Our Products
Our product range contains a wide range of Solar Cable
Solar cable is the interconnection cable used in photovoltaic power generation. A solar cable interconnects solar panels and other electrical components in the photovoltaic system. Solar cables are designed to be UV resistant and weather resistant. It can be used within a large temperature range and are generally laid outside.
The cable is tested to last 25 years. All sizes of solar cables from 0.5 SQMM to 300 SQMM are available.
Shilpi Solar Cables are manufactured with the following materials
Solar DC Cables from PV Module to Array Juntion Box (as per TUV Specifications-2 Pfg 1169/08.2007) | ||||
Single Core Size in Sq.mm | Max. Conductor Diameter in mm | XL-LSOH Insulation Thickness-Nominal in mm | XL-LSOH Sheathing Thickness-Nominal in mm | Overall Dia. Nominal in mm |
1.5 | 0.26 | 0.7 | 0.9 | 5.0 +/-0.5 |
2.5 | 0.26 | 0.7 | 0.9 | 5.5 +/-0.5 |
4 | 0.31 | 0.7 | 0.9 | 6.0 +/-0.5 |
6 | 0.31 | 0.7 | 0.9 | 6.5 +/-0.5 |
Solar DC Cables from Array Junction Box to Main Juntion Box & MJB to Inverter (as per TUV Specifications-2 Pfg 1169/08.2007) | ||||
10 | 0.41 | 0.7 | 0.9 | 7.5 +/-0.5 |
16 | 0.41 | 0.7 | 0.9 | 8.5 +/-0.5 |
25 | 0.41 | 0.9 | 1 | 10.5 +/-0.7 |
35 | 0.41 | 0.9 | 1.1 | 12.0 +/-0.7 |
50 | 0.41 | 1 | 1.2 | 14.0 +/-0.7 |
70 | 0.51 | 1.1 | 1.3 | 16.0 +/-1.0 |
95 | 0.51 | 1.1 | 1.5 | 18.5 +/-1.0 |
120 | 0.51 | 1.2 | 1.6 | 20.0 +/-1.0 |
150 | 0.51 | 1.4 | 1.7 | 22.5 +/-1.0 |
185 | 0.51 | 1.6 | 1.9 | 25.0 +/-1.0 |
240 | 0.51 | 1.7 | 2.1 | 28.0 +/-1.0 |
Solar DC Cables from PV Module to Array Juntion Box (as per IS 694 & IS 1554 Part I guidelines) | ||||
Single Core Size in Sq.mm | Max. Conductor Diameter in mm | HR 105°C PVC Insulation Thickness-Nominal in mm | UV HR 105°C PVC Sheathing Thickness-Nominal in mm | Overall Dia. Nominal in mm |
1.5 | 0.26 | 0.6 | 0.9 | 5.0 +/-0.5 |
2.5 | 0.26 | 0.7 | 0.9 | 5.5 +/-0.5 |
4 | 0.31 | 0.8 | 0.9 | 6.5 +/-0.5 |
6 | 0.31 | 0.8 | 0.9 | 7.0 +/-0.5 |
Solar DC Cables from Array Junction Box to Main Juntion Box & MJB to Inverter (as per IS 694 & IS 1554 Part I guidelines) | ||||
10 | 0.41 | 1.0 | 0.9 | 8.5 +/-0.5 |
16 | 0.41 | 1.0 | 0.9 | 9.5 +/-0.5 |
25 | 0.41 | 1.2 | 1.0 | 11.0 +/-0.7 |
35 | 0.41 | 1.2 | 1.1 | 12.5 +/-0.7 |
50 | 0.41 | 1.4 | 1.3 | 15.0 +/-0.7 |
70 | 0.51 | 1.4 | 1.4 | 17.0 +/-1.0 |
95 | 0.51 | 1.6 | 1.5 | 19.5 +/-1.0 |
120 | 0.51 | 1.6 | 1.6 | 21.0 +/-1.0 |
150 | 0.51 | 1.8 | 1.8 | 23.5 +/-1.0 |
185 | 0.51 | 2.0 | 1.9 | 25.5 +/-1.0 |
240 | 0.51 | 2.2 | 2.2 | 29.5 +/-1.0 |