Our Products
Our Complete range of products are Distributors Systems, Multiple Tank System, Dosing Tank, JMA Controller and Tanks Reverse Osmosis System Round.
Our distributors systems are designed for water treatment systems. They will fit pressure vessel diameter sizes for 7"-80". The hub & lateral system features threads connection which can assure you on safety in the operation. The unique slot design assure a uniform, vertical distributor of flow throughou the entire bed, without channeling.
Adopts advanced Reverse Osmosis membrane technology with 5 stages of purifiation to remove chlorie, minerals, heavy metals, pesticides, and organics
|
feature
1-connection
4040 end port
4040 side port
8040 side port(cellular board)
8040 side port(flat board)
8040 end port
working pressure: 150/300/450/600/800/1000 psi
2-length:1-7elements
3-color: white as standard, other color available as required
4-customized design as required
technical refference
1-product standard: jc692-1998
2-design working pressure: 150/300/450/600/800/1000 psi
3-working temperature: -7oc-49oc
4-permeability test: test water pressure 1.5 times standard working pressure
accessories of membrane housig are also available.
.Total Dissolved Solids(TDS) are the total weight of all solids(minerals, salts, or metals) that are dissolved in a given volume of water, express in milligrams per liter(mg/L), or in parts per million(ppm).
pH is a unit of measure which describes the degree of acidity or alkalinity of a solution. It is measured on a scale from 0 to 14.
The orP is an important water chemistry parameter, providing a measurement of the oxidizing and reducing capacity of water.
The disc filter is widely used as a pretreatment for HVAC systems in industrial and commercial areas such as desalination, food, textile, metallurgy, plastics, medicine, building materials, papermaking, industrial and commercial buildings, irrigation, wastewater treatment, sewage Renewable, municipal water supply, water plants, large power plants, chemical companies, and emergency areas such as filtering, the whole set of equipment related to the safe and effective operation.
1. Application of disc Filter in Membrane Pretreatment
1.1ultrafiltration / microfiltration pretreatment
The inner diameter of the vacuum fiber yarn was 0.8 mm and 0.3 mm
The role of disc filter: filter than the membrane pore size of solid particles, to avoid the vacuum membrane wire plug, protective film wire is not scratched.
1.2Reverse osmosis / Nano filtration pretreatment
When the water conditions are poor, such as river water, water, disc filter can be used for other pretreatment filtration equipment.
When the water conditions are good, such as tap water, deep well water, disc filter can be used to secure the filter before. In general, the role of disc filters in membrane pretreatment is to filter the equipment or to protect the follow-up equipment to reduce the follow-up equipment filtration load.
2.Application of disc Filter in Circulating Water Filtration
In industrial water, cooling water accounts for 70-80% of the total water consumption. Cooling water system to deal with large amounts of water, handling more difficult. But the running water temperature is low, so the water quality requirements lower than the boiler water.
Among them, the closed-cycle process requires cooling water is not exposed to the air; water loss is small, little change in salt content in water.Generally used for generators, internal combustion engines or have a special request for single heat transfer equipment. In the open cycle, the cooling water cooling tower, cooling water and air contact. Suspended matter in the water, ion content is constantly changing. Need to add cooling water, the need for sewage.
Disc filters can be used in the following areas
Pre-treatment of make-up water: coagulation, sedimentation, filtration, softening, desalting
Circulating water filtration treatment: full flow filtration, side filtration (circulating water volume 1-5%)
Sewage treatment: filtration, desalination reuse (to achieve zero discharge of sewage water)
3.Application of Disc Filter in Ion Exchange Pretreatment
Ion exchange is the use of ion exchange resin and water ions in the water to remove harmful ions in water treatment methods.
The disc filter in which can be used for pre-filtration, resin-based capture later, salt filtration system.
4.The Application of disc Filter in the Total System Water
With the rapid development of industry and agriculture, more serious pollution of water resources, water quality continues to deteriorate. The growth of suspended solids in water seriously affected industrial production.
Modern industrial production of water quality of water put forward higher requirements (high water). Sophisticated production of products, requiring almost no impurities of pure water. But there is no direct water directly into the nature of H2O equipment. The idea of hierarchical processing has become increasingly clear. Filtration is the most basic and simple treatment unit for water treatment, which is indispensable for water treatment.
5. Application of Disc Filter in Agricultural Irrigation
Sprinkler drip irrigation is known as the drip irrigation system in the heart, the water flow pore size is generally small, which requires irrigation water cannot contain the emitter blockage of dirt, so the irrigation water purification treatment is to ensure that sprinkler irrigation The key to normal operation of drip irrigation system.
