation: from 0 to 20%


- Ambient temperature : -1060


- Maximum altitude: 2000m



Mounting:


- to a flat surface using screws


- mounting position vertical with maximum incline up to 5. When more than one inverter is mounted in a board it is recommendable to mount them next to each other, and when this is not possible, proper cooling of devices should be provided.

Advantages:
- DC - brake in static mode


- Dynamic breaking with external breaking resistor used in inert electric motor load


- Output voltage setting option


- Option for activation of output safety functions


- Rotation speed increase automatic and manual


- Adjustment of the V/F control curve linear or quadratic


- Omission of resonance frequencies


- JOG function


- counter function


- Automatic restart option in case of power supply failure


- 15- speed degrees control option


- Selection of control from the control panel; external or COM terminal


- Frequency control from the control panel, external potentiometer by current or by voltage


- Input signals on clockwise or counter-clockwise rotation, multi-step control, restart, etc.


- Function extending option: by including of additional modules

Functions:


Control of three phase inductive motors with a short circuited rotor

Applications:


Industry-conveyors, packing and lifting machines, mixers, pumps, compressors

Standards:


- EN 60898-1


- EN 60947-2


- LVD


- EMC

View Complete Details

Capacitor Batteries

  • Model HY 111
  • Capacity range 5-25kVAr
  • Operating voltage 450V, 690V
  • Insulation voltage 690V
  • Operating temperature -40°C ÷ +65°C
  • Capacity tolerance ±5%
  • Rated frequency: 50-60HZ
  • Level of discharge per minute 50V
  • Maximum altitude 2000m

Mounting:via screws with sizes M12 and 16 to flat horizontal surface



Advantages:


- Used for correction of the power factor
- Compensation of reactive energy
- Reliable work
- High overload resistance
- Long life



Functions:


- Systems with high levels of harmonic distortion
- Compensation of the reactive energy

Applications:


- Public buildings
- Industry
- Wind turbines



Standard:
EN 60831-1
EN 60831-2

View Complete Details

Capacity Factor Regulator

  • Rated operating voltage 230/400V
  • Operating frequency 46-65HZ
  • Insulation voltage 690V
  • Measurement range 0-9999 kV
  • Operating temperature -10 ÷ +55 °С
  • Humidity 30-60%
  • Sensitivity 20mА
  • Maximum altitude 2500m

Mounting:on the front panel of a board after an opening is cut



Advantages:


- Indication and setting parameters like power factor
- Real time showing of many system parameters
- Options for selection of manual and automatic operating mode
- Indication of overvoltage or lack of voltage
- LED indication of displayed parameters and outputs in operation
- High level of security of data
- Easy programming
- Secure control of the outputs



Functions:
- Control of capacitors systems with 12/16 controlling outputs



Applications:
- Industry
- Administrative and public buildings

View Complete Details

Quarz Time Switch With Power Reserve

  • Rated voltage: 230-240V AC 50/60Hz
  • Time range 24 hours
  • Min. programmable interval 15 minutes
  • Time adjustment manual
  • Battery power reserve 70 hours
  • Time deviation ± 1s (at 20°C)








The mechanic relay for time is supposed to be used for managing chains with maximum capacity of 3500W.After
the setting , the timer executes the functions we required in 24 hours regime. The minimum period for setting is
15 minutes as it is executed within 96 pcs segments which the timing of the work and rest of the consummator is
being set.The timer is accomplished with a battery which assures the work by 70 hours after power failure.










Consumption: 2.5VA
Contact: 1NO
Contact capacity:
16A/250V (COS=1)
4A/250V (COS=0.6)
Electrical endurance: 10 times
Mechanical endurance: 10 times
Section of the conductor: rigid conductors up to
6mm




MOUNTING:
DIN-rail



View Complete Details

Digital Counter/Timer

  • Display LCD
  • Power supply voltage 230V; 50Hz
  • Counting range 0 - 999
  • Timer range 0.01 - 99h99m
  • Speed as counter 30/500 cps
  • Reset: outside impulse

Battery for programme storing: up to 10 years
- Power consumption: < 3VA
- Mechanical wear resistance: 107cycles
- Operating temperature: -5 - +40
- Humidity: 35 - 85%RH
- Commutation capacity: relay output with active load: up to 3A
- Weight: 120g



