Post Your Requirement Menu

Welcome User

Other Products / Services

Our product range comtains a wide range of Round Enamelled Copper Wires, rf feeder cable, din connectors, RF JUMPER RIGHT ANGLED and Automotive Cables

Round Enamelled Copper Wires

Round Enamelled Copper Wires     SCTL is one of the leading enamelled copper wire producer in INDIA. Our company is using the state of art machinery for enamelled copper wire production. We can produce enamelled copper wire according to national and international standards such as IEC, & NEMA. The aim of our company is to produce high quality enamelled copper wire. Quality control team strictly applies quality control test at every step of production. SCTL is always the disposal of its client to provide technical assistance and share its vas experience with them.

  • Type of Enamelled Wire Self Self Self Self Self  Self  Self 
    solderable solderable solderable solderable solderable/ solderable/ solderable/
            & bondable Self bonding Self bonding
    SPECIFICATION IS : 13730-19/ IS : 13730-21/ IS : 13730-20/ IS : 13730-23/ IS : 13730-2/ IS : 13730-35/ IS : 13730-36/
    IEC-60317-19/ IEC-60317-21 IEC-60317-20/ IEC-60317-23 IEC-60317-2 IEC-60317-35 IEC-60317-36
    NEMA NEMA NEMA     JIS C 3202-SBUEW JIS C 3202-SBUEW
    MW-28C MW-80C MW-79C        
    THERMAL CLASS 130 (B) 155 (F) 155 (F) 180 (H) 130 (B) 155 (F) 180 (H)
    Chemical Base of Base Coat Polyurethane Polyurethane Polyurethane Polyesterimide Polyurethane Polyurethane Polyesterimide
    Chemical Base of Top Coat Nylon Nylon Not applicable Not applicable Polyvinyl Polyvinyl Polyvinyl
    butyral/ Polyamide butyral/ Polyamide butyral/ Polyamide
    Range of Wire (Diameter) 1.42 -0.20 mm 1.42 -0.20 mm 0.80-0.20 mm 1.42 -0.20 mm 1.42 -0.20 mm 0.80-0.20 mm 1.42 -0.20 mm
    UL Listed File No. : None File No. : None File No. : None File No. : None File No. : None File No. : None File No. : None
View Complete Details

rf feeder cable

  • Electrical Characteristics Impedance
  • 50±1 Ω  
  • Relative Velocity of propagation 82%
  • Capacitance (1KHz) 78 pF/m
  • Maximum operating frequency 20.4 GHz
  • Cut-of frequency 25 GHz
  • Peak power 90 KW
  • Inner conductor  DC-Resistance ≤10.5 Ω/Km
  • Outer conductor  DC-Resistance ≤6.5 Ω/Km
  • Inductance 0.195 µH/m
  • DC breakdown voltage 1600 V
  • Jacket spark voltage (rms) 5000 V
  • Return loss (800~1000) MHz ≥26 dB
  • VSWR ≤ 1.1 Return loss (1700~2200) MHz
  • ≥24 dB VSWR ≤ 1.13
  • Insulation resistance ≥10 GΩKm
  •   Passive intermodulation

  • Mechanical Characteristics
    Inner Conductor Copper clad aluminium wire 1.88 mm
    Dia over Dielectric Foamed PE 4.6 mm
    Dia over outer conductor Corrugated copper tube 6.5 mm
    Diameter over outer jacket PE 7.7 mm
    Cable weight PE 83 Kg/Km
    Tensile strength   350 N
    Bending moment   1.5 Nm
    Flat plate crush strength   8 N/mm
    Min.bending radius single   12.5 mm
    Min.bending radius repeated   25 mm
    No.of bends, minimum(typical)   20(50)
    Recommended hanger spacing   0.6 m
    Installation temperature   -40°C~+60°C
    Operating temperature   -55°C~+85°C
    Storage temperature   -70°C~+85°C

     

    Frequency(MHz) 100 450 800 900 1000 1800 1900 2100 2200 2300 2500 2700 3000
    Attenuation typical (dB/100m) 5.6 12.3 16.8 17.9 19 26.3 27.2 28.7 29.5 30.2 31.7 33.2 35.2
    Average power (KW) 1.13 0.52 0.39 0.37 0.35 0.25 0.24 0.233 0.23 0.223 0.21 0.20 0.19

     

View Complete Details

din connectors

  • ELECTRICAL DATA Impedance
  • 50 Ω Frequency
  • DC-8.3GHz Insertion Loss
  • ≤0.05dB Center Contact Resistance
  • ≤0.4mΩ Outer Contact Resistance
  • ≤1.5mΩ Insultation resistance
  • ≥10000MΩ Withstanding Voltage AC (v/min)
  • ≥4000V Power Handling
  • 1800W@1GHz 800W@4GHz RF Leakage
  • 128dB@1GHz Intermodulation (3rd order)
  • ≤-160dBc@2x20W Retention for all female Connectors
  • 6~18N Environmental Data
  • Temperature Range -40~+850C
  • Relative Moisture 90%~95%, Temprature: 40±20C
  • Water Proof IP67
  • Rapid Change of Temperature DIN EN 122190, Clause 4.6.7
  • Corrosion DIN EN 122190, Clause 4.6.10
  • Vibration DIN EN 122190, Clause 4.6.3
  • Damp Heat DIN EN 122190, Clause 4.6.6
  • Climate Test DIN EN 122190, Clause 4.6.5(55/155/56)

  • Model Type SA158 CDM SA158 CDF SA114 CDM SA114 CDF SA 078 CDM SA 078 CDF SA 012 CDM SA 012 CDF
    Connector Size 1 5/8" Male 1 5/8" Female 1 1/4" Male 1 1/4" Female 7/8' Male 7/8' Female 1/2" Male 1/2" Female
    VSWR ≤1.1 (0~2.2GHz) ≤1.1 (0~2.2GHz) ≤1.1 (0~2.2GHz) ≤1.1 (0~2.2GHz) ≤1.1 (0~3GHz) ≤1.1 (0~3GHz) ≤1.1 (0~3GHz) ≤1.1 (0~3GHz)
    Suitable Cables SHILPI 1 5/8" SHILPI 1 5/8" SHILPI 1 1/4" SHILP 1 1/4" SHILPI 7/8" SHILPI 7/8" SHILPI 1/2" SHILPI 1/2"
    Packing 1Pc in box 1Pc in box 1Pc in box 1Pc in box 1Pc in box 1Pc in box 1Pc in box 1Pc in box