6.The Application of disc Filter in Industrial Nozzle Protection
cdl/cdlf is a kind of vertical non-self priming multistage centrifugal pump, which is driven by a standard electric motor. The motor output shaft directly connects with the pump shaft through a coupling. The pressure-resistant cylinder and flow passage components are fixed between pump head and inlet & outlet section with stay bolts. The inlet and the outlet section are located at the pump bottom at the same plane. This kind of pump can be equipped with an intelligent protector to effectively prevent it from dry-running, out-of-phase and overload.
operation condition
thin, clean, non-flammable and non-explosive liquid containing no solid granules and fibers.
liquid temperature
normal temperature type:-15+70oc
hot water type: -15+120oc
ambient temperature: up to +40oc
altitude: up to 1000m
Technology: These series of activated carbon in granular form are made from fruitshell or coal, activated via high temperature water steam method, under the process of crushing, after treatment.
Characteristics: These series of activated carbon with large surface area, developed pore structure, high adsorption, high strength, well washable, easy regeneration function.
Using fields: Widely used in living industrial water treatment, environmental protection, vapor phase adsorption, solvent recovery, especially suitable in electric plants, petrifaction, refinery, food beverage, sugar, wine, electronic industry, drinking water, pisciculture, marine, industrial waste water, living waste water treatment etc. effectively adsorption dissociative chlorine, hydroxybenzene, sulfur, oil, colloid, pesticide hangover, other organic pollutant, oil precursors of THM from water, also applied for industrial tail gas purification, decarbolization, denitration, petroleum catalyse, gas separation, PSA, air drying, food keeping fresh, gas mask, removing dioxin, accelerant carrier, home decoration, car tail gas purification, nuclear electric power radioactivity pollute gas adsorption, distinct purification, filtering, recovery, refining function on industrial organic solvent such as benzene, toluene, formaldehyde, gasoline, diesel oil.
|
HY-230 |
|
Physical characteristics |
Raw material |
anthracite |
Mesh |
3.0mm |
|
Surface Area m2/g |
950-1050 |
|
Total Pore Volumecm3/g |
-0.86 |
|
Mediu Pore Volume cm3/g |
-0.40 |
|
Apparent Density g / cm3 |
0.5-0.68 |
|
LignitionoC |
420 |
|
chemical characteristics |
Moisture%< |
5 |
Hardness%> |
95 |
|
pH |
>7 |
|
Iodine number(mg/g) |
800-1050 |
|
Phenol adsoption(mg/g) |
140 |
|
CCl4 % |
50-70 |
|
Ash% < |
15 |
|
MB value(mg/g)> |
|
HXP bag filter system is a new filter system. It is character with high precision, big flow, easy installation and maintenance. So it can be widely used in the field of liquid treatment: foods, cosmetic, chemistry, medicine, textile, etc. it consists of housing, support basket, and the filter bag.
It can install all material, all precisions filter bag 1PCS.
The highest of working temperature is 45, the size of two holes in the lid of the filter is G1/4
If the thread of the pressure gauage is metric standard, should add an adaptor.
Product merits
1. UPVC material has good corrosion resistant
2. The unique seal system makes the filter more safety
3. It can prevent the bag plunged into the support basket, no inner leak
4. Good appearance and compact inner construct
5. High precision, the filter range can be from 0.5200un
6. High efficiency of filter: quick flow of liquid, big capacity of impurity
7. The price is more competitive
Horizontal multistage non-self-certificugai pump, attached with long shaft electric motor
Compact structure renders small size of pump; axial inlet radial outlet.
Curve conditions
Following condition are suitable for the performance curves shown above.
All curves are based on the measured values of 50Hz; constant motor speed 2900r/min, 60Hz; contant motor speed 3500r/min;
Curve tolerance in conformity with ISO9906Annex A.
Measurement is one with 20oC air-free water, kinematic viscosity of 1mm2/sec.
The operation of pump shall refer to the performance region described by the thickedned curve to prevent overheating due to small flow rate overload of motor duo to toolarge flow rate.
Operation condition
liuid temperature:
Normal temp:-15oC-70oC
Hot water:-15oC-115oC
Ambient temperature :up to 40oC
Max .operation pressure: 10bar
Max. inlet pressure is limited by max .Operation presure.
Diameter |
Model |
Installation |
Measure Range |
Screw Thread |
Case material |
Accuracy |
11/2" |
YTN-60 |
Bottom connection |
0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 |
G1/8" G1/4" 2G1/8" 2G1/4" 21/8" 21/4" M14X1.5 |
SS 304 |
2.5 |
MA stager controller functions:
Password setting
Calendar
Regeneration stage and regeneration time indication
JMA can be initiated manually or through remote control. Timer initiation and intervalinitiation are also
available.