Mounting:
- on the front panel
- size of the opening 4545



Standard:EN 61010-1

View Complete Details

MES Current Transformer

  • Maximum operating voltage 720V, 50 Hz
  • Acceptable deviation of the operating current 1.2 х In
  • Input current 50 - 1200А
  • Output current
  • Surge voltage wear resistance 4000V, 50Hz (1 min)
  • Operating temperature -5 - + 65°С
  • Humidity 35 - 85%RH
  • Precision class: 0.5
View Complete Details

DIN-Rail Electricity Meters

  • Direct power consumption measurement up to 5(45)А, 50/60Hz

Technical characteristics:
- Direct power consumption measurement: up to 5(45), 50/60Hz
- Automatic temperature compensation
- LED indicator for phase voltage
- Indication for wrong cable connection
- Indication for wrong measurement
- Precision class: 1
- Number of tariffs: 1
- Meter constant: 1000 (imp/kWh)




View Complete Details

Voltmeter/Amperemeter EKDP

  • Operating Temperature -5 - + 50°С
  • Power supply voltage 100-240V, 50Hz
  • Consumption < 5VА
  • Surge voltage wear resistance 4000V, 50Hz (1 min)
  • Humidity 35 - 85%RH
  • Accuracy 0.5% from the whole scale
  • Display LCD

Adjusted to measure:
direct current (AD, DV) values
alternating current (AA, VA) values
- Input signal:
Operating as voltmeter : 2-700V (the range is adjusted from inside)
Operatind as amperemeter: 5-2000 (the range is adjusted from inside)


Note: At current range over 5A a current measurement transformer should be used


Mounting:
- DIN rail



Standard:
EN 61010-1

View Complete Details

Limit Switch CSA

  • Dielectric Strength 1000V AC
  • Rated Voltage 230V
  • Insulation Resistance 100mΩ
  • Electrical wear resistance (number of cycles): 500 000 at active load
  • Mechanical wear resistance (number of cycles) 1 000 000
  • Activation speed 5mm/s to 0.5m/s
  • Rated current up to 10А
  • IP code IP65
  • Ceble input cable gland PG11
  • Section of the power supply conductor to 2mm2
  • Fastening strength of terminals 6-8kgf/cm
  • Standards EN 60947-1; EN 60947-5-1
View Complete Details

Proximity Sensor

  • Activation distance 2-10mm
  • Output load 100-300 mA
  • Insulation resistance ≥ 50MΩ
  • Precision of repetition 0.01
  • Ambient temperature -25˚С до +70˚С
  • Activation speed 5mm/s
  • Rated voltage 6~36VDC; 90~230VAC
  • IP code IP 67
View Complete Details

Capacitive Sensors

  • Insulation resistance ≥ 50 МW
  • Activation distance 2-10 mm
  • Output load 100-300 mA
  • Precision of repetition 0.01
  • Ambient temperature -25˚С to +70˚С
  • Activation speed 5mm/s
  • Rated voltage 6~36VDC; 90~230VAC
  • IP code IP 54
View Complete Details

Photoelectrical Sensors

  • Insulation resistance ≥ 50
  • Start distance 9mm-10m
  • Output load 200 mA
  • Precision of repetition 0.01
  • Ambient temperature -25˚С до +70˚С
  • Activation speed 5mm/s
  • Rated voltage 6~36VDC; 90~230VAC
  • IP code IP 67
  • Activation distance from 2 to 7
View Complete Details

Power Supply Unit DRP

  • Power 25-240W
  • Input voltage 80~230V AC
  • Output voltage 5-24V AC
  • Tolerance 1, 2%
  • Overload 120~120% of the rated power
  • Input 2 screw terminals
  • Output 4 screw terminals
  • IP code IP44