     

    Material Plating
    Connector Part Material Plating
    Shell Brass Alloy
    Center Contact Brass Silver
    Back Nut Brass Alloy
    Clamp Brass Alloy
    Sealing Silicone rubber  
    Insulator PTFE (orTPX)

     

View Complete Details

RF JUMPER RIGHT ANGLED

  • Min. bending radius, single 25 mm
  • Min. bending radius, repeated 35 mm
  • ELECTRICAL DATA Impedance
  • 50±1 Ω Frequency
  • DC - 2.2 GHz Relative Velocity of Propagation
  • 81% Return Loss
  • ≤-26 dB 800-1000 MHz ≤-24dB 1700 - 2200 MHz Insertion Loss
  • ≤ 0.10 dB/m (cable) + 0.1 dB (2 connectors) 900 MHz ≤ 0.15 dB/m (cable) + 0.1 dB (2 connectors) 1800 MHz ≤ 0.16 dB/m (cable) + 0.1 dB (2 connectors) 2200 MHz Peak Power Rating
  • 16 KW DC breakdown Voltage
  • 2500 V Power Handling (at 20°C, Sea Level,VSWR 1.0)
  • 800 W @ 1 GHz 500 W @ 2 GHz Insulation Resistance
  • ≥ 10 GΩ-Km Intermodulation (3rd order)
  • ≤ -117 dBm Intermodulation Test Method
  • Two +43 dBm Carriers Environmental Data
  • Operation temperature -45°C ~ 85°C
  • Vibration MIL-STD-202,Meth.204,Cond.B
  • Shock MIL-STD-202,Meth.213,Cond.B
  • Corrosion MIL-STD-202,Meth.101
  • Degree of Protection (mated pair) IP67
  • RoHS Compliant

Standard Conditions For attenuation, VSWR 1.0 , ambient temperature 20 °C For Average Power, VSWR 1.0 , ambient temperature 40 °C Inner conductor temperature 100 °C, no solar loading

  • Jumper Type DIN(M)-DIN(M)RA DIN(F)-DIN(M)RA N(M)-DIN(M)RA
    Model SA12JDMDMR SA12JDFDMR SA12JNMDMR

     

    Mechanical Data
    Cable Inner conductor
    Dielectric
    Outer conductor
    Jacket option
    Copper clad aluminium wire
    Highly foamed polyethylene
    Spiral corrugated
    copper tube PE/FRNC
    Connector Center contact
    Insulator
    Outer contact
    Gasket
    Brass/Silver-plated
    PTFE
    Brass/Alloy-Plated
    Silicone Rubber

     













View Complete Details

Automotive Cables

AUTOMOTIVE CABLES Automotive cables are manufactured to reference standards BS: 6862, JIS 3406 and IS: 2465 with bright annealed high conductive electrolytic copper conductor conforming to the requirements of IS:8130/BS6360 and insulated with specially designed dielectric grade PVC compound which is impervious to water, oil, petrol, acid and greases. We specialize in a variety Automotive Cables, ranging from light duty throttle cables for outdoor power equipments to heavy duty brake & transmission cables for trucks and buses.  

View Complete Details

Pvc Insulated Battery Cables

PVC INSULATED BATTERY CABLES   Battery cables are used in Original Equipment by India's leading vehicle manufacturers. Manufactured from electrolytic grade, bright annealed, bunched, bare copper conductors, these cables are insulated on state-of-the-art extruders with a special grade PVC compound that is formulated and manufactured in-house. This PVC is impervious to water, petrol, diesel, acids, engine & lubricating oils and grease. It is ideally suited for extreme weather conditions. These cables undergo stringent quality checks during manufacturing process and at the final stage. They are available in red and black colours in 25-metre and 100-metre coils / drums. These cables are also used in other applications where batteries are used, e.g. telecommunication, power, computers, etc. where the D.C. voltage does not exceed 100 volts. These cables are long-lasting and ensure proper distribution of power in the vehicle.

  • Nominal Area sq.mm. Number / Dia. of strands (Nom.) mm. Resistance at 20°C (Max.) ohms / km Radial thickness of insulation (Nom.) mm. Overall diameter (Approx.) mm.
    10 140/.3 1.910 1.0 6.30
    16 126/.4 1.210 1.0 7.25
    25 196/.4 0.780 1.2 8.80
    35 276/.4 0.554 1.2 10.35
    50 396/.4 0.386 1.4 12.25
    70 360/.5 0.272 1.4 13.90
    95 475/.5 0.206 1.6 15.85
    120 608/.5 0.161 1.6 17.75
    150 750/.5 0.129 1.8 18.85
    185* 925/.5 0.106 2.0 22.00
    240* 1221/.5 0.0801 2.2 25.00
    PVC Insulated HIGH TENSION CABLES (IGNITION CABLES) in Black colour
    1.2* 17/.3 15.36 2.75 7.10
    1.3* 19/.3 14.01 2.75 7.10
View Complete Details

Flame Retardant Low Smoke (FRLS) Cables

  • Rated Voltage 0.6/1 kV AC
  • Rated DC Voltage 1.5 kV
  • Maximum Permitted DC Voltage 1.8 kV (conductor/ conductor, non earthed system, circuit not under load)
  • Maximum Permitted AC Voltage 0.7/1.2 kV
  • Working Voltage DC 1000 V
  • Insulation Resistance 1000 M-km
  • Spark Test 6000 Vac (8400 Vdc)
  • Voltage Withstand 6500 V as per EN50395 for 5 min
  • Ampacity According to requirements for cables for PV systems Construction Characteristics

