Our Products
Domestic Luminaires
2 Products availableElectric Control Panels
2 Products availableAutomotive Lights
1 Products availableRound Rubber Seals
1 Products availableSafety Lights
1 Products availableSpying & Intelligence Devices
1 Products availableElectrical Conduit Fitting
1 Products availableWe offer the best product range of Explosionproof Thermostat, Cable Sealing Device, Non-armoured Barrier Gland, ET Elbow and Tee and Commercial & Military Aviation Ground Power.
Champ F2MV Mini HID Hazardous Area Floodlights
The Crouse-Hinds series Champ F2MV HID floodlight is a compact, easy-to-install floodlight for use in Class I, Division 2 and Zone 2 hazardous areas.
Manufactured with a Corro-free epoxy coated copper-free aluminum enclosure, stainless steel external hardware and impact-resistant glass, the F2MV is available with the following mogul base HID lamp types and wattages:
The F2MV is suitable for marine and wet locations.
Certifications and compliancesNEC and CEC
UL standards
CSA standards
IEC standard
The Champ-Pak Wall Pack Luminaire is ideal for low-profile mounting in hazardous and industrial environments. In fact, it is suitable for any area with adverse conditions such as dust, dirt, moisture, vibration, high-pressure hose downs, and high thermal ambients. Applications include:
Conduit Entries | Four 3/4" NPT entries, one on each side, top and bottom (3 plugged); two 1/2" NPT entries on bottom for feed through (1 plugged); consult factory for metric entries |
Wattages | High pressure sodium mogul base 50, 70, 100, 150W; metal halide mogul base 70, 100, 150W; compact fluorescent 26, 32, 42, 52, 64, 84W; auxiliary fluorescent 26W; induction 55, 85W |
FEATURES
V Series Incandescent Luminaires are used:
FEATURES
For use in:
Available Accessories | Narrow Spot Lights Type (NSP*); Wide Floodlight Type (WFL*); SS Guard (G); Handle and Clamp (HDL); 12V Med Floodlight Type 300W (-12); 28V Med Floodlight Type 450W (-28**) *120V only. **10 hour lamp life. |
For use in:
TCH Explosionproof Clocks are used:
FEATURES
EXH Explosionproof Electric Heaters are used:
HRC Thermostats are used:
HRC Bimetal Thermostats are used:
FEATURES
HRC Thermostat with Honeywell Control:
HRC Bimetal Thermostat:
D2PB Circuit Breaker Panelboards are designed specifically for use:
FEATURES
PowerPlus Panelboards provide premium factory sealed and value non-factory sealed solutions for the protection and distribution of lighting, power, and heat tracing circuits.
PowerPlus D2D Panelboards are used:
PowerPlus Panelboards provide premium factory sealed and value non-factory sealed solutions for the protection and distribution of lighting, power, and heat tracing circuits.
PowerPlus EPL Panelboards are used:
Eaton's Crouse-Hinds series Link-Sealis the quick, economical way to seal around conduit in concrete walls, floors and casings. Link-Seal is a modular mechanical seal used for any type of penetration.
FEATURESThe Thru-Wall Barrier is designed:
For use with non-armored, marine shipboard, Type P and tray cable, ADE-1FC non-armored barrier glands are installed:
Please note this product has been revised to comply with IEC 60079-0: 2011 Ed.6.
FEATURESDesigned for use in IEC electrical systems, C30 and C31 conduit outlet boxes are installed within hazardous areas to:
GRUE outlet boxes are intended for use within hazardous areas to:
LBH conduit outlet bodies, and SLB and LBY elbows are installed in hazardous areas to:
ET short radius tees:
LBH bodies:
SLB elbows have:
LBY elbows have:
ET short radius tees have:
STL thread lubricant is used between any screw thread and its tapped opening, on any rotating shaft threaded or plain, and to inhibit corrosion on any metal-to-metal joint of apparatus and control enclosures.
HTL high temperature lubricant is used on lighting fixture threaded joints and on threaded joints of the enclosures of any heat-producing apparatus or control.