Power indicator


View Complete Details

Float Switch DHC

  • Number of poles (levels) 1-3
  • Operating voltage 230V
  • Output load 4-6А

Control of pumps with power up to 1 W


View Complete Details

Buttons And LED Indicators

  • Insulation voltage 660V; 50/60Hz
  • Surge volatge wear resistance 6000V
  • Rated current 6А (230V АС); 0.3А( 230V DC)
  • IP code IP20
  • Short circuit protection breaker 10А gG outside of the circuit
  • Mechanical wear resistance 1х106 commutation cycles
  • Operating temperature -20 - +70°С
  • Humidity 35 - 85%RH
  • Connecting wires torque 0.15 Nm
  • Section of the conductor 1х0.5; 1х0.75; 1х1; 1х1.5; 1х2.5mm2

Mounting:
- To a flat metal or plastic surface with thickness: max 4m
- Size of the opening: 22.5mm



Standards:
EN 60947-1
EN 60947-5-1

View Complete Details

DIN-Rail Buttons And LEDs

  • Insulation voltage 660V; 50/60Hz
  • Surge voltage wear resistance 6000V
  • Rated current up to 10А (230V АС)
  • Short circuit protection breaker 10А gG outside of the circuit
  • Rated consumed current <20mA
  • Life (indicators) >2000h
  • Mechanical wear resistance 1х106 commutation cycles
  • Mechanical pressure strength At closing: 20N At opening: 8N
  • Operating temperature -20 - +70°С
  • Humidity 35 - 85%RH
  • Connecting wires torgue 0.15 Nm
  • Section of the conductor 1х0.5; 1х0.75; 1х1; 1х1.5; 1х2.5mm2

Resistant to UV rays plastic



Mounting:
- DIN rail



Standard:
EN 60947-1
EN 60 947-5-1

View Complete Details

Hoist Control Devices

  • Power supply voltage 230V; 50/60Hz
  • Power consumption < 5VA
  • Electrical wear resistance 1х105 cycles
  • Operating temperature -10°С - +40°С
  • Humidity 35 - 85%RH
  • Number of buttons from 2 to 9

Type of buttons:one-speed and two-speed
- Number of contacts: according to the number of the buttons
- Commutation capacity: up to 6
- Resistant to UV rays plastic
- IP code: IP65
- Weight: according to the number of contacts



Mounting:
- Directly to the control cable of the crane



View Complete Details

Warning Lights And Towers

  • Rated voltage 12/230V, 50/60 Hz;
  • Insulation voltage 660V, 50/60 Hz;
  • Impulse voltage withstand 6000V
  • Rated power 6-28W
  • Short circuit protection 1A gG external fuse
  • Operating temperature -20°C - +70°C
  • Humidity 35-85% RH
  • Plastic cover UV resistant polycarbonate

Warning lights are offered individually in yellow, green and red colours, and thewarning towers in a combination of up to 5 colours: green, yellow, red, blue andwhite.

View Complete Details

Sirens And Alarms

  • Power supply voltage 12;24;110;230V
  • Power 60-160W
  • Sound level up to 120dB
  • Operating temperature -20°С ~ +70°С
  • Humidity 35–85%
  • Mounting wall/ceiling mounting
View Complete Details

Plastic Distribution Boxes

  • Maximum insulation voltage 690V; 50Hz
  • Door colour Transparent
  • Mounting type Surface;Flush
  • Modules (№) 6; 9; 12; 16; 24; 36
  • IP code IP40
  • Row Single row for 6, 9, 12 and 16 modules

The distribution boxes are designed for mounting in newly built buildings or buildings in reconstruction.
They are a module box with mounted protective devices of the given flats electrical current circuit
circles. They are supplied with transparent door for each row opening upwards to 90. They are made of
white self-extinguishing plastic, resistant to heat and high temperature with IP code: IP 40. The mounted
device in the box is protected from direct contact to the current leading parts. They are offered with
DIN-rail for device mounting and terminal strips for the neutral and earthing conductor joining. Mounted
directly on the walls with screws.



Double rows for 16; 24 and 36 modules
Material: ABS for body and PC for door
Fire resistance: 360C/30s



Documents corresponding to the product:
Standard EN 60670-24



View Complete Details

Plastic Distribution Boards

  • Material ABS
  • Resistance chemical agents, weak acids, alkali, oils, salts, etc.
  • Rated Voltage up to 690V
  • Maximum Current up to 800A
  • Thermal Deformation over 240°C
  • Operating Temperature -35°C + 65°C
  • IP code IP65
  • Colour RAL7035 grey

Plastic distribution boards of various sizes. Intended for extension or distribution of cable lines. They can also be
used as meter boxes. They are resistant to chemical agents, thermal and UV rays.