Solar Cables are designed to meet the growing needs of the solar industry. Our solar cables is just the beginning of our plans to develop and launch green technology in wires & cables. Solar Cables are flexible and are resistant to abrasion & moisture. Regardless of your panel-to-grid needs, we have the cables to meet your requirements. Applications These cables are designed for connecting photovoltaic power supply systems. These cables can be used indoor & outdoor for flexible and fixed installations with high mechanical strength in extreme weather conditions. Standards 2 Pfg 1169/08.2007. Maximum Temperature at Conductor: 120°C (20000h) Short Circuit Temperature: 200°C (at conductor max. 5sec) Thermal Endurance Test: According to EN 60216-2 (temperature index +120°C) High Temperature Pressure: Test according to EN 60811-3-1 Damp – Heat Test: According to EN 60068- 2-78 1000 hrs. at 90°C with 85% humidity Mechanical Characteristics Minimum Bending Radius: 5 x OD (fixed), 15 x OD (occasional flexing) Dynamic Penetration: According to requirement of Cables for PV systems 2 Pfg 1169/08.2007 Annex F Notch Propagation: According to 2 Pfg 1169/08.2007 Annex G Tensile Strength: 6.5 N/mm2 for insulation and 8 N/mm2 for sheathing – according to EN60811 Elongation of Insulation and sheathing: 125% – according to EN60811 Anticipated Period of Use: 25 years Shrinkage: 2% at 120°C according to EN 60811-1-3 EU Directives The cables are RoHS (Restriction of certain Hazardous Substances) compaliant as per EU Directives 2002/95/EC Chemical Characteristics Mineral Oil Resistance: according to EN 60811-2-1 Ozone Resistance: according to EN 50396 part 8.1.3 Method B Weathering-UV Resistance: according to HD 605/A1 or DIN 53367 cables confirm to TUV specificationst. TYPE 2 DC Solar Cables are Single core Copper cables each for +ve and –ve. They are insulated with HR 105°C PVC compound and and sheathed with UV stabilized HR 105°C PVC compound. TYPE 3 DC Solar Cables are Single core Copper cables each for +ve and –ve. They are insulated with XLPE compound and and sheathed with UV stabilized PVC ST2 compound. B. Array Junction Box to Main Junction Box and Main Junction Box to Inverter These Solar DC cables which are not exposed to sunlight and are always routed through PVC Pipes which are laid underground. Choice of cables can be done from any one of the options given. Generally Option 3 is chosen for this route. Electrolytic Multi Stranded tinned copper conductor flexible as per IEC 60228 Class 5. Insulation Crosslinked Halogen Free & Flame Retardant Sheath Crosslinked Halogen Free & Flame Retardant Sheath in Black/Blue/Red Colour Thermal Characteristics Ambient Temperature: -40°C ~ +90°C Ammonia resistant : 30 days in saturated ammonia atmosphere (internal testing) Very good resistance to oil and chemicals High wear and robust, abrasion resistant Acid & Alkaline Resistance: According to EN 60811-2-1 (Oxal acid and sodium hydroxide) Fire Performance Flame retardant according to IEC 60332-1-2 Low smoke emission Halogen free according to EN 50267-2-1/- 2, IEC 60754-2 Acid gas emission not more than 0.5% as per IEC 60754-1 pH minimum 4.3 as per IEC 60754-2 conductivity maximum 10 as per IEC 60754-2 Toxicity according to EN 50305, ITC- index Specifications As per TÜV Rheinland specification: 2 Pfg 1169/08.2007. Solar Cables used in Solar Farm installations are mainly categorized as given below: A. PV module to PV module and PV modules to Array Junction Box These cables though not exposed to direct sunlight are throughout the day time exposed to diffused/ indirect sunlight and atmospheric temperatures in open air. TYPE 1 DC Solar Cables are Single core Copper cables each for +ve and –ve. They are insulated and sheathed with Cross Linkable LSOH which has UV as well as Ozone protection properties. These C. Inverter to Transformer Primary The Three Phase AC output from the Inverters is connected to the Transformer Primary through Underground Armoured Cables. These cables are Copper or Aluminium XLPE insulated, GI armoured, UV stabilised PVC ST2. D. Transformer Secondary to RMU/Switchyard The Three Phase AC output from the Tranformer Secondary is connected to the RMU/Switchyard through Armoured Cables. These cables are Copper or Aluminium XLPE insulated, GI armoured, UV stabilised PVC ST2. E. RMU to Switchyard Three Phase AC connection from the RMU is connected to the Switchyard through Armoured Cables. These cables are Copper or Aluminium XLPE insulated, GI armoured, UV stabilised PVC ST2.

  • Solar DC Cables from PV Module to Array Juntion Box (as per TUV Specifications-2 Pfg 1169/08.2007)
    Single Core Size in Sq.mm Max. Conductor Diameter in mm XL-LSOH Insulation Thickness-Nominal in mm XL-LSOH Sheathing Thickness-Nominal in mm Overall Dia. Nominal in mm
    1.5 0.26 0.7 0.9 5.0 +/-0.5
    2.5 0.26 0.7 0.9 5.5 +/-0.5
    4 0.31 0.7 0.9 6.0 +/-0.5
    6 0.31 0.7 0.9 6.5 +/-0.5
    Solar DC Cables from Array Junction Box to Main Juntion Box & MJB to Inverter
    (as per TUV Specifications-2 Pfg 1169/08.2007)
    10 0.41 0.7 0.9 7.5 +/-0.5
    16 0.41 0.7 0.9 8.5 +/-0.5
    25 0.41 0.9 1 10.5 +/-0.7
    35 0.41 0.9 1.1 12.0 +/-0.7
    50 0.41 1 1.2 14.0 +/-0.7
    70 0.51 1.1 1.3 16.0 +/-1.0
    95 0.51 1.1 1.5 18.5 +/-1.0
    120 0.51 1.2 1.6 20.0 +/-1.0
    150 0.51 1.4 1.7 22.5 +/-1.0
    185 0.51 1.6 1.9 25.0 +/-1.0
    240 0.51 1.7 2.1 28.0 +/-1.0
View Complete Details

TELEPHONE & SWITCHBOARD CABLES

SHILPI twisted paired cables are best suited for telephone and switchboard cabling applications. the conductor is made of solid annealed, high conductivity bare copper. The conductor is insulated with special grade high-density polyethylene with different colours. The insulated cores are twisted with uniform lay to form pairs and are bunched together in such a manner so as to minimise cross talk. In 50 and 100 pair cables the units of 10 and 20 pairs respectively are identified with colour binders and stranded to form the laid up cable. The laid up cable is further jacketed with a grey colour fire retardant (FR) PVC specially formulated and manufactured in-house, with high oxygen and temperature index. The cables can be used for switchboard and internal telephone wiring in high-rise buildings, offices, factories, hotels, residential complexes, etc. They generally conform to ITD specifications G/ WIR-06/02. May 94. Stringent quality control at every stage, from raw material through manufacturing, upto the finished product, guarantees high quality. Salient Feature : ⌉ LowAttenuation ⌉ LowCrosstalk ⌉ FireRetardant Jacket

