Our Products
Industrial Blowers, Coolers & Fans
2 Products availableDmc Busbar Support
2 Products availableCircuit Breaker
2 Products availablePower Contactors
2 Products availableAutomotive Lights
2 Products availableThermostats
1 Products availableInstrumentation Equipment
1 Products availableOur Complete range of products are Residual Current Protection Module, Semiconductor Heater and Power Supply.
4 Position Ammeter Selector Switch
.
7 Position Voltmeter Selector Switch
Buzzer CBZ-10.Available in 12V, 24V, 110V and 220V.
Buzzer CBZ-20 .Available in 12V, 24V, 110V and 220V
Buzzer CBZ-30.Available in 12V, 24V, 110V and 220V
rame(A):1600N, 4000H1, 4000H2, 6300L In (A):630 6300
Frame(A):1600N, 4000H1, 4000H2, 6300L In (A):630 6300
Basic Technical Data
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A
Standard:IEC 61008-1RCCB Type: AC, ASensitivity: 30, 100, 300mA
HDB6VR Residual current operated circuit breakers combine the following functions:
Standard: I EC 60947-3HDB6IS switch disconnectors combine the following Function:
Standard: I EC 60947-4-1
Product Name | Rated Current | Main Current | Coil Voltage | Coil Frequency |
HJX2 | 09 | 04 | 7 | |
09:9A 12:12A95:95A | 04:4NO+0NC 08:2NO+2NC | B:24V X;440V | 7:50/60Hz |
HLD 11 Series of indicator light provide:Pilot signal, anticipating signalsEmergency signals and other instructions incidents signal use
Technical Data
Rated Voltage(V) | AC/DCt | AC |
Rated Current(MA) | ||
Working Life (H)Brightness of the Iight(cd/m2) | 3000240 | |
Power Frequency withstand voltage)> | 2500 VAC 1min | |
Before board protect degree | IP65 | >> |
Standard: IEC 60044-1Primary current: 100A-5000ASecondary approval: 5A, 1AMaximum voltage: 0.66kVClass: 0.5, 1.0, 3.0Short time thermal current: lth=100lhRated security coefficient: FS
HLD 11 Series of indicator light provide:Pilot signal, anticipating signalsEmergency signals and other instructions incidents signal use
Technical Data
Standard | I EC 60051 |
Dielectric strength test | Frequency 50/60Hz Voltage 2000V, Duration 1 m |
Impact test | Max acceleration 147m/s2 |
Response time | 4s |
Angular Deflection | 90 |
temp | -25 -+40 |
Humidity | (25%-80%)RH |
Evvironment | No mildew, insects, salt mist, dew in the air, few sands and dusts are permitted. |
Installation | Shall be installed vertically |
Standard: IEC60947-1.IEC 60947-4-1
Product Name | Frame Current | Setting Current | Installation Type |
HDR6 | 18 | 11 | M |
18:18A 630:630A | P15: 0.1-0.15 630:460-630AP means decimal point | Default: NoneIndependent Installation |
Standard: I EC 60947-1, IEC 60947-2, I EC 60947-4-1
Product Name | Frame Current | Setting Current |
HDP6 | 32 | P16 |
32:32A | P16:0.1-0. 16A 32:24-32AP means decimal point |
Used to implement the conversion of intermediate control signals and low-power output, In the field of industrial control, used in conjunction with contactors, relays, circuit breakers, etc.