Recyclable
adjustable mounting plate position




MOUNTING:
Vertically on flat surface

View Complete Details

Power Cables

  • fixed installation -30°C to +50°C
  • Temperature of laying min. -5°C
  • Max. operating temperature +70°C
  • Short circuit temperature +160°C

(short circuit duration up to 5 sec.)


Nominal voltage Uo/U- 0.6/1 kV


Test voltage: AC-4 kV/50 Hz


Construction:


Solid or stranded Cu wires cl. 1 or cl. 2 acc. to DIN VDE 0295


Insulation: PVC compound


Inner sheath: filling compound


Outer sheath: PVC compound


Outer sheath colour: black


re - round solid


rm - round multi-core


sm - sector multi-core


se - sector solid conductor


Applications:


Power cable for construction of underground distribution grids and installations of industrial and public projects, where mechanical damages are not to be expected. Suitable for transmission and distribution of electric power at nominal voltage u0/u 0, 6/1 kV.


Standarts:


DIN VDE 0293-308 - Colour coded acc


DIN VDE 0276 part 603 or HD 186


DIN VDE 0295 - Wire class acc

View Complete Details

Flexible Cables With PVC

  • Ambient temperature -40°C to+50°C
  • Max. operating temperature +70°C
  • Nominal voltage Uo/U 300/300 V
  • Test voltage 2000 V

Construction:



  • Flexible Cu-wires, cl. 6 acc. to IEC 60228

  • Flat conductor acc. to BDS IEC 60227-5

  • Insulation: PVC compound

  • Insulation colour: white or black-red



Applications:


Designed for connection of electrical appliances to the electrical grid, for connection of mobile users, devices and appliances.



Standarts:


Flat conductor acc. to BDS IEC 60227-5


Flexible Cu-wires, cl. 6 acc. to IEC 60228


View Complete Details

Installation Conductors

  • Ambient Temperature -30°C to+50°C
  • Temperature of laying min. -5°C
  • Max. operating temperature +70°C
  • Nominal voltage Uo/U H05V-U 300/500 V - H07V-U 450/750 V
  • Test voltage H05V-U 2000 V - H07V-U 2500 V

Construction:


Solid Cu wires cl. 1 acc. to DIN VDE 0295, IEC 60228


Insulation: PVC compound


Insulation colour:


- yellow-green: available cross sections from 0.5 to 10 (mm)


- white: available cross sections from 0.5 to 4 (mm)


- black: available cross sections from 0.5 to 10 (mm)


- blue: available cross sections from 0.5 to 10 (mm)


- brown: available cross sections from 0.5 to 10 (mm)


- red: available cross sections from 0.5 to 10 (mm)



Applications:


For fixed installation in lighting networks, electric power installations, wiring of electrical switchboards, machines and equipment.



Standarts:


Conductor acc. to HD 21.3 S3, DIN VDE 0281 part 3


Solid Cu wires cl. 1 acc. to DIN VDE 0295, IEC 60228

View Complete Details

Cables With Rubber Insulation

  • Conductor Material Copper (Cu) wires, class 5
  • Nominal voltage Uo/U 300V/500V
  • Ambient temperature from -30°C to +60°C
  • Conductors insulation Rubber EPR
  • Outer steath material Rubber EPR

Applications:


For connection of electrical appliances and consumers with low and middle mechanical stress to Alternating Current (AC). It has wide use in household, office, for cable reels, for connecting of mobile consumers and etc.