  • Construction Parameters 1 Pair 2 Pairs 3 Pairs 4 Pairs 5 Pairs 10 Pairs 20 Pairs 25 Pairs 50 Pairs 100 Pairs
    Conductor (Solid annealed bare copper) 0.4 mm diameter (nom.) & 0.5 mm diameter (Nom.)
    Insulation Material (0.4 & 0.5 mm dia.) High density polyethylene
    Insulation Thickness 0.4 mm dia (Average) 0.5 mm dia 0.17 mm 0.20 mm
    Diameter of Insulated 0.4 mm dia Conductor (Maximum) 0.5 mm dia 0.74 mm 0.92 mm
    Rip cord (0.4 & 0.5 mm dia.) Nylon

     

    Electrical Parameters 0.4 mm dia 0.5 mm dia
    Conductor Resistance (max.) ohms/km at 20 143 92.2
    Mutual Capacitance (max.) nf/km 50 50
    Insulation Resistance in Air (min.) M-ohms/km 10,000 10,000
    Capacitance Unbalance Pair to Pair (max.) pF/km 250 250

     

View Complete Details

Telephone Cables

Telephone cables is a pair of copper wires runs from a box at the road to a box (often called an entrance bridge) at your house. From there, the pair of wires is connected to each phone jack in your house. Along the road runs a thick cable packed with 100 or more copper pairs. Depending on where you are located, this thick cable will run directly to the phone company's switch in your area or it will run to a box about the size of a refrigerator that acts as a digital concentrator. All sizes of telephone cables are available from 2 pairs to 60 pairs. JASOD611 AVSS SHILPI twisted paired cables are best suited for telephone and switchboard cabling applications. the conductor is made of solid annealed, high conductivity bare copper. The conductor is insulated with special grade high-density polyethylene with different colours. The insulated cores are twisted with uniform lay to form pairs and are bunched together in such a manner so as to minimise cross talk. In 50 and 100 pair cables the units of 10 and 20 pairs respectively are identified with colour binders and stranded to form the laid up cable. The laid up cable is further jacketed with a grey colour fire retardant (FR) PVC specially formulated and manufactured in-house, with high oxygen and temperature index. The cables can be used for switchboard and internal telephone wiring in high-rise buildings, offices, factories, hotels, residential complexes, etc. They generally conform to ITD specifications G/ WIR-06/02. May 94. Stringent quality control at every stage, from raw material through manufacturing, upto the finished product, guarantees high quality. Salient Features : » LowAttenuation » LowCrosstalk » FireRetardant Jacket

  • Construction
    Parameters
    1
    Pair
    2
    Pairs
    3
    Pairs
    4
    Pairs
    5
    Pairs
    10
    Pairs
    20
    Pairs
    25
    Pairs
    50
    Pairs
    100
    Pairs
    Conductor (Solid 
    annealed bare
    copper)
    0.4 mm diameter (nom.) & 0.5 mm diameter (nom.)
    Insulation Material
    (0.4 & 0.5 mm dia.)
    High density polyethylene
    Insulation Thickness (Average) 0.4 mm dia. 0.17 mm
    0.5 mm dia. 0.20 mm
    Diameter of Insulated Conductor (Maximum) 0.4 mm dia. 0.74 mm
    0.5 mm dia. 0.92 mm
    Rip cord
    (0.4 & 0.5 mm dia.)
    Nylon
    Colour
    Combination
    For 0.4 mm dia & 0.5 mm dia.
    Pair 01 White-Blue White-Blue White-Blue White-Blue White-Blue White-Blue White-Blue White-Blue White-Blue White-Blue
    Pair 02 White-Orange White-Orange White-Orange White-Orange White-Orange White-Orange White-Orange White-Orange White-Orange
    Pair 03 White-Green White-Green White-Green White-Green White-Green White-Green White-Green White-Green
    Pair 04 White-Brown White-Brown White-Brown White-Brown White-Brown White-Brown White-Brown
    Pair 05 White-Grey White-Grey White-Grey White-Grey White-Grey White-Grey
    Pair 06 Red-Blue Red-Blue Red-Blue Red-Blue Red-Blue
    Pair 07 Red-Orange Red-Orange Red-Orange Red-Orange Red-Orange
    Pair 08 Red-Green Red-Green Red-Green Red-Green Red-Green
    Pair 09 Red-Brown Red-Brown Red-Brown Red-Brown Red-Brown
    Pair 10 Red-Grey Red-Grey Red-Grey Red-Grey Red-Grey
    Pair 11 Black-Blue Black-Blue Black-Blue
    Pair 12 Black-Orange Black-Orange Black-Orange
    Pair 13 Black-Green Black-Green Black-Green
    Pair 14 Black-Brown Black-Brown Black-Brown
    Pair 15 Black-Grey Black-Grey Black-Grey
    Pair 16 Yellow-Blue Yellow-Blue Yellow-Blue
    Pair 17 Yellow-Orange Yellow-Orange Yellow-Orange
    Pair 18 Yellow-Green Yellow-Green Yellow-Green
    Pair 19 Yellow-Brown Yellow-Brown Yellow-Brown
    Pair 20 Yellow-Grey Yellow-Grey Yellow-Grey
    Pair 21   Violet-Blue
    Pair 22   Violet-Orange
    Pair 23   Violet-Green
    Pair 24   Violet-Brown
    Pair 25   Violet-Grey
    No. of Units 1 x 1 P 1 x 2 P 1 x 3 P 1 x 4 P 1 x 5 P 1 x 10 P 1 x 20 P 1 x 25 P 5 x 10 P 5 x 20 P
    Colour of Unit 
    Identification Binder
    For 0.4 mm dia & 0.5 mm dia.
    Unit 1 Unit 1   Blue Blue
    Unit 2 Unit 2   Orange Orange
    Unit 3 Unit 3   Green Green
    Unit 4 Unit 4   Brown Brown
    Unit 5 Unit 5   Grey Grey
    PVC Jacket
    (0.4 mm dia &
    0.5 mm dia.)
    FRPVC compound with high oxygen index
    Approx. Outer Diameter 0.4 mm 2.40 3.10 3.50 3.90 4.30 6.20 8.40 9.30 12.30 16.80
    0.5 mm 3.10 3.90 4.20 5.10 5.60 8.20 10.50 10.70 15.20 20.40
    Packing Length
    (mtrs) 0.4 mm dia
    & 0.5 mm dia.
    100 100 100 100 100 100 100 500 500 500

