Our Products
Circuit Breaker
2 Products availableInstrumentation & Control Equipment
2 Products availableRailway Components
1 Products availableElectric Circuit Components & Parts
1 Products availableProcess Control Systems & Equipment
1 Products availablePower Contactors
1 Products availableFuses, Circuit Breakers & Components
1 Products availableMeasuring Instruments & Equipment
1 Products availableWater Pumps
1 Products availableWe offer the best product range of Supertech Wiring Devices and Ats Panels.
MCB'S Rating up to 80A
MCB'S available SP, DP, TP, AP
MCB'S in type B, C, D 6KA & 10ICA
Isolators Up to 125A for 2, 3&4 Poles RCCB'S 2 & 4 Poles up to 100A
Sensitivity 30mA, 100mA, 300mA
RCBO's 1 & 2 Modules in 6 & 10 KA Modular Contactor 1, 2, 3&4 Poles 25 & 63A
Rating up to 1600A 6 frame sizes
1, 2, 3, 4, poles versions
Short Circuit Breaking Capacity upto 70 KA Fixed and Plug-in type
All Accessories are available for all ranges. Provided with phase barrier
Rating starting from 630A upto 6300A
3 and 4 pole version
Fixed and drawout type
Run-Auto version in 3 & 4 Poles
Trip unit with display and communication facility Mechanical Interlocking facility for 3 & 4 pole version UVR, Short trip, motor operator and Aux. contacts are available for all ranges.
Suitable for power supply system AC 50/60 HZ with main circuit voltage 380V
Available upto 50 RVAR
Provided with capacitor switching unit
Microprocessor based intelligent auto switching control
Automatic C/K and rated step adjustment
Automatic CT polarity correction
Display of power factor, current & total harmonic distortion of current
Programmable sensitivity
Last step can be used as alarm/fan output
Under/over voltage alarm, under/over compensate alarm & high harmonic distortion alarm
Range 100 A up to 125 A, 4 poles
Function
The controller tests the voltage of two lines of power supply. When the voltage is higher than 110% of rated value, it is regarded as over voltage. When the voltage is lower than 85% of rated value, it is regarded as under voltage. The microcomputer controlled circuit will conduct logic judgment of testing result, and the dealing result will send ON & OFF directive to the electrical operation mechanism by delay (adjustable) circuit drive. And the above-mentioned testing result will be displayed on LCD screen of automatic controller.
AC contactors is mainly used in the circuit of AC 50Hz/60Hz, rated working voltage up to 630A when rated voltage 380 under AC-3 usage category for long distance making and breaking circuit frequently starting and controlling AC motor, and it can be formed into electromagnetic starter with thermal relay for protecting circuit from the problem operating overload.
W/P Isolators are used as a maintanance switch to prevent from being turned on by unauthorized personnel, or during maintenance or repair work.
Provided with steel or plastic Enclosures
IP 65 Degree Of Protection
Light Grey ( RAL 7032 )
High Breaking Capacity ( AC 21 & 22A & 23A )
Double Break Contacts
Available with 9 different ranges from 16A up to 3150A Conformed to IEC 60947-1 and IEC 60947-3
Salient Features
-/5A in class 1.0 accuracy
CT Primary Programmable upto 6000A (For direct reading)
Display I scroll mode :-
Active Energy kWh, Apparent Energy kVAh, Reactive Energy kVArh, Phase to phase voltage, Phase to Neutral Voltage, Instantaneous, Average, Maximum and total Current, Active Power kW, Reactive Power kVAr an Apparent Power kVa, Instantaneous and total Power Factor, Frequency
Maximum demand in kVA / kW with integration Period of 30 Minutes (Optional)
Real Time &Date (Optional)
Pulse output
RS485 Communication (Optional)
Its versatality make Supertech, for best choice which can be installed of anywhere in the world as per British, European and other standards. It covers any kind of building from Residential, Commercial, Industrial and Hospitals.
Extensive range of 2 pump sets controlled by pressure switches or pressure transmitters, with constant or variable speed operation. The range has been designed to supply water to domestic users on an intermittent and variable basis, using electric motors controlled from an electric panel.
To Improve the P.F. to reduce the power losses.
Can be provided to detuned reactors to protect the capacitors being damaged due to the harmonics
Capacitor bank can be integrated as a part of the main switchboard or as a stand alone unit.
Provided with P.F. controller of 4, 6, 12 steps.
Each step is protected by HRC fuse directly installed on the busbar system to insure proper cooling of busbar system and to protect the busbar from human touch and gain more space inside the capacitor bank for better ventilation.
Complying as per IEC 61439
Front or rear access arrangement with separate cabling chambers for top or bottom cable entry. Protection degree of the enclosure is IP30 or IP40 for Form 2 or Form-4
The drawer panel is marked with obvious signs for positions as breaking, making, testing and drawing out
The drawer unit is provided with mechanical interlock device.
Easy mechanism for pushing drawer up to 630A
Main Incomer can be Isolator or MCCB
Protection degree of the enclosure is IP40 or IP65
KA rating up to 50KA
Main incommer up to 1200 A with as any number of outgoing MCCB'S
Cable entry can be top or bottom
Busbar system can be provided as a pan assembly or
Fabricated as per the panel configuration.
Can be provided with Motorized isolator type Motorized MCCB with mechanical interlock contactor type can be provided with single and double bybass system