Standarts:



DIN VDE 0295; IEC 60228- according to construction


DIN VDE 0293-308 and HD 186- according to colour coating


DIN VDE 0482-332-1-2; IEC60332-1- according to flame retardant

View Complete Details

Communication Cables

  • Ambient temperature -30°C to +50°C
  • Temperature of laying min. 0°C
  • Characteristic Impedance 100 Ω ± 15 Ω
  • Loop resisistance ≤ 192 0/ km
  • Unbalance of loop resistance ≤ 3%
  • Insulation resistance ≥ 150 MΩ x km
  • Operating capacity ≤ 55, 8 nF/km
  • Cable diameter 5 mm

Construction:


SolidCCA-wires - 24 AWG; 0, 51 mm, acc. to IEC 60228
Insulation: PE compound
Cable bundle: 4 stranded pairs
Outer sheath: PVC compound or LSOH compound
Outer sheath colour: for PVC-grey



Applications:
Cable, stranded by pairs, used for transmission of digital signals with high speed of transmission, with spectrumof the frequency being used up to 100 MHz for cat. 5 and up to 125 MHz for cat. 5e. Suitable for setting computer systems for data transmission, measuring and control systems with proper resistance to electromagnetic influences



Standarts:


LAN cable acc. to ISO/IEC-11801/1995, IEC-1156/1995


ANSI/TIA/EIA - 568-A-5 SolidCCA-wires - 24 AWG; 0, 51 mm, acc. to IEC 60228

View Complete Details

Plastic Cable Trunking

Technical characteristics:
- Material: non-flammable plastic
- Length of the cable trunking: 2 m



- Sizes of the cable trunkings:
width: from 12mm to 100mm
height: from 10mm to 60mm



- Sizes of floor type cable trunkings:
5012 / 7520 / 9020mm


- Sizes of step type cable trunkings:
width: from 25mm to 100mm
height: from 25mm to 60mm

View Complete Details

Cable Support Systems

Technical data:



Material- shock resistant technopolymer on PVC base
Self-extinguishing V0 degree to UL94
Glow wire test: up to 960C


Standard- EN 61386-1; EN61386-21
RAL- 7035


View Complete Details

Steel Cable Trays

  • width from 50mm to 300mm
  • height 40mm
  • depth 0, 7 / 0, 8mm

Length of the metal grate: 2, 5 m



Mounting:


- horizontally or vertically to a flat surface


- hanging installation


View Complete Details

Boxes For Switches And Sockets

Technical characteristics:



- Console boxes: 65mm


- Junction boxes: SQUARE88 / 1010 mm


- Junction boxes: ROUND 65 / 70 / 80



Mounting:wall/plasterboard built-in mounting

View Complete Details

Waterproof Junction Boxes

  • Material ABS
  • Rated operating voltage up to 1000V
  • IP code IP44/IP54
  • Mounting surface

Model:
Round: 50 / 80

Square:
width: from 85mm to 400mm
height: from 85mm to 350mm
depth: from 50mm to 120mm



Standard:
- EN 60670-1

View Complete Details

Supply Busbar

  • rated operating voltage 230V/400V
  • isolating voltage 500V
  • rated current 63/100A
  • resistance 960°C/3sec
View Complete Details

Zero Rails And Terminals

Technical Specifications:


- brass elements


- plastic insulation material


- color: grey/blue


- ambient temperature: -40C+85C


View Complete Details

Din Rails

Technical Characteristics:


- electroplated brass alloy


- pre- cut slotted holes


- lenght: 1m


View Complete Details

Insulating Mounting Terminal

  • rated voltage 230V
  • rated current: up to 63A
  • isolating voltage ≥500V
  • protection IP20
  • power supply conductor cut 2.5 to 35mm2

Technical Characteristics:


- electroplated brass alloy


- plastic insulation cover

View Complete Details

Support Insulator SM

  • rated voltage 1000V
  • insulated voltage 5000V
  • ambient temperature -40°C ÷ +90°C
View Complete Details

Heat Shrinkage Tubes

  • Material triple cross-linked polyolefin
  • Shrinkage temperature min 120°C
  • Insulation resistance 1х 10 12 Ω/cm
  • Shrinkage ratio min 2 : 1
  • Ambient temperature -40 to + 100°C
  • Insulating voltage 1000 V

Advantages:


- High temperature resistance
- UV rays wear resistance
- Easy to use
- Reliable insulation
- Protects conductors from moisture, water and corrosion



Applications:


- Insulation of cable connection
- Industrial and home electronics
- Equipment of electrical boards
- Repairs of household appliances



Standard:


- European Union safety regulations and CE marking
- Standard: EN 60684


View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • ELMARK GROUP (ELMARK GROUP)
  • Post Box 341086 Dubai Silicon Oasis, Dubai,UAE
  • Share us via