     

    Electrical Parameters 0.4 mm dia 0.5 mm dia
    Conductor Resistance (max.) ohms/km at 200C 143.0 92.20
    Mutual Capacitance (max.) nf/km 50 50
    Insulation Resistance in Air (min.) M-ohms/km 10,000 10,000
    Capacitance Unbalance Pair to Pair (max.) pF/km 250 250

     






















View Complete Details

HIGH FREQUENCY CO-AXIAL CABLES

  • PAC Bare Copper
  • SCCS Silver Plated Copper Covered Steel
  • TPC Tin Plated Copper
  • BCCS Bare Copper Covered Steel
  • AL/Poly Aluminum / Polyester Foil
  • SPC Silver Plated Copper Braid
  • TPC Tin Plated Copper Braid
  • PE Polyethylene
  • FPE Foam Polyethylene
  • PVC Polyvinylchloride

RG SERIES MIL C 17 TYPE HIGH FREQUENCY CO-AXIAL CABLES RG Wire & Cable Limited provides a comprehensive and complete range of RG Series coaxial cables, in accordance with MiL C 17 specifications. The details of some of the key products are included below; however other products are available, also in non standard designs and colors upon request.

  • Item Inner Conductor Insulating External Conductor Jacket
    Mat
    erial
    Structure Mat
    erial
    Outer Diameter Ma
    terial
    Composition Braid Outside
    /Diameter
    (Max.)
       
    Internal
    Braid
    Configuration
    External
    Braided
    Configuration
    Ma
    terial
    Outer Diameter
    RG5B/U SPC 1/1.29 PE 4.60±0.10 SP
    0043
    0.16 16*9 5.9±10 0.16 16*9 8.7±10 6.73 PVC 8.43±0.10
    RG6A/U PAC *1/0.724 PE 4.70±0.10 SPC 0.16 16*9 5.9±10 0.16 16*9 8.7±10 6.71 PVC 8.43±0.10
    RG8A/U PAC 7/0.724 PE 7.24±0.25 PAC 0.18 24*8 6.5±10 - - - 8.64 PVC 10.3±0.25
    RG9B/U SPC 7/0.724 PE 7.11±0.12 SPC 0.16 24*6 16.6±10 0.16 24*7 15.4±10 9.02 PVC 10.7±0.25
    RG11A/U TPC 7/0.404 PE 7.24±0.17 PAC 0.18 24*8 6.5±10 - - - 8.64 PVC 10.3±0.17
    RG13A/U TPC 7/0.404 PE 7.11±0.25 PAC 0.16 24*9 6.5±10 0.16 24*8 10.3±10 9.02 PVC 10.7±0.25
    RG14A/U PAC 1/2.59 PE 9.40±0.33 PAC 0.18 24*10 5.4±10 0.18 24*8 10.6±10 11.8 PVC 13.8±0.33
    RG17A/U PAC 1/4.78 PE 17.3±0.38 PAC 0.26 24*14 3.1±10 - - - 19.3 PVC 22.1±0.38
    RG34B/U PAC 7/0.632 PE 11.7±0.25 PAC 0.18 24*10 9±10 - - - 13.6 PVC 16.0±0.25
    RG55B/U SPC 1/0.813 PE 2.95±0.12 TPC 0.127 16*7 9±10 0.12 16*7 15±10 4.47 PE 5.25max.
    RG58C/U TPC 19/0.18 PE 2.95±0.10 TPC 0.127 16*7 10.3±10 - - - 3.81 PVC 4.95±0.10
    RG59B/U CCS 1/0.584 PE 3.71±0.10 PAC 0.16 16*7 8.2±10 - - - 4.85 PVC 6.15±0.10
    RG62A/U CCS 1/0.643 PE 3.71±0.12 PAC 0.16 16*7 8.2±10 - - - 4.85 PVC 6.15±0.17
    RG63B/U CCS 1/0.643 PE 7.24±0.25 PAC 0.18 24*8 6.5±10 - - - 8.64 PVC 10.2±0.25
    RG71B/U CCS 1/0.643 PE 3.71±0.12 TPC 0.127 16*7 8.2±10 0.12 16*9 10.6±10 5.28 PE 6.35max.
    RG122/U TPC 27/0.127 PE 2.44±0.07 TPC 0.127 16*6 12.9±10 - - - 3.2 PVC 4.05±0.12
    RG133A/U PAC 1/0.645 PE 7.24±0.17 PAC 0.18 24*8 6.5±10 - - - 8.64 PVC 10.3±0.25
    RG174 CCS 7/0.16 PE 1.52±0.10 TPC 0.12 16*4 12±10 - - - 1.98 PVC 2.79±0.10
    RG212/U CCSS 1/1.41 PE 4.70±0.10 SPC 0.16 16*9 5.9±10 0.16 16*9 8.7±10 6.73 PVC 8.43±0.10
    RG213/U PAC 7/0.752 PE 7.24±0.17 PAC 0.18 24*8 6.5±10 - - - 8.64 PVC 10.3±0.17
    RG214/U TPC 7/0.752 PE 7.24±0.17 SPC 0.16 24*6 16.6±10 0.16 24*7 15.4±10 9.14 PVC 10.8±0.17
    RG215/U TPC 7/0.752 PE 7.24±0.17 PAC 0.18 24*8 6.5±10 - - - 8.64 PVC 10.3±0.17
    RG217/U PAC 1/2.69 PE 9.40±0.25 PAC 0.18 24*10 5.4±10 0.18 24*8 10.6±10 11.8 PVC 13.8±0.25
    RG223/U SPC 1/0.889 PE 2.95±0.10 SPC 0.127 16*7 9±10 0.127 16*7 10±10 4.47 PVC 5.50max.
    Electrical Characteristics
    Item Attenuation (Max.) Characteristic Impedance Standard capacitance Max. Working Voltage Standard Attenuation
    1 MHz 10 MHz 30 MHz 100 MHz 300 MHz 1000 MHz 300 MHz
    dB/km MHz Q nF/km kV dB/km
    RG5B/U 213 400 50±2 93.5 3.0 - - - 79 141 289 548
    RG6A/U 213 400 75±3 67.3 2.7 - 28 48 92 171 361 656
    754 3000
    RG8A/U 197 400 52±2 96.8 4.0 - - - 69 138 295 590
    RG9B/U 200 400 50±2 98.4 4.0 - - - 75 138 285 584
    715 3000
    RG11A/U 171 400 75±3 67.3 4.0 7.1 23 41 76 139 - -
    605 3000
    RG13A/U 187 400 74±3 67.3 4.0 7.1 23 41 76 139 - -
    RG14A/U 141 400 52±2.5 96.8 5.5 - - - 46 92 204 426
    459 3000
    RG17A/U 92 400 52±2 96.8 11.0 - - - 28 59 138 328
    361 3000
    RG22B/U 345 3000 95±5 52.5 1.0 - - 56 118 230 - -
    RG34B/U 125 400 75±3 67.0 5.2 4.3 13 25 48 90.0 - -
    RG55B/U 384 400 53.5±2.5 93.5 1.9 - 33 66 138 259 525 1000
    RG58C/U 459 400 50±2 93.5 1.9 - 43 82 174 315 721 1480
    1640 3000
    RG59B/U 295 400 75±3 67.3 2.3 - 34 60 112 202 - -
    983 3000
    RG62A/U 263 400 93±5 44.3 0.75 - 33 56 102 181 328 590
    RG63B/U 187 400 125±6 32.8 1.0 - 20 36 66 118 230 394
    RG-71B/U 263 400 93±5 44.3 0.75 - 33 56 102 180 328 590
    RG122/U 590 400 50±2 105 1.9 - - - 195 345 655 -
    RG133A/U 187 400 95 53 4.0 7.1 23 40 76 140 - -
    RG174/U 630 400 50±2 101 1.1 - 190 - 380 - 860 -
    RG212/U 213 400 50±2 100 2.5 - - - 89 162 320 624
    787 3000
    RG213/U 181 400 50±2 100 4.0 - - - 69 128 257 515
    623 3000
    RG214/U 181 400 50±2 100 4.0 - - - 67 123 249 501
    623 3000
    RG215/U 181 400 50±2 100 4.0 - - - 73 134 268 535
    623 3000
    RG217/U 141 400 50±2 100 6.0 - - - 50 94 196 410
    459 3000
    RG223/U 384 400 50±2 100 1.9 - - - 129 230 443 938
    1320 3000
       











