Post Buy Requirement
GS
Dubai, United Arab Emirates
Add Review

Other Products / Services #5737434

Fire Suppression Systems

Fire suppression systems are used in conjunction with smoke detectors and fire alarm systems to improve and increase public safety. Suppression systems are governed by the codes under the NFPA 13 handbook.High value assets are protected with carbon dioxide, FM-200, Inergen, Argonite or water mist. Guardian will evaluate and advise the right system for your needs.
Guardian Safety & Security LLC designs, supplies and installs Fire Hydrant Systems and Fire Pumps according to NFPA standards and in full compliance with the Civil Defense requirements
View Complete Details

Fire Alarm Systems

Fire alarm systems offer early detection in case of fire to evacuate the building and alert the fire department. An automatic fire alarm system is designed to detect the unwanted presence of fire by monitoring environmental changes associated with combustion. In general, a fire alarm system is either classified as automatically actuated, manually actuated, or both. Automatic fire alarm systems can be used to notify people to evacuate in the event of a fire or other emergency, to summon emergency services, and to prepare the structure and associated systems to control the spread of fire and smoke.
Guardian Safety & Security LLC designs, supplies and installs Fire Alarm systems according to NFPA 72 standards and in full compliance with the Civil Defense requirements.
View Complete Details

Kitchen Suppression Systems

Commercial kitchen environments pose an extra high risk for fire and therefore require extra protection. Protect your employees, equipment and business continuity with a Wet Chemical Kitchen Suppression System.
Guardian Safety & Security LLC supplies, installs and maintain kitchen hood suppression systems as per NFPA 96 standards and in full compliance with the Civil Defense requirements.
View Complete Details

Dry And Wet Risers

Dry and wet rising mains are intended for use by the fire brigade or other trained personnel. Dry risers are vertical mains fitted into staircase enclosures or other suitable positions, constructed of 4'' galvanized steel throughout with outlet valves on each floor and an inlet fitted at ground level to enable the fire brigade to connect to the water supply. Wet risers are pipes kept permanently charged with water either from a storage tank (via a booster pump) or direct from the town's main water supply. A dry riser is a main vertical pipe intended to distribute water to multiple levels of a building or structure as a component of the fire suppression systems. The pipe is maintained empty of water. The dry riser is the opposite of a "wet riser" or "wet standpipe" system where the pipes are kept full of water for manual or automatic fire fighting operations. Dry risers have to have fire engine access within 18m of the dry riser inlet box.

View Complete Details

Pre Action System

In a pre-action system the piping is pressurized with air or nitrogen, monitoring of this air pressure provides a means of supervising the system piping. Loss of the supervisory air pressure in the system piping results in a trouble signal at the alarm panel. A prealarm of a possible fire allows time for alternate fire extinguishment prior to a sprinkler discharge. In the event the fire cannot otherwise be extinguished, the preaction sprinkler system will then perform as the primary fire protection system. They are designed for applications such as refrigerated areas that require maximum protection against inadvertent operation of the sprinkler system.
View Complete Details

Sprinkler Systems

A fire sprinkler system is an active fire protection measure, consisting of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected. Although historically only used in factories and large commercial buildings, home and small building systems are now available at a cost-effective price.
Sprinkler Systems offer 24-hour protection. In addition to wet sprinkler systems, Guardian works on foam, pre-action, and deluge systems. We also perform performance tests on fire pumps and backflow preventers.
Guardian Safety & Security LLC designs, supplies and installs Sprinkler Systems according to NFPA 13 standards and in full compliance with the Civil Defense requirements.
View Complete Details

Fire Pumps

A fire pump is a part of a fire sprinkler system's water supply and can be powered by electricity or diesel. The pump intake is either connected to the public underground water supply piping, or a static water source (e.g., tank, reservoir, lake). The pump provides water flow at a higher pressure to the sprinkler system risers and hose standpipes. A fire pump is tested and listed for its use specifically for fire service by a third-party testing and listing agency, such as UL or FM Global.
Fire Pumps are mostly a combination of Diesel, Electric and Jockey pumps and are needed for providing large volume of pressurized water to sprinkler systems and hose reels. Types of pumps used for fire service include: horizontal split case, vertical split case, vertical inline, vertical turbine, and end suction.
Guardian Safety & Security LLC evaluates the pump capacity requirements through hydraulic calculations, designs, supplies and installs fire pumps according to NFPA 20 standards and in full compliance with the Civil Defense requirements
View Complete Details

Fire Hose Reels

Fire hose reels are located to provide a reasonably accessible and controlled supply of water to combat a potential fire risk. The length of a fully extended fire hose is 36 meters with a diameter of 19mm (outside diameter). These appliances are designed to deliver, as a minimum, 0.33L of water per second. A control nozzle attached to the end of the hose enables the operator to control the direction and flow of water to the fire. All fire hose reels come with a unique ball valve shut-off device, a plastic or solid brass hose reel nozzle and mounting bracket.

View Complete Details

Foam System

Any Sprinkler systemWet, Dry, Deluge, or Preactioncan be adapted to include the injection of foam concentrate in order to combat high risks such as flammable fuels and alcohol. The primary components added to the sprinkler system riser include bladder tanks to hold the foam concentrate, concentrate control valves to isolate the sprinkler system from the concentrate until activation, and proportioners for mixing the appropriate amount of foam concentrate with the system supply water.

These systems have a water supply that is held back by a deluge valve which remains closed until the detection or release system opens the valve. When the valve is opened water floods through the system over the entire area that the system covers.

Guardian Safety & Security LLC supplies, installs and maintain Deluge Systems according to standards, and in full compliance with the Civil Defense requirements.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • GUARDIAN SAFETY & SECURITY L.L.C. (GUARDIAN SAFETY & SECURITY L.L.C.)
  • P.O. Box 234425 Dubai, United Arab Emirates, United Arab Emirates
  • Share us via

( ! ) Warning: Cannot modify header information - headers already sent by (output started at /htmlcachedir2/dynamic-html-pages/eitempfilen/uae/company/guardian-safety-security-l-l-c/other-products.htm:44) in /home/sgupta/exportersindia.com/htdocs/script-files/company-page/index.php on line 59
Call Stack
#TimeMemoryFunctionLocation
10.0008457896{main}( ).../index.php:0
20.02412024288include_once( '/home/sgupta/exportersindia.com/htdocs/script-files/country-vanity/country_index_page_common_script.php' ).../index.php:309
30.04512746680include_once( '/home/sgupta/exportersindia.com/htdocs/script-files/company-page/index.php' ).../country_index_page_common_script.php:282
40.05453687048header ( ).../index.php:59
ExportersIndia: 404 Error Found
404Oops! It seems this page is not available

We connect Buyers and Sellers

Tell us What you Need

Trending Categories

Find Suppliers by Region


View All Categories

Find Suppliers by Country

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice