Our product range contains a wide range of Volume Control Damper, Gi Volume Control Damper, Low Leakage Volume Control Damper, Pre-Insulated Volume Control Damper and Stainless Steel Volume Control Damper

Volume Control Damper

  • Frame High quality Galvanized Steel sheet of thickness 1.2mm as standard.
  • Frame size 125mm depth and standard flange height of 25mm.
  • Blades Double skinned high quality extruded Aluminium aerofoil profiles.
  • Drive shaft Electro-plated square rod of size 12.7mm x 12.7mm.
  • Bushings Self-lubricating nylon bushings.
  • Blade linkage Nylon gear. Handle: Galvanized Steel locking hand quadrant.
  • Blade stopper: G.l angle of thickness 0.7mm.
Product Description

Volume Controldamper is widely used in heating, ventilation and air-conditioning applications in order tomaintain or control the air volume inside the duct. These dampers facilitate the air flow to each zone and each room to be controlled during testing & commissioning. The blades may be parallel or opposed type dependingon the requirement.

Volume controldamper can be mounted either horizontally or vertically. However, care should be taken to mount the damper, by orienting the blades in the direction of the desired airflow. Airmaster provides several types of volume control dampers to choose from.

This model AVCD is the most commonly used model in majority of the projects

Description:

  • Airmaster Volume Control Dampers are specially designed for use in heating, ventilating and air conditioning systems.
  • Constructed from high quality G.I Sheets
  • Joints are welded and protected by aluminium spray coating to prevent rusting.
  • Blades are coupled by toothed nylon gears which provides opposed blade operation.
  • Hand locking quadrant is provided with clear open/close indication and three intermediate open positions (1/4 1/2 3/4).
  • Foam gasket is sealed across the blade edges to minimize air leakage between the blades.
  • Flanged edges are supplied un-drilled as standard.
  • Dampers without flanges available as option for duct insertion purpose refer Model AVCD-SC.

Optional Accessories:

  • Frame: Thickness up to 2mm on request.Aluminium frame available for light weightapplications.
  • Handle: Cast Aluminium.
  • Bush: Brass bush, S.S. Ball Bearing.
  • Gear Wheel: Aluminium Alloy.
  • Blade: Low leakage: S.S Jamb seal, Nylonblade end caps
View Complete Details

Gi Volume Control Damper

  • Frame High quality Galvanized Steel sheet of thickness 1.2mm as standard.
  • Frame Size: 125mm depth and standard flange height of 25mm.
  • Blades Single skinned 3-V type G.I blade of 1.5mm thickness.
  • Drive Shaft: Electro plated square rod of size 12.7mm x 12.7mm.
  • Bushings Self-lubricating nylon bushings.
  • Blade linkage: Nylon gear/mechanical linkage.
  • Blade stopper: G.I angle of thickness 0.7mm.
  • Handle Galvanized Steel locking hand quadrant.
Product Description

Volume Controldamper is widely used in heating, ventilation and air-conditioning applications (HVAC Damper) in order tomaintain or control the air volume inside the duct. These dampers facilitate the air flow to each zone and each room to be controlled during testing & commissioning. The blades may be parallel or opposed type dependingon the requirement.

Volume controldamper can be mounted either horizontally or vertically. However, care should be taken to mount the damper, by orienting the blades in the direction of the desired airflow. Airmaster provides several types of volume control dampers to choose from.

Airmaster G.I volume control damper is a type of HVAC Damper whose frame and blade is made of high quality G.I sheets.

Description:

  • Designed for use in heating, ventilating and air conditioning systems.
  • Both frame and blades are fabricated from high quality G.I sheets.
  • Joints are welded and protected by aluminium spray coating to prevent rusting.
  • Blades are coupled by toothed nylon gears which provides opposed blade operation.
  • Hand locking quadrant is provided with clear open/close indication and three intermediate open positions (1/4 1/2 3/4).
  • Foam gasket is sealed across the blade edges to minimize air leakage between the blades.
  • Flanged edges are suppliedun-drilledas standard.
  • Dampers without flanges available as option for duct insertion purpose.

Options:

  • Frame:Thickness up to 2mm upon request.
  • Blade:Double skin aerofoil type G.I blade of thickness 0.7mm.
  • Handle:Cast Aluminium.
  • Bush:Brass bush, S.S. Ball Bearing.
  • Gear Wheel:Aluminium Alloy.
  • Low Leakage:S.S Jamb seal.
View Complete Details

Low Leakage Volume Control Damper

Product Description

Volume Controldamper is widely used in heating, ventilation and air-conditioning applications in order tomaintain or control the air volume inside the duct. These dampers facilitate the air flow to each zone and each room to be controlled during testing & commissioning. The blades may be parallel or opposed type dependingon the requirement.

Volume controldamper can be mounted either horizontally or vertically. However, care should be taken to mount the damper, by orienting the blades in the direction of the desired airflow. Airmaster provides several types of volume control dampers to choose from.

Low Leakage Volume Control Damper are designed for use in heating, ventilating and air conditioning systems forlow-leakage applications.

Description:

  • Used in heating, ventilating and air conditioning systems forlow-leakage applications.
  • Joints are welded and protected by aluminium spray coating to prevent rusting.
  • Blades are coupled by toothed nylon gears which provides opposed blade operation.
  • Hand locking quadrant is provided with clear open/close indication and three intermediate open positions (1/4 1/2 3/4).
  • Foam gasket is sealed across the blade edges to minimise air leakage between the blades.
  • Flanged edges are suppliedun-drilledas standard.
  • Damper without flanges available as option for duct insertion purpose.
  • Air leakage from 0.18% to 1.33% only based on tests conducted in accordance with AMCA standard500-D-98.

Options

  • Frame:G.I sheet of thickness up to 2mm available upon request. Aluminium frame is also available for light weight / offshore / exposed area applications.
  • Handle:Cast Aluminium.
  • Bush:Brass bush, S.S. Ball Bearing.
  • Gear Wheel:Aluminium Alloy.
  • Low Leakage:S.S Jamb seal.
View Complete Details

Pre-Insulated Volume Control Damper

  • Frame 20mm thick polyurethane material with 2-sides Aluminium foil facing.
  • Frame Size: 200mm depth with flanges forside-fixing.
  • Baldes Double skinned high quality extruded Aluminium aerofoil profiles.
  • Drive Shaft: Electro plated square rod of size 12.7mm x 12.7mm.
  • Bushing Self-lubricating nylon bushings.
  • Blade linkage: Nylon Gear.
  • Blade stopper: G.I angle of thickness 0.7mm.
  • Handle Galvanized Steel locking hand quadrant.
Product Description

Volume Controldamper is widely used in heating, ventilation and air-conditioning applications (HVAC Damper) in order tomaintain or control the air volume inside the duct. These dampers facilitate the air flow to each zone and each room to be controlled during testing & commissioning. The blades may be parallel or opposed type dependingon the requirement.

Volume controldamper can be mounted either horizontally or vertically. However, care should be taken to mount the damper, by orienting the blades in the direction of the desired airflow. Airmaster provides several types of volume control dampers to choose from.

Airmaster Pre-Insulated volume control damper is made of high quality Pre-Insulated board for light weight applications. It is mainly used in places where pre-insulated ducts are used.

Description:

  • Designed for use in heating, ventilating and air conditioning systems in open/limited access areas and light weight applications.
  • The edges are joined using special glue and silicon.
  • Blades are coupled by toothed nylon gears which provides opposed blade operation.
  • Hand locking quadrant is provided with clear open/close indication and three intermediate open positions (1/4 1/2 3/4)
  • Foam gasket is sealed across the blade edges to minimize air leakage between the blades

Options:

  • Frame: Thickness up to 25mm available upon request.
  • Handle: Cast Aluminium.
  • Bush: Brass bush.
  • Gear Wheel: Aluminium Alloy.
View Complete Details

Stainless Steel Volume Control Damper

Product Description

Volume Controldamper is widely used in heating, ventilation and air-conditioning applications in order tomaintain or control the air volume inside the duct. These HVAC dampers facilitate the air flow to each zone and each room to be controlled during testing & commissioning. The blades may be parallel or opposed type dependingon the requirement.

Volume controldamper can be mounted either horizontally or vertically. However, care should be taken to mount the damper, by orienting the blades in the direction of the desired airflow. Airmaster provides several types of volume control dampers to choose from.

Stainless Steel Volume control Damper is used inoff shore, hospitals, laboratories, clean room and other special applications.

Description:

  • Designed for offshore applications in heating, ventilating andair-conditioningsystems.
  • Can also be used in chemical industries and kitchen ventilation.
  • Joints are welded and protected by chemical cleaning process.
  • Blades are coupled by toothed nylon gears which provides opposed blade operation.
  • Hand locking quadrant is provided with clear open/close indication and three intermediate open positions (1/4 1/2 3/4).
  • Foam gasket is sealed across the blade edges to minimize air leakage between the blades.
  • Flanged edges are suppliedun-drilledas standard.
  • Dampers without flanges available as option for duct insertion purpose.

Options:

  • Frame:Thickness up to 1.6mm upon request.
  • Gear Wheel:Aluminium Alloy.
  • Low Leakage:S.S Jamb seal.
View Complete Details

Slip & Clip Volume Control Damper

Product Description

Volume Controldamper is widely used in heating, ventilation and air-conditioning applications (HVAC Damper) in order tomaintain or control the air volume inside the duct. These HVAC dampers facilitate the air flow to each zone and each room to be controlled during testing & commissioning. The blades may be parallel or opposed type dependingon the requirement.

Volume controldamper can be mounted either horizontally or vertically. However, care should be taken to mount the damper, by orienting the blades in the direction of the desired airflow. Airmaster provides several types of volume control dampers to choose from.

Slip and Clip model HVAC Damper does not have flanges and are manufacturedwith cleats for ease of fixing into ducts for smaller sizes.

Description:

  • Designed for use in heating, ventilating and air conditioning systems.
  • Joints are welded and protected by aluminium spray coating to prevent rusting.
  • Blades are coupled by toothed nylon gears which provides opposed blade operation.
  • Hand locking quadrant is provided with clear open/close indication and three intermediate open positions (1/4 1/2 3/4).
  • Foam gasket is sealed across the blade edges to minimize air leakage between the blades.

Options:

  • Handle: Cast Aluminium.
  • Bush: Brass bush, S.S. Ball Bearing.
  • Gear: Wheel: Aluminium Alloy.
  • Low Leakage: S.S Jamb seal, Nylon blade end caps.
View Complete Details

Motorized Volume Control Damper

  • Frame High quality Galvanized Steel sheet of thickness 1.2mm as standard.
  • Frame Size 125mm depth and standard flange height of 35mm.
  • Blades Double skinned high quality extruded Aluminium aerofoil profiles.
  • Drive Shaft : Electro-plated square rod of size 12.7mm x 12.7mm.
  • Bushings Self-lubricating S.S Ball bearing.
  • Blade linkage Nylon gear.
  • Blade stopper G.I angle of thickness 0.7mm.
Product Description

Airmaster manufactures Motorized volume control damper for controlling the air flow through the damper remotely usingBMS system.

Description:

Designed for use in heating, ventilating and air conditioning systems.

Joints are welded and protected by aluminum spray coating to prevent rusting.

Blades are coupled by toothed nylon gears which provide opposed blade operation.

Foam gasket is sealed across the blade edges to minimize air leakage between the blades.

Flanged edges are suppliedun-drilledas standard.

Dampers without flanges available as option for duct insertion purpose.

Actuators of clients choice will be supplied separately.

Dampers will be provided with extended spindle to fix actuatoron-site.

Bigger sizes will be provided with mechanical linkage for stability andhassle-freeoperation.

Frame:Thickness up to 2mm upon request. Aluminium frame available foroff-shoreor light weight applications.

Handle:Cast Aluminium

Bush:Brass bush, S.S. Ball Bearing.

Gear Wheel:Aluminium Alloy.

Low Leakage:S.S.Jambseal, nylon blade end caps.

View Complete Details