View Complete Details

MULTICORE OVERALL SCREENED DATA CABLES

  • Uses For RS 232 data transmission and instrumentation applications.
  • Conductor Tinned annealed high conductivity copper wire to BS 6360.
  • Insulation PVC/PE/XLPE/LSOH
  • Overall Screen Aluminium/Polyester Tape or Copper Braiding, Sheath: PVC/LSOH

Multicore overall screened data cables have individually insulated cores laid up in an aluminum/polyester tape. A tinned copper drain wire is laid under and in contact with the screen.

  • Part No. No. of Pairs Insulation Type Conductor Size(AWG) Max inner Conductor Resistance (Ohm/Km) Capacitance (pF/m) Overall Diameter (m m)
    C1 C2
    Multicore Overall Screen data cables SCD0324Y 3 PVC 24 85 107 193 4.4
    Multicore Overall Screen data cables SCD0424Y 4 PVC 24 85 107 193 4.7
    Multicore Overall Screen data cables SCD0524Y 5 PVC 24 85 107 193 4.8
    Multicore Overall Screen data cables SCD0624Y 6 PVC 24 85 107 193 5.3
    Multicore Overall Screen data cables SCD0724Y 7 PVC 24 85 107 193 5.4
    Multicore Overall Screen data cables SCD0824Y 8 PVC 24 85 107 193 5.8
    Multicore Overall Screen data cables SCD1024Y 10 PVC 24 85 107 193 6.1
    Multicore Overall Screen data cables SCD1524Y 15 PVC 24 85 107 193 7.4
    Multicore Overall Screen data cables SCD2524Y 25 PVC 24 85 107 193 9.2
    Multicore Overall Screen data cables SCD0322Y 3 PVC 22 54.8 105 185 5.4
    Multicore Overall Screen data cables SCD0620Y 6 PVC 20 34.1 80 158 7.9
    Multicore Overall Screen data cables SCD1220Y 12 PVC 20 34.1 80 158 10.9
    Multicore Overall Screen data cables SCD0418Y 4 PVC 18 23 200 340 6.4
    Multicore Overall Screen data cables SCD0322E 3 PE 22 54.8 62 115 5.3
    Multicore Overall Screen data cables SCD0422E 4 PE 22 54.8 65 128 6.7
    Multicore Overall Screen data cables SCD0320E 3 PE 20 34.1 85 162 5.7
    Multicore Overall Screen data cables SCD0318E 3 PE 18 23 70 130 6.3
    Multicore Overall Screen data cables SCD0316E 3 PE 16 15.8 80 160 8.2
View Complete Details

Solar Cable

Solar cable is the interconnection cable used in photovoltaic power generation. A solar cable interconnects solar panels and other electrical components in the photovoltaic system. Solar cables are designed to be UV resistant and weather resistant. It can be used within a large temperature range and are generally laid outside. The cable is tested to last 25 years. All sizes of solar cables from 0.5 SQMM to 300 SQMM are available. Special Properties of Solar Cables Lifetime reliability: lasts up to 30 years even under tough external conditions. Outdoor durability: resists extreme temperatures (-40°C to 120°C maximum at the core) and ozone resistant. UV resistance: full protection against ultraviolet rays. Halogen-free: Low Smoke Emission & Low Toxicity/Corrosivity during fire. Properties against fire: flame retardant, fire retardant. Flexibility and stripability: for fast and easy installation. Fully recyclable: in accordance with new environmental regulations. Easy installation with color identification (blue, red). Suitable to common connector types. UL, TÜV, UTE and IMQ-certified. Constituents Shilpi Solar Cables are manufactured with the following materials Annealed Tinned Copper Conductor Cross Linked Polyolefin Compound Zero Halogen Polyolefin Compound Required Features of Solar cable Chemical Features Weather resistant Resistant to mineral oils Resistant to acids & alkaline Thermal Features Maximum conductor temperature of operation-120° C during 20000 hours Minimum operating temperature: - 40° C Electrical Features Voltage rating : 1.5 (1.8) KV DC / 0.6/1.0 (1.2) KV AC High voltage test: 6.5 KV DC for 5 minutes. Mechanical Features Resistant to Impact , tear & abrasion Minimum bending radius – 4 times of overall diameter. Safe pulling force -50 N/sqmm.