Manual step by step initiation (only for system commissioning)
Reset function
Stages (1-8) and stage duration (5-9999 Sec) settings
System working stage indication (Service or regeneration stage indication)
Data protection after power cut: settings and data can be stored for 3 years.
Waterproof and rotproof enclosure
Stager working principle:
The stager may be manually operated or driven by an electricmotor that operated through an adjustable timer or flowmeterprogram. The stager functions by opening and closingits ports, singly or in combination, in a sequence thatfit the need of the system. The positions in thesequence correspond to the number of stager inthe process (See chart 1). The port that are opened allow the pressurized fluid to flow to and operate some diaphragm valves, while venting other valvesallowing them to return to their normal positions.The stagers can use either hydraulic or pneumatic control fluid. Continuous electrical power is not required to maintain the positions of the valves such as in a solenoid operated system. Greatly avoid the system breakdown because of power failure.All types of complex application can be controlled by stager controller system through correct design and combination of the stagers
Using Nylon as material, Nylon Melt Blown Filter Cartridge has high resistance to acids, alkalis and high temperature. The micron rate is controlled by adjusting the dimeter of Nylon fiber
HPCF cartridge filter is a filter system with high precision. It consists of the housing and cartridge elements, mainly used in pretreatment. It can be widely used in electronic industry, sewage treatment, beverage, foods, pure water treatment, also it can acts as home water purification equipment.
In 2005, it has got the unique model patent, which is issued by the state intellectual property office
of the P.R.C. the patent NO is: ZL 2005 20101822.3.in 2006, it has applied for the patent of invention.
The application NO is 200510049495.X.It has achieved 0-0.6MPa 100, 000 times recycle fatigue test successfully.
YTN-Series liqud filled pressure gauage fill damping fluid(sllicone oil, glycerol)in the gauage and other measures to ensure that it has excellent function of impact resistance and aseiamatic Soit is safe and reliable.
With stable performance and long usefull-life it is apply to mechnical, Chemical, metallury, mine.Electrical, measure the pressure of medium isnon corrosive for copper and alday.
If measure the pressure of high corrosive medium, all meterial of pressure gauge must be stainless stell.
Feature
1-Connection
4040 End port
4040 Side port
8040 Side port(Cellular board)
8040 Side port(Flat board)
8040 End port
Working Pressure: 150/300/450/600/800/1000 psi
2-Length:1-7elements
3-Color: White as standard, other color available as required
4-Customized design as required
Technical Refference
1-Product Standard: JC692-1998
2-Design working pressure: 150/300/450/600/800/1000 psi
3-Working Temperature: -7oC-49oC
4-Permeability test: Test water pressure 1.5 times standard working pressure
Accessories of membrane housig are also available.
domestic trade name: pt3000a export trade name: pt3000a
chemical type: water soluble polymer
product use: reverse osmosis membrane pretreatment/antiscalant
information on hazardous ingredients
non-hazardous ingredients
cas #: 52255-49-9
hazards identification
health hazards:
primary route of exposure: skin contact, eye contact, and inhalation
inhalation: exposure to spray may cause irritation to the mucous membranes and respiratory system.
skin contact: exposure to skin can cause irritation. Eye contact: material can cause irritation to eyes. Ingestion: material is not harmful if accidentally ingested.
medical conditions aggravated by exposure: none known
tlv (threshold limit value): n/a, no danger exists.
first aid measures
first aid for ingestion: if swallowed give 2 glasses of water to drink. Seek medical attention immediately. Never give anything by mouth to an unconscious person.
first aid inhalation: remove to fresh air. In case of shortness of breath call a physician immediately.
first aid eye contact: immediately flush eyes with plenty of water for at least 15 minutes. Seek medical attention immediately.
first aid skin contact: wash exposed area with soap and water immediately. Remove and wash contaminated clothing.
fire fighting measures
auto ignition temperature: n/a
flammable limits: lel (lower explosive limits) not applicable flammable limits: uel (upper explosive limits) not applicable flash point: not applicable
fire fighting media: use media appropriate to primary cause of fire. Special fire fighting procedures: none known
fire/explosion hazards: none known
special procedures: use water spray to cool containers exposed to fire. Minimize exposure. Do not breathe fumes. Contain run-off.
accidental release measures
spill/leak clean-up procedures: if possible neutralize with alkaline soap.
land spill: wearing recommended protective clothing and equipment, dike spill with soil, sand, or compatible commercial absorbent. Remove remaining liquid with a pump, vacuum truck, or absorb liquid in sand or commercial absorbent. Place waste in approved containers for disposal. Dispose waste according to local regulations.
water spill: wear protective clothing and equipment. Stop flow. Dike contaminated water and remove for disposal and/or treatment. Notify proper authorities and all downstream users if possible. Dispose of with solid waste according to federal, state, and local regulations.**caution: floor will be slippery.