Technical Information
Standard | IEC 61095 | |
Ambient Temperature | -5C-40C | |
Rated Voltage Ue | 230V AC | |
Rated Insulation Voltage Ui | 500V AC | |
Operation Time | >30000 times | |
Coil Volatge(Us) | 220/23V AC | |
Type | AC-7a | AC-7B |
Rated Current (le) | 20A/25A/32A/40A/63A | 7A/8.5A/12/A/15A/25A |
Rated Power | 4kW/5.4kW/6.5kW/8.4KW/13KW | 1.2kW/1.5kW/1.9kW 2.4W/3.8kW |
Operation Frequency | 1200times/h | 30time/h |
Making & Breaking Capacity | 1.5le | 8le |
The state-of-the-art regulators of the MAX Series have been designed to offer simple and efficient regulation features. The whole range of computer regulators is based on CIRCUTOR's FCP system (Fast Computerized Program), offering a set of unique performance features. Its main features are as follows:
Current Measuring Tranformers are specifically designed for their use in those places with a limited free space for their installation such as close to circut-breakers and any position with a minimum seperation space between the bus bars,
Display | Mechanism | IDn A | Delay(s) | Type | Code |
LED | Electronic | 0, 03.5 | 0, 02.5 | RN-R | P12132 |
Electrical features
Auxiliary power supply | 230 V a.c. ( 20%) 50 . 60 Hz |
Output contacts | 250Va.c. 6 A |
Operating temperature | -10C/+50C |
Mechanical features
Mounting | DIN rail |
Dimensions | 2 modules |
Weight | 163 g |
Protection grade Terminals | IP 20, Front side: IP 41 |
Standards | IEC 61008-1, IEC 755, IEC 255-5 |
eight | Useful diameter 0(mm) | Type | Code |
148 g | 35 0 | WN-35 | P10211 |
281 g | 70 0 | WN-70 | P10212 |
433 g | 105 0 | WN-105 | P10213 |
574 g | 140 0 | WN-140 | P10214 |
1.201g | 2100 | WN-210 | P10215 |
KTO 011:Thermostat (normally closed); contact breaker for regulating heaters.
KTS 011:Thermostat (normally open); contact maker for regulating of filter fans and heat exchangers or for switching signal devised when temperature limit has been exceeded.
Features
The Electromechanica thermostat MFR 012 is designed to control enclosure heaters so that the dew point is raised when a critical relative humidity of 65% is exceeded. In this way condensation and corrosion is effectively prevented,
Features
Roof filter fans and roof exhaust filters are used in enclosures from which warm air must be diverted due to increased heat development. The ready-to-connect and low-noise roof filter fan is used to expel warm air from within the enclosure. Alternatively, the roof exhaust filter provides passive ventilation. The RFP 018 series comes in two versions, one utilizes four small axial fans, improving reliability and maintaining continous operations even if one of the fans should fail, the second uses a larger single high capacity fan.
Features
The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured.
Features
Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating..
Features
3-pole, 60mm system, combination base for 5 and 10mm thick busbars and double-t-section latching mechanism when sliding onto busbar opened box terminal 1.5-25mm2
Features
Height mm | Insert | PowermatCodeNo | Rt Diamm | Rb Diamm | Hb Diamm | Nominal Voltage( AC/DC) |
25 | M6 | C625 (M6) | 19 | 25 | 10 | 400/500 |
30 | M6 | C630 (M6) | 25 | 30 | 10 | 600/750 |
30 | M8 | C830 (M8) | 25 | 30 | 10 | 600/750 |
40 | M8 | C840 (M8) | 33 | 40 | 15 | 1000/1200 |
40 | M10 | C1040(M10) | 33 | 40 | 15 | 1000/1200 |
50 | M10 | C1050(M10) | 40 | 50 | 20 | 1200/1500 |
50 | M12 | C1250(M12) | 40 | 50 | 20 | 1200/1500 |
60 | M10 | C1060(M10) | 42 | 50 | 20 | 1500/1800 |
60 | M12 | C1260(M12) | 42 | 50 | 20 | 1500/1800 |
70 | M10 | C1070(M10) | 41 | 50 | 25 | 2000/2400 |
70 | M12 | C1270(M12) | 41 | 50 | 25 | 2000/2400 |
Properties | Unit | Value |
Density | g/cm | 1.35 |
Tensile strength | N/mm | 180 |
Elongation at break | % | 3 |
Tensile modulus of elasticity | N/mm | 11500 |
Impact strength charpy +23c | KJ/m | > 70 |
Impact strength charpy -40c | KJ/m | > 70 |
Other datas
Melting temperature | C | 214 |
Max operating temp permanent | C | 160 |
Tensile strength | C | 200 |
Elongation at break | C | 215 |
Tensile modulus of elasticity | % | 1.9-2.4 |
Electrical data
Surface resistance | Ohm | 10 |
Di-electric strength | Ohmcm | 1015 |
Di-electric loss factor tan | --- | 0.024 |
Creepage factor | --- | 450 |
Cable Gland BW & CWAvailable Sizes20S, 20L TO 75S, 75L
Copper LugsAvailable Sizes2.5Sqmm x M5 to 630Sqmm x 21D
Copper BushAvailable sizes6x15, 6x20, 8x10, 8x15, 8x20