  • Solar DC Cables from PV Module to Array Juntion Box (as per TUV Specifications-2 Pfg 1169/08.2007)
    Single Core Size in Sq.mm Max. Conductor Diameter in mm XL-LSOH Insulation Thickness-Nominal in mm XL-LSOH Sheathing Thickness-Nominal in mm Overall Dia. Nominal in mm
    1.5 0.26 0.7 0.9 5.0 +/-0.5
    2.5 0.26 0.7 0.9 5.5 +/-0.5
    4 0.31 0.7 0.9 6.0 +/-0.5
    6 0.31 0.7 0.9 6.5 +/-0.5
    Solar DC Cables from Array Junction Box to Main Juntion Box & MJB to Inverter (as per TUV Specifications-2 Pfg 1169/08.2007)
    10 0.41 0.7 0.9 7.5 +/-0.5
    16 0.41 0.7 0.9 8.5 +/-0.5
    25 0.41 0.9 1 10.5 +/-0.7
    35 0.41 0.9 1.1 12.0 +/-0.7
    50 0.41 1 1.2 14.0 +/-0.7
    70 0.51 1.1 1.3 16.0 +/-1.0
    95 0.51 1.1 1.5 18.5 +/-1.0
    120 0.51 1.2 1.6 20.0 +/-1.0
    150 0.51 1.4 1.7 22.5 +/-1.0
    185 0.51 1.6 1.9 25.0 +/-1.0
    240 0.51 1.7 2.1 28.0 +/-1.0
    Solar DC Cables from PV Module to Array Juntion Box (as per IS 694 & IS 1554 Part I guidelines)
    Single Core Size in Sq.mm Max. Conductor Diameter in mm HR 105°C PVC Insulation Thickness-Nominal in mm UV HR 105°C PVC Sheathing Thickness-Nominal in mm Overall Dia. Nominal in mm
    1.5 0.26 0.6 0.9 5.0 +/-0.5
    2.5 0.26 0.7 0.9 5.5 +/-0.5
    4 0.31 0.8 0.9 6.5 +/-0.5
    6 0.31 0.8 0.9 7.0 +/-0.5
    Solar DC Cables from Array Junction Box to Main Juntion Box & MJB to Inverter (as per IS 694 & IS 1554 Part I guidelines)
    10 0.41 1.0 0.9 8.5 +/-0.5
    16 0.41 1.0 0.9 9.5 +/-0.5
    25 0.41 1.2 1.0 11.0 +/-0.7
    35 0.41 1.2 1.1 12.5 +/-0.7
    50 0.41 1.4 1.3 15.0 +/-0.7
    70 0.51 1.4 1.4 17.0 +/-1.0
    95 0.51 1.6 1.5 19.5 +/-1.0
    120 0.51 1.6 1.6 21.0 +/-1.0
    150 0.51 1.8 1.8 23.5 +/-1.0
    185 0.51 2.0 1.9 25.5 +/-1.0
    240 0.51 2.2 2.2 29.5 +/-1.0
View Complete Details

2 Way Power Splitter

  • Color Black
  • Color Black Plated
  • Application Indoor/Outdoor
  • Device Type Splitter
  • Interface N Female
  • Inner Contact Plating Silver
  • Outer Contact Plating Tri-metal
  • Ingress Protection Test Method IEC 60529:2001, IP65
  • Operating Temperature -25°C to +85 °C (-13°F to +185 °F)
  • Relative Humidity 5%-95%
  • Height 60 mm
  • Length 242 mm
  • Net Weight 215 g
  • Width 25 mm
  • Electrical Operating Frequency Band
  • 700-2700 MHz 3rd Order IMD
  • -150 dBc (relative to carrier) 3rd Order IMD Test Method
  • Two +43 dBm carriers Average Power, maximum
  • 300 W Dissipative Loss at Frequency Band
  • ±0.3 dB @ 700-2700 MHz Impedance
  • 50 ohm Return Loss
  • 19.1 dB Split Loss
  • 3.0 dB VSWR
  • 1.25:1 Packed Dimensions
  • Height 90 mm
  • Length 265 mm
  • Width 75 mm

View Complete Details

dB HYBRID COUPLER

  • Height 90 mm
  • Length 265 mm
  • Width 75 mm
  • Application Indoor
  • Ingress Protection Method IEC 60529:2001, IP 65
  • Operating Temperature -40°C to +75 °C
  • Relative Humidity 5%-95%
  • Inner Contact Plating Silver
  • Outer Contact Plating Tri- Alloy
  • Dimension (LxWxH) 123x75x20 mm
  • Weight 300gm
  • General Device Type
  • Combiner 2:2 Interface 
  • N Female Color
  • Black Plated/Grey Plated Electrical
  • Operating Frequency Band 700-2700 MHz
  • Impedance 50 ohm
  • Coupling 3.0 dB
  • Coupling Tolerance ±0.5 dB
  • VSWR ≤1.25:1
  • Return Loss 19.2 dB
  • Insertion Loss ≤0.25dB @ 700-2700 MHz
  • Isolation ≥20 dB @ 700-2700 MHz
  • Termination N Female
  • 3rd Order IMD -156 dBc ( Relative to Carrier)
  • 3rd Order IMD Test Method Two +43 dBm Carriers
  • Power Handling 150 Watts

View Complete Details

OMNI-DIRECTIONALFIBERGLASS ANTENNA

  • Size -mm ø25*900
  • Antenna weight-kg 0.8
  • Working Temperature -°c -40~60
  • Rated Wind Velocity-m/s 60
  • Radome color gray
  • Mounting way hold in the pole
  • Electrical Frequency rang-MHz
  • 806~960 Bandwidth -MHz
  • 154 Gain -dBi
  • 8 beam width -°
  • H: 360 V: 17 VSWR
  • ≤1.5 Input Impedance-Ω
  • 50 Polarization
  • Vertical Max power -W
  • 100 Lightning protection
  • DC ground Connector model

Description: CDMA800/GSM900 mobile system Repeater antenna , station antenna Point to point & Multipoint system