personal protection: wear a niosh approved (or equivalent) respirator (with an organic/acid gas cartridge and a dust filter) during spill clean-up and deactivation of the material. Protective clothing including chemical splash goggles, latex, nitrile, or buytl rubber full-length gloves, rubber apron made of nitrile or buytl rubber, and rubber overshoes must be worn during spill clean-ups and deactivation of material. If this material comes into contact with the skin during clean-up operations, immediately remove all contaminated clothing and wash exposed skin areas with soap and water. See section 4, first aid measures, for further information.
handling and storage
precautionary measures:
avoid breathing spray. See section 8, exposure control/personal protection, prior to handling.
storage conditions:
the maximum storage temperature for this material is 55c/131f. The minimum storage temperature for this material is 0c/32f. Store in a well-ventilated area. Do not store this
material in containers made of steel.
exposure control/personal protection
ventilation: use local exhaust ventilation at the point of dust or mist evolution
respiratory protection: dust masks where spraying cannot be avoided.
eye protection: safety glasses, splash goggles, and/or face shields (ansi z87.1 or approved equivalent).
skin protection: use latex, neoprene, or rubber gloves, boots, and apron. Remove gloves after use;
wash hands with soap and water.
personal hygiene: observe ordinary measures of personal hygiene.
stability and reactivity
stability: this material is considered stable under specific conditions of storage, shipment, and/or use. See section 7, handling and storage, for specific conditions.
hazardous polymerization: will not occur
condition to avoid: none known
incompatible materials: strong oxidizing or reducing agents
hazardous decomposition products: none known
toxicological information
acute toxicity:
mutagenicity: ames salmonella mutagenicity testing exhibits no evidence of mutagen presence.
oral toxicity: rat ld50>100, 000 mg/kg
dermal toxicity: not absorbed topically
inhalation toxicity: none known
skin irritation: rabbit; no irritation observed
sensitizer: no human repeat insult patch test, not a sensitizer
ecological information
environmental toxicity:
acute fish 96 hr lc50, flathead minnow: 750 mg/l, noec/loec 500/1000
acute daphnia 48 hr ec50: 743 mg/l, noec/loec 500/1000
acute purple sea urchin 40min. Ic25 mg/l: >10, noec/loec 10/>10
disposal
incinerate liquid and contaminated solids in accordance with local regulations and permits.
transport information:
domestic date
dot shipping name: not regulated dot hazard class: not regulated hazardous ingredients: none
export data
export shipping name: not regulated export hazard class: not regulated hazardous ingredients: none
un number: none
regulatory information
sara section 313 notification (40cfr 372)
this product does not contain toxic chemicals subject to the reporting requirements of
section 313 of title iii of the superfund amendments and reauthorization act of 1986 and 40
cfr part 372.
all components of this product are in compliance with the inventory listing requirements of the u.s toxic substance control act (tsca) chemical substance inventory.
other information
hmis hazard codes health/flammability/reactivity; 0, 0, 0
nfpa hazard codes - health/flammability/reactivity; 0, 0, 0
made in u.s.a.
Description: Resin Performance:
Matrix structure ………………………………….. Copolymerized styrene-DVB gel-type resin
Function group …………………………………. -HSO3-
Appearance …………………………………..light brown yellow transparent spherical particles
Ionic form as shipped …………………………………Na+ Type
Total exchange capacity in quality ………………≥4.5mmol/g(Dry)( Na+ Type)
Total exchange capacity in volume ……………..≥1.9mmol/mL(Dry)( Na+ Type)
Moisture holding capacity ………………………….45~55%( Na+ Type)
Specific gravity …………………………………..1.25~1.29g/mL(Na+ Type)
Shipping weight ……………………………………….. 0.77~0.87g/mL(Na+ Type)
Particle size ………………………………. ……………≥0.45~1.25mm ≥95%
<0.45mm <1%
Harmonic mean size …………………………………..≥0.50mm
Uniformity coefficient ……………………………………≤1.6
After a ball mill rate ……………………………………… ≥90%
Maximum reversible swelling ………………………. Na+~H-:10%
Suggest Operation Condition
Maximum operation temperature ……………….120℃
Minimum bed depth…………………………………....800mm
Service flow rate ………………………………………….≥90%
The largest operation rate …………………………..5~25V*/H
Regenerant ………………………………………………… NaCl HCl H2SO4
Level (% of ionic load)………………………………….80-220g/L 50-150g/L 80-240g/l
Concentration (%)………………………………………..5-10% 5-8% 0.7-6%
Flow rate …………………………………………………….2-8BV*/H 2-5BV*/H 2-20BV*/H
Minimum contact time ……………………………….30min
Slow rinse……………………………………………………2BV*(regenerant flow rate)