STL is lithium based, anti-galling, and:
HTL is a high temperature, anti-seize, conductive thread lubricant:
Cast device boxes are installed in conduit and cable systems to:
Eaton's aviation solutions include Burton and Titan Ground Power plugs, cable assemblies and receptacles. Innovations include glass-filled epoxy carriers and floating contacts (depicted to the left) that extend the service lives of GPU cables and aircraft receptacles by reducing the forces required for mating and demating. Additional Titan Ground Power features include:
Micro-Mini AC Dual Key products have been specifically designed for low amperage AC control systems and are ideally suited for use in harsh and abusive manufacturing environments.
ECC products are a rugged combination of molded-to-cable male plugs and terminal back female receptacles. The receptacle is designed for convenient mounting on standard FS or FD wiring boxes. The plug is furnished molded to various lengths of either cross-link polyethylene or poly vinyl-chloride, 600 volt cable. The ECC connector has found widespread use in applications where operating conditions are demanding, and the utmost in reliability is required due to the high cost of downtime.
Macey 25kV coupling systems are used to supply power to draglines, longwall machines, cranes and other types of equipment.
FEATURESOne of the biggest challenges with enclosures located in hazardous areas is accessibility. To access internal components for preventative maintenance or troubleshooting, up to 70 bolts have to be loosened and then retightened, leading to extended periods of downtime and safety risks due to improperly torqued or missing bolts.
The clamped EBMX enclosure utilizes patented clamping technology to reduce downtime, increase safety and lower maintenance costs.
Applications:
One of the biggest challenges with enclosures located in hazardous areas is accessibility. To access internal components for preventative maintenance or troubleshooting, up to 70 bolts have to be loosened and then retightened, leading to extended periods of downtime and safety risks due to improperly torqued or missing bolts.
The clamped EBMX enclosure utilizes patented clamping technology to reduce downtime, increase safety and lower maintenance costs.
Applications:
*Standard factory wiring included between the starter and breaker consult factory for any additional wiring requirements.
AFA/AFAX Conveyor Belt Alignment Switches are used:
AFU Conveyor Belt Switches are used:
D2X Attachable Pendant Pushbutton Stations are used:
EGF Explosionproof Ground Fault Control Stations are used:
Provides producers, handlers and manufacturers of combustible materials a safe product transfer solution with low maintenance, simple installation and reliable operational benefits at a competitive price.
FEATURESAn explosionproof enclosure built to customer-specific needs, allowing for the grouping of control devices for process control in minimum space requirements. Available in a variety of sizes with an unlimited combination of devices, windows and markings, these panels are designed to maximize the efficiency of each unique process.
FEATURESEMP and EMPS Explosionproof Barrel Assemblies for Control Stations:
IEC AFT Conveyor Belt Ripped/Torn Switches are used:
ArktiteAPQ Series 30-100A Motor Plugs are used:
Eaton's subsea penetrators are designed for applications that require maximum pressure protection and minimal maintenance over long-term deployments. An extensive array of solutions includes Burton subsea products and penetrators that were formerly promoted under the Electro-Oceanic name:
WLRS, WLRD and WLGF covers are suitable for use in wet and damp locations (WLGF suitable only when cover is closed).
Use WLRS, WLRD and WLGF:
WH Vibrating Horn Signals are used:
SM87, XB11 and XB12 Status Lights are the most rugged and reliable status lights for harsh and hazardous applications.
The SM87 SL range is manufactured in marine grade alloy and the XB12 SL in corrosion-free GRP to provide a wide range of status lights to suit your requirements. Applications include:
FB11 UL Steady-On Beacons are UL Listed for Type 3R, 4X and marine installations. Typical industrial and commercial applications include food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, offshore oil rigs, water and filtration plants and chemical plants.
FEATURESFire Alarm or Emergency Call Points have been designed for use in hazardous locations and harsh environmental conditions. They offer:
HD1 Heat Detectors have been designed for use in hazardous environments. These units are suitable for fire alarm and/or suppression systems in offshore and onshore applications including paint spray booths, flammable material stores, turbine rooms, extract ductwork and other hazardous areas throughout the oil and gas, petrochemical and process industries.
FEATURES