View Complete Details

NON-RELEASABLE CABLE TIE

  • External Length / Height 100/200/300/400 mm
  • External Width 2.5/3.6/4.8/4.6/7.6mm
  • Flammability Rating UL94V-2
  • Standard US mil Spec 23190
  • Drwg MQT/
  • Tensile Strength (kg): 54.4kg
  • Tensile Strength N/mm²: 535N/mm²
  • Package Content 100
  • Description Value
  • Cable Tie Length: 100/200/300/400 mm
  • Body Material Nylon 6.6
  • Cable Tie Colour Black /White
  • Tensile Strength N/m²: 535N/mm²
  • Cable Tie Width 2.5/3.6/4.8/7.6mm
  • Cable Bundle Diameter Min 1.5/3.0mm
  • Cable Bundle Diameter Max 22/50/85/100/110mm
  • Accessory Type Cable Tie
  • Cable Diameter Max 75mm
  • Cable Diameter Min: 5mm

Description: Available in a wide range of materials, these cable ties all feature internal serrations allowing for a positive hold onto cable and pipe bundles. The design of the head guarantees a high tensile strength whilst allowing a very low insertion force, this, combined with the bent tail design of many of the ties ensures a simple and quick installation. Whilst easily installed by hand, - manual and pneumatic (for high volume applications) tensioning tools are available to ensure consistency of installation. Application Method Quick, simple fixing by hand or with tensioning tools Features Non Releasible ties once locked can not be opened or reduced Self Locking and one piece construction which ensures the fast and easy installation

  • L Length mm W Width mm T Thickness mm Length (Inch) Type Tensile Strength Kg(lbs) Std. Qty/Bag
    104 2.5 1.06 4 Miniature 8(18) 100/1000
    153 3.6 1.25 6 Intermediate 18(40) 100
    204 3.6/4.6 1.29 8 Standard 22(50) 100
    254 4.8 1.43 10 Standard 22(50) 100
    306 4.6/4.8 1.56 12.4 Standard 22(50) 100
    380/400 4.8/7.6 1.78 15 Heavy Duty 55(120) 100
View Complete Details

patch chords

Description Fiber optic patch cords form the all important link between complex electronic system components and the fiber plant. patch cords are available in all standard connector styles, all standard fiber types and all standard cable configurations to meet all your interconnection needs. They are available in any length and are factory terminated, assembled, tested and inspected prior to shipment. These assemblies meet IEC, JIS and Belcore performance requirements as applicable. All Wirewerks patch cords are RoHS compliant facilitating use in European applications. Custom patch cord assemblies are also available upon request. Applications Telecommunications CATV LAN & WAN Broadband FTTP Features and Beneifits Meet IEC, JIS, Bellcore GR-326 performance requirements Guaranteed quality; 100% Tested and Inspected Custom assemblies available Telecommunications CATV LAN & WAN Broadband FTTP

  • Item SM MM
      PC APC UPC 62.5/1.25 50/125 50/125 10G
    Insertion Loss*, Single Fiber Conn. 0.2dB Max. (0.15dB typ.) 0.3dB Max. (0.25dB typ.)
    Insertion Loss*, MTRJ 0.5dB Max. (0.45dB typ.) 0.5dB Max. (0.45dB typ.)
    Return Loss ≥ 45 dB ≥ 50 dB ≥ 60 dB na
    Durability 0.2 dB max increase
    Operating Temp. -40 ºC to +85ºC
    Storage temp. -40 ºC to +85ºC
    Other Ferrule Concentricity < 1μm
       

     

    A B C D E F G
    A-Core size B-Cable Type C-Conn. #1 D-Polish #1 E-Conn. #2 F-Polish #2 G-Length in M
    1=Singlemode A=Duplex 3mm zip riser SC=SC A=APC SC=SC A=APC xxx=xxx meters
    2=62.5/125 B=Duplex 3mm zip plenum ST=ST B=UPC ST=ST B=UPC  
    3=50/125 C=Simplex 3mm riser LC=LC C=PC LC=LC C=PC  
    4=50/125 10Glb D=Simplex 3mm plenum FC=FC   FC=FC    
      E=Duplex 2mm zip riser MT=MTRJ   MT=MTRJ    
      F=Duplex 2mm zip plenum S5=SMA905   S5=SMA905    
      G=Simplex 2mm riser S6=SMA906   S6=SMA906    
      H=Simplex 2mm plenum E2=E2000   E2=ESCON    
      I=Duplex 1.8mm riser ES=ESCON   FD=FDDI    
      J=Duplex 1.8mm plenum FD=FDDI   D4=D4    
      K=900 um D4=D4        
      L=250um          
      R=Duplex 3mm LSZH          
      S=Duplex 1.8mm LSZH        

     

View Complete Details

Wiring Harness

WIRING HARNESS Wiring Harness for each vertical of automotive Industry, as small as 2 wheeler to as big as Commercial vehicle harness, Shilpi Cable gives solutions to wiring connectivity of a vehicle from modular to complete assembly from head to tail Harness for 2/3 Wheelers Harness for Commercial Vehicles Harness for Utility Vehicles Harness for Tractors Note: Values typical, guaranteed within 5 % Any dimension could be changed without prior information under the organization's continual

View Complete Details

Power Connector

We are an established manufacturer, supplier, and exporter of wide array of power connector, and power code. We are one of the prominent and dependable power connector manufacturers that serve the ever-growing requirements of Indian Power Sector Industry for more then a decade. Our manufactured range of power connector is broadly used to join cables, wires or various machines parts and manufactured with different high grade material of construction such as plastic, fiber, iron etc. Our product line is renowned for the distinguished features like corrosion resistant finish, excellent performance, operational fluency and polished surface. To manufacture our products, we adhere to all the prevailing rules and regulations of industry.  

  • Cable Description Rating
    IS 2 x 0.5 mmsq Straight IEC C7 connector 2.5 A , 250 V
    IS 2 x 0.75 mmsq Straight IEC C7 connector 2.5 A , 250 V
    VDE H05VVF 2 x 0.5 mmsq Straight IEC C7 connector 2.5 A , 250 V
    VDE H05VVF 2 x 0.75 mmsq Straight IEC C7 connector 2.5 A , 250 V
View Complete Details

Single Core Cable

Horizontal Wiring Non-CMR LAN Cable

House Wires


Tell Us What are you looking for? Will call you back

Contact Us

  • SHILPI WORLDWIDE DMCC
  • Unit No. 3O-01-385, Floor No. 1 Building No. 3, Plot No. 550-554 J & G Complex, Almas Towers DMCC, Dubai, United Arab Emirates. P.O. Box No. 11324, Dubai, United Arab Emirates