Our Products
Lubricants
1 Products availableWe are leaders in the market for providing best range of Diesel Engine Oils, Manual Transmission Oils and Automatic Transmission Oils
Zeal Turbo Power 10W-30 CJ-4 is extra high performance diesel engine oil formulated with highly refined base stocks and advanced technology additives to provide reliable engine performance in the latest emission designs, including those with Exhaust Gas Recirculation (EGR) systems and after treatment systems with Diesel Particulate Filters (DPF) and Diesel Oxidation Catalyst (DOC), as well as satisfying the needs of older engines. It may be used in naturally aspirated and turbocharged diesel & petrol engines and On & Off highway applications, providing excellent protection even under the most strenuous conditions.
Zeal Turbo Power 10W-30 CJ-4 is extra high performance diesel engine oil formulated with highly refined base stocks and advanced technology additives to provide reliable engine performance in the latest emission designs, including those with Exhaust Gas Recirculation (EGR) systems and after treatment systems with Diesel Particulate Filters (DPF) and Diesel Oxidation Catalyst (DOC), as well as satisfying the needs of older engines. It may be used in naturally aspirated and turbocharged diesel & petrol engines and On & Off highway applications, providing excellent protection even under the most strenuous conditions.
Zeal Turbo Power 10W-30 meets or exceeds following International and Builder specifications:
Zeal Turbo Power | Test Meod | Units | 10W-30 |
---|---|---|---|
Density @ 15 0C | ASTM D 4052 | gm/cc | 0.870 |
Viscosity @ 100 0C | ASTM D 445 | cSt | 10.4 |
Viscosity @ 40 0C | ASTM D 445 | cSt | 62.6 |
Viscosity Index | ASTM D 2270 | - | 152 |
Pour Point | ASTM D 97 | °C | -36 |
Flash Point (COC) | ASTM D 92 | °C | 215 |
Total Base Number | ASTM D 2896 | mg KOH/g | 10.4 |
Sulfated Ash | ASTM D 874 | % wt | 1.0 |
CCS Viscosity | ASTM D 5293 | cP | 5550 @ -25 °C |
Zeal Syn Dura Maxx HD 75W90 GL-5 is a high performance heavy duty gear oil, formulated from high quality Synthetic Blend of base oils and an advanced additive system. These lubricants are designed for automotive heavy-duty transmissions, axles and final drives. Moreover these oils are specially engineered for heavy-duty axles and final drives where extreme pressures and shock loadings are expected.
Zeal Syn Dura Maxx HD 75W90 GL-5 is a high performance heavy duty gear oil, formulated from high quality Synthetic Blend of base oils and an advanced additive system. These lubricants are designed for automotive heavy-duty transmissions, axles and final drives. Moreover these oils are specially engineered for heavy-duty axles and final drives where extreme pressures and shock loadings are expected.
Zeal Syn Dura Maxx HD 75W90 GL-5 meets or exceeds following International and Builder specifications:
Zeal Syn Dura Maxx HD 75W90 GL-5 is suitable for use in all Passenger cars, On-highway light and heavy duty trucks, and commercial vehicles.
Zeal Syn Dura Maxx HD | Test Method | Units | 75W90 |
---|---|---|---|
Density @ 15 °C | ASTM D 4052 | gm/cc | 0.87 |
Viscosity @ 40 °C | ASTM D 445 | cSt | 125 |
Viscosity @ 100 °C | ASTM D 445 | cSt | 16.3 |
Viscosity Index | ASTM D 2270 | - | 139 |
Pour Point | ASTM D 97 | °C | -39 |
Flash Point (COC) | ASTM D 92 | °C | 222 |
Copper Strip Corrosion | ASTM D 130 | - | 1B |
Foam Seq I,II,III | ASTM D 892 | ml/ml | 10/0 |
Phosphorus | ASTM D 4951 | %wt | 0.055 |
Zeal Trans ATF TYPE A
1.Product Use: AUTOMATIC TRANSMISSION OIL
2.Synonyms: ECOLUBE ATF TYPE A
3.Company Identification
ZEAL INT LUBRICANTS IND L.L.C PO Box: 47480, Behind Khansaheb Building, Sharjah, UAE.
4.HAZARDS IDENTIFICATION
Emergency and Hazards OverviewCAUTION: Contains Petroleum Lubricant. Repeated skin contact can cause skin disorders.ATTENTION: Used motor oil is a possible skin cancer hazard based on animal data. Repeated exposure to oil mist in excess of the OSHA limit (5mg/m3) can result in accumulation of oil droplets in pulmonary tissue.
NFPA Ratings: Health 1 Flammability 1 Reactivity 0 Primary Route of Exposure: Skin X Inhalation -- Eye X Health Effect Information Eye Contact: This product is practically non-irritating to the eyes upon direct contact. Based on testing of similar products and/or components.
Skin Contact: Avoid skin contact. This product is minimally irritating to the skin upon direct contact. Based on testing of similar products and/or components. Prolonged or repeated contact may result in contact dermatitis which is characterized by dryness, chapping, and reddening. Prolonged or repeated contact may result in oil acne which is characterized by blackheads with possible secondary infection. Avoid prolonged and repeated skin contact with used motor oils. See Section 11 - Toxicological Information.
Inhalation: This product has a low vapor pressure and is not expected to present an inhalation hazard at ambient conditions. Caution should be taken to prevent aerosolization or misting of this product. On rare occasions, prolonged and repeated exposure to oil mist poses a risk of pulmonary disease such as chronic lung inflammation. Signs of respiratory effects vary with concentration and length of exposure and include nasal discharge, sore throat, coughing, bronchitis, pulmonary edema and difficulty breathing. Shortness of breath and cough are the most common symptoms.
Ingestion: Do not ingest. This product is relatively non-toxic by ingestion. This product has laxative properties and may result in abdominal cramps and diarrhea. Exposure to a large single dose, or repeated smaller doses, may lead to lung aspiration, which can lead to lipid pneumonia or chronic lung inflammation. These are low-grade, chronic localized tissue reactions.
Medical Conditions Aggravated by Exposure: Drying and chapping may make the skin more susceptible to other irritants, sensitizers and disease. Other: No information available
5. FIRST AID INFORMATION Eye Contact: Immediately flush eyes with large amounts of water and continue flushing until irritation subsides. If material is hot, treat for thermal burns and seek immediate medical attention. Skin Contact: No treatment is necessary under ordinary circumstances. Remove contaminated clothing. Wash contaminated area thoroughly with soap and water. If material is hot, submerge injured area in cold water. If victim is severely burned, remove to a hospital immediately. Inhalation: This material has a low vapor pressure and is not expected to present an inhalation exposure at ambient conditions. If vapor or mist is generated when the material is heated, and the victim experiences signs of respiratory tract irritation, remove to fresh air. Ingestion: No treatment is necessary under ordinary circumstances. Do not induce vomiting. If victim exhibits signs of lung aspiration such as coughing or choking, seek immediate medical assistance. Notes to Physician: No information available Other: No information available
6. FIRE AND EXPLOSION INFORMATION Flammable Properties Flash Point: 202C (typical) by Test Method: ASTM 92 Flammable Limits in Air Upper Percent: No data available Lower Percent: No data available Auto ignition Temperature: No data available Test Method: No information available NFPA Classification: Class III-B combustible liquid Extinguishing Media: Use dry chemical, foam, or carbon dioxide. Fire Fighting Measures Special Fire Fighting Procedures and Equipment: Water may be ineffective but can be used to cool containers exposed to heat or flame to prevent vapor pressure buildup and possible container rupture. Caution should be exercised when using water or foam as frothing may occur, especially if sprayed into containers of hot, burning liquid. Unusual Fire and Explosion Conditions: Dense smoke may be generated while burning. Carbon monoxide, carbon dioxide, and other oxides may be generated as products of combustion. Hazardous Combustion By-Products: None Other: No information available
7. ACCIDENTAL RELEASE MEASURES
Personnel Safeguards: Consult Health Effect Information in Section 3, Personal Protection Information in Section 8, Fire and Explosion Information in Section 5, and Stability and Reactivity Information in Section 10. Regulatory Notifications: Notify appropriate authorities of spill. Containment and Clean up: Contain spill immediately. Do not allow spill to enter sewers orWatercourses. Absorb with appropriate inert material such as sand, clay, etc. Large spills may be Picked up using vacuum pumps, shovels, buckets, or other means and placed in drums or other Suitable containers. Other: No information available
8. HANDLING AND STORAGE INFORMATION
Handling: Fire extinguishers should be kept readily available. See NFPA 30 and OSHA 1910.106-Flammable and Combustible Liquids. Storage: Do not transfer to unmarked containers. Store in a closed containers away from heat, sparks, open flame, or oxidizing materials. Empty Container Warnings Drums: Empty drums should be completely drained, properly bunged and promptly returned to a drum reconditioned, or properly disposed. Plastic: Empty container may retain product residues. Other: No information available
9. EXPOSURE CONTROLS / PERSONAL PROTECTION INFORMATION
Exposure Limits and GuidelinesThis product does not contain any components with OSHA or ACGIH exposure limits. Personal Protective Equipment Eye/Face Protection: Eye protection is not required under conditions of normal use. If material is handled such that it could be splashed into eyes, wear plastic face shield or splash-proof safety Goggles. Skin Protection: No skin protection is required for single, short duration exposures. For prolonged or repeated exposures, use impervious clothing (boots, gloves, aprons, etc.) over parts of the body subject to exposure. If handling hot material, use insulated protective clothing (boots, gloves, Aprons, etc.). Launder soiled clothes. Properly dispose of contaminated leather articles including Shoes, which cannot be decontaminated. Respiratory Protection: Respiratory protection is not required under conditions of normal use. If vapor or mist is generated when the material is heated or handled, use an organic vapor respirator with dust and mist filter. All respirators must be NIOSH certified. Do not use compressed oxygen in hydrocarbon atmospheres. Personal Hygiene: Consumption of food and beverage should be avoided in work areas where Hydrocarbons are present. Always wash hands and face with soap and water before eating, Drinking, or smoking. Engineering Controls / Work Practices Ventilation: If vapor or mist is generated when the material is heated or handled, adequate ventilation in accordance with good engineering practice must be provided to maintain concentrations below the specified exposure or flammable limits. Other: The OSHA permissible exposure limit (PEL) and ACGIH threshold limit value (TLV) for oil mist is 5 mg/m3. The ACGIH short-term exposure limit (STEL) for oil mist is 10 mg/m3.
10. PHYSICAL AND CHEMICAL PROPERTIES Appearance: Red Odor: Hydrocarbon - mild Vapor Pressure: No data available Physical state: Liquid Vapor Density (air=1): No data available PH: No data available Percent Volatile by Volume: No data available Boiling Point: No data available Volatile Organic Content: No data available Melting Point: No data available Molecular Weight: No data available Specific Gravity: 0.876 g/cc @ 60F / 60F Average Carbon Number: No data available Pour Point: Data Not Available, Viscosity @ 100F: No data available Viscosity @ 100C: 7.6 CST (Typical) Solubility in Water: Negligible in water Octanol / Water Coefficient: Log Kow = No data available
11. STABILITY AND REACTIVITY